Cutter bar oil change
Oil level in the cutter bar should be checked when the mower is set on flat ground. Unscrew the
oil filler plug (A, fig. 25). Oil level from the bottom of the bar should be between
5 ÷ 7mm.
Fig. 25 – filler plug (A) and drain plug (C)
To change the cutter bar oil:
-
Unscrew the filler plug (A)
-
Lift up the cutter bar
-
Unscrew the drain plug (C) – it is located on both sides of the cutting unit
-
Drain the oil to a container
-
Screw the drain plug
-
Lower the cutter bar to right level and fill in new oil (80W-90 GL-5), amount: 3 L
-
Screw the filler plug
Change the oil in the bevel gear unit and cutting bar after the first 50
operating hours. Further changes after 500 working hours or every year.
If you notice any leaks, it is essential to check the seal and the oil level. Operating the mower at
low oil levels can cause permanent damage to the mower. Any repairs of the cutting bar and
gear unit during the warranty period may only be carried out by a mechanical workshop
indicated by the manufacturer.
DANGER
Excessive oil level in the cutting bar may impair its operation and damage it
in the worst case.