background image

in contact with hot components of the appliance until they

have cooled down.

8.

To reduce the risks caused by 

exposure of oxalic acid:

Do not use in closed spaces

Use only in open spaces in a well ventilated area.

Do not breathe in vapours or oxalic acid powder.

Wear a whole body protection suit to avoid contact with 

vapours or oxalic acid powder, both when filling up the tank

and also during treatments.

Pay special attention to the handling of the oxalic acid.

Avoid direct contact of the oxalic acid with eyes, skin and 

respiratory tract.

Wear saftey glasses.Follow the instructions in

product designated manual.

Wear saftey gloves.

Follow the instructions in user manual.

Wear a protective mask for respiratory tract with

ABE/P3 filter or higher.

Follow the instructions in product user manual.

Be aware of wind direction during treatment so that the 

oxalic acid is not blown in the direction of anybody, 

including the person carrying out the treatment.

The treatment of bee colonies should happen only outside in

open spaces. During and after the treatment ventilate the 

hive well, nobody should remain in the apiary.

After the treatment, especially the winter treatment when 

the bees don’t clean like in summer, there may be some 

oxalic acid crystals inside the hive and on the bottom board.

Be careful and wear protective gear. 

Maintain the oxalic acid in it’s original packaging and in a 

safe place (with label in accordance with the law)

As a precaution- wash hands well after use. 

IN CASE OF  INGESTION

:

Contact an Antivenom centre or a doctor.

IN CASE OF CONTACT WITH EYES

Wash carefully for a few minutes. Remove contact lenses and 

keep washing and rinsing.

IN CASE OF CONTACT WITH SKIN

Wash thoroughly with water and soap.   

9. To reduce the risk of injury or work related accidents and 

illnesses other than those described previously: 

Do not use the device in dim lighting conditions. In case, use 

artificial light.

Clean the device exclusively with water and avoid water 

entering the handle and coming into contact with the 

thermic insulation .

The use of the product by professional operators that use  it

frequently, must be aware of factors that could increase the

risk of danger to the operators themselves. 

Do not leave the device unattended when it is switched on.

Do not leave the device nor the oxalic acid in places 

frequented by children and/or where children could reach. 

Handle the device exclusively through the handle, the 

knobs , the hammer and the caps, and the doser caps.

For further information on the use of oxalic acid, please 

refer to the technical and saftey manual of the oxalic acid 

itself. 

Considering the nature of the device, and its intended use, 

the dangers that derive specifically with the use of the  

OXALIKA PRO CORDLESS  vaporizer are added to the 

dangers involved in beekeeping . Faced with these dangers, 

the professional user will have to remedy after 

appropriately evaluating them as per applicable laws.

10.

To reduce the risk of damage

The dispenser tube reaches temperatures of approximately  

200 °C  and therefore could damage parts of the hive that come

into contact with it. Do not use on hives made of plastic or on 

plastic nets without adding the designated adapter around the 

dispenser tube.

II. Technical details and Functions

The oxalic acid is heated so as to make it evaporate when 

introduced inside the hive. This forms a fog that covers the 

bees and all the surfaces with a thin layer of oxalic acid crystals.

These small crystals are well tolerated by the bees, but have a 

lethal action on the varroa.

III. Treatment and Instructions of Use

This device is to be used soley for beekeeping purposes related 

to the vaporization of the oxalic acid intended for its use. 

The vaporizer OXALIKA PRO CORDLESS was designed and built 

to satisfy specific needs regarding the treatment against varroa 

of hives inhabited by bees. The vaporizer OXALIKA PRO 

CORDLESS is used against varroa when there is no brood, 

during the cold months of the year . Considering the elevated 

efficacy of the vaporizer  OXALIKA PRO CORDLESS (>96%), it is 

possible to reduce the population of varroa so that the bees are

in optimum condition for the next season. 

DOSE: 

For the hives, like dadant, the dose of oxalic acid is 2g for

medium colonies. The spoons, corresponds to 1g of acid. If 

after the treatment more than 1000 varroa are eliminated, or 

in the uncertainty of brood presence, it is necessary to repeat 

the treatment at a distance of 2 weeks from the first treatment 

with the same dose of 1g of acid regardless of the size of the 

colony. The swarms and artifical swarms can be treated 

throughout the year. The families with the queen must be 

treated before the capping of the broods. Warning : The 

orphan colonies react with a frenetic “ coming and going” of 

bees. For further information please see the instructions as 

provided in the oxalic acid (for bee keeping) information sheet. 

The device must be used exclusively on hives populated by 

bees , do not treat weak colonies or empty hives.

In case of any malfunctions and/or damages of parts of the 

vaporizer  OXALIKA PRO CORDLESS stop the use immediately 

and send it back to the producer for maintenance. 

Product Assembly

Without heating the device, screw the dispenser tube into the 

threaded hole on the heater and seal it by gripping it with pliers

in the zone of greatest diameter. 

To facilitate the process of removal and change of dispenser 

tube there is a lubricating substance on the threaded of the 

tube.

Correct use of OXALIKA PRO CORDLESS.

For correct use of OXALIKA PRO CORDLESS, please refer to the

summary videos available at this link:

Summary of Contents for OXALIKA PRO

Page 1: ...w oxalika com Istruzioni per l uso OXALIKA PRO Sublimatore Professionale Use instructions for OXALIKA PRO Professional Vaporizer Istrucciones de uso Vaporizador Profesional OXALIKA PRO Mode d emploi p...

Page 2: ...non vadano a toccare le parti calde dell apparecchio Non esporre il l apparecchio agli agenti atmosferici Se l apparecchio in particolare il manico si surriscaldano a causa dell esposizione diretta al...

Page 3: ...I Trattamento e modalit d uso Questo apparecchio da considerarsi esclusivamente per uso apistico per la vaporizzazione di acido ossalico adatto allo scopo Il sublimatore OXALIKA PRO CORDLESS stato pro...

Page 4: ...guidelines as illustrated below 1 Read all the instructions before using the device 2 Use the device only for it s intended purpose as described in this manual 3 Do not use on hives uninhabited by be...

Page 5: ...ally with the use of the OXALIKA PRO CORDLESS vaporizer are added to the dangers involved in beekeeping Faced with these dangers the professional user will have to remedy after appropriately evaluatin...

Page 6: ...gal representative Dr Matteo Tonietti Instrucciones de uso Vaporizador Profesional OXALIKA PRO CORDLESS L anse cuidadosamente las instrucciones antes de la utilizaci n NDICE de materias I Instruccione...

Page 7: ...e la colmena por eso es recomendable utilizar toda la longitud del cable El tratamiento de las colonias en una colmena debe hacerse s lo desde el exterior Durante y despu s del tratamiento ventile bie...

Page 8: ...una sustancia lubricante a la rosca del mismo Uso correcto de OXALIKA PRO CORDLESS Para el uso correcto de OXALIKA PRO CORDLESS consulte los v deos resumen disponibles en este enlace https www youtub...

Page 9: ...cuisson avec des parties du corps humides ne l utilisez pas pieds nus Assurez vous que les fils lectriques d autres appareils pr s du four ne restent pas en contact avec les pi ces chaudes du produit...

Page 10: ...ruches qui seront en contact avec celui ci Ne pas utiliser sur des ruches en plastique ou sur maillage plastifi sans appliquer un adaptateur pr vu cet effet autour du tube diffuseur II Caract ristique...

Page 11: ...o 21 A 57025 Piombino LI D clare que l vaporateur pour acide oxalique MOD LE OXALIKA PRO CORDLESS Est en conformit avec les directives 2011 65 EU ROHS 89 336 CEE Directives compatibilit lectromagn tiq...

Page 12: ...inweise in den jeweiligen Bedienungsanleitungen befolgen Tragen Sie eine Schutzmaske f r die Atemwege mit Filter ABE P3 oder h her Die Hinweise in den jeweiligen Bedienungsanleitungen befolgen Die Win...

Page 13: ...rrohr in die Gewindebohrung auf dem Heizkessel geschraubt und durch Ansetzen einer Zange im Bereich des gr ten Durchmessers festgezogen F r eine leichtere Entfernung und den Austausch des Verdampferro...

Reviews: