++ Description : Caller ID to be present to Remote Party.
++ Valid values : 30 chars long, a-z,A-Z,*,0-9,.,- , No spaces allowed.
++ Default value is VOIP-500
++ Note : This will be sent when CallerIDPresentation = 1
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
CallerID = VOIP-500
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
++ Field name : AudioCodec
++ Description : Preferred Audio Codec to be used for Outgoing Calls.
++ Valid values : AudioCodec = 1 - G.711 PCM A Law
++ AudioCodec = 2 - G.711 PCM u Law (Default Value)
++ AudioCodec = 3 - G.729a
++ AudioCodec = 4 - G.723.1a
++ Note : None
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
AudioCodec = 2
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
++ Field name : AEC
++ Description : Enable/Disable Acoustic Echo Cancellation.
++ Valid values : AEC = 1 - Enable (Default Value)
++ AEC = 0 - Disable
++ Note : None
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
AEC = 1
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
++ Field name : VAD_CNG
++ Description : Enable/Disable Voice Activity detection/generation of
++ Silence packets.
++ Valid values : VAD_CNG = 1 - Enable (Default Value)
++ VAD_CNG = 0 - Disable
++ Note : None
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
VAD_CNG = 1
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
++ Field name : AGC
++ Description : Enable/Disable Automatic Gain Control
++ Valid values : AGC = 0 - Disable (Default Value)
++ AGC = 1 - Enable
++ Note : None
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
AGC = 0
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
++ Field name : JitterBuffer
++ Description : Size of Jitter buffer (millseconds)
++ Valid values : 0 (Default Value), 30, 60, 90 , 120