  Summary List of Programming Codes 

 

Programming 
Code 

Then 
Enter 

Memory Slot 

Function Description 

0-20 digits 

#00 

Primary autodial phone number for pushbutton 

0-20 digits 

#01 

Secondary autodial phone number for pushbutton 

0-20 digits 

#02 

Third autodial phone number for pushbutton 

0-20 digits 

#03 

Fourth autodial phone number for pushbutton 

0-20 digits 

#04 

Fifth autodial phone number for pushbutton 

0-20 digits 

#05 

Autodial phone number for central station receiver line 

0-20 digits 

#06 

Autodial phone number for central station voice line 

0-20 digits 

 

#07 

Primary autodial phone number for Auxiliary Input 

0-20 digits 

 

#08 

Secondary autodial phone number for Auxiliary Input 

0-20 digits 

 

#09 

Third autodial phone number for Auxiliary Input 

6 digits 

#17 

Voice message/other options.  For further details, see 

Section 6.9, Voice 

Message Codes, p.16

[Default 001210] 

6 digits 

#18 

Timing/dialing options.  For further details, see 

Section 6.8, 

Timing/Dialing Codes, p.15

[Default 234721] 

6 digits 

#19 

Change the security code 

[Default 827827 or TAPTAP] 

0-20 digits 

#20 

Primary ID number for central station 

[Default no ID number set]

 

0-20 digits 

#21 

Secondary ID number for central station 

[Default no ID number set]

 

6 digits 

#23 

Talk-A-Lert ID number 

* * 

 

 

Add a 

*

 at any point of the dial string 

* # 

 

 

Add a 

#

 at any point of the dial string 

* 7 

 

 

Add 4-second pause at any point of the dial string 

[Enter No Digits] 

#00 through #06 

Clear autodial phone numbers 

* 0 

 

 

Diagnostic tones to check microphone/speaker operation 

* 1 

 

 

Enable the Talk-A-Lert ID number to be transmitted when the AOR Series 
Analog Station auto-answers an inbound call 

* 2 

 

 

Enable the Talk-A-Lert ID number to be transmitted when the remote side 
answers the call (i.e. an outbound call)

 

* 6 

 

 

Disable 

* 1

 and 

* 2

 

[Default] 

 

 

Disconnect or terminate

 

an active outbound call only (i.e. cannot 

terminate/disconnect inbound calls or programming mode calls) 

# 7 

 

 

Exit programming mode and disconnect 

# # # 

 

 

Reset to factory defaults 

NOTE: 

After each programming code, a double-beep indicates the code has been accepted.  Four (4) beeps 
indicate an error

—re-enter the code again. 

Summary of Contents for AOR Series

Page 1: ...otice Talk A Phone Talkaphone bAlert Scream Alert WEBS and WEBS Contact are registered trademarks of Talk A Phone LLC All rights reserved All other trademarks mentioned in this document or website are...

Page 2: ...Output 7 4 Speaker and Microphone Volume 8 5 Mode Configuration DIP Switches 9 6 Software Programming 10 Quick Programming Guide 10 Accessing Programming Mode 11 Security Code 12 Summary List of Progr...

Page 3: ...quality and will provide years of reliable service This manual will guide you through the installation of this product and provide comprehensive operating instructions Please read this instruction ma...

Page 4: ...should be performed by qualified personnel only in accordance with the National Electrical Code and other federal state and local statutes and building codes Using shielded cable is recommended to avo...

Page 5: ...or website are the property of their respective owners and does not imply or indicate any approval endorsement sponsorship or affiliation with such owners unless such approval endorsement sponsorship...

Page 6: ...rademarks of Talk A Phone LLC All rights reserved All other trademarks mentioned in this document or website are the property of their respective owners and does not imply or indicate any approval end...

Page 7: ...nless such approval endorsement sponsorship or affiliation is expressly indicated 3 Auxiliary Inputs Outputs All AOR Series Analog Station models include one 1 Auxiliary Input Some models are optional...

Page 8: ...ease or decrease the speaker volume please refer to the illustration below to determine how to adjust the speaker volume DIP Switches 1 and 2 are provided to configure a few audio detection modes as o...

Page 9: ...expressly indicated 5 Mode Configuration DIP Switches Mode Configuration DIP Switches 1 2 and 3 are provided to configure a number of modes as outlined below Mode Configuration DIP Switch Position Fun...

Page 10: ...aker are active 2 Enter the default security code 827827 or TAPTAP 3 Program the Primary Phone Number to dial 0 20 digits for phone number 00 For dialing a number on a POTS or PSTN telephone line i e...

Page 11: ...the case 2 Call into the AOR Series Analog Station 3 Enter the default security code 827827 or TAPTAP 4 The call station will output a double beep and enter programming mode any programming code s may...

Page 12: ...iliation with such owners unless such approval endorsement sponsorship or affiliation is expressly indicated Security Code When Mode Configuration DIP Switch 3 is in the ON position the AOR Series Ana...

Page 13: ...phone number for Auxiliary Input 0 20 digits 08 Secondary autodial phone number for Auxiliary Input 0 20 digits 09 Third autodial phone number for Auxiliary Input 6 digits 17 Voice message other optio...

Page 14: ...n dialing pagers or voice mail systems use 7 in the dial string where a pause is required Autodial Phone Numbers for the Auxiliary Input When a dry contact closure is provided to the Auxiliary Input t...

Page 15: ...time between talk and listen modes i e VOX switching time 1 0 1 seconds 2 0 2 seconds Default 3 0 3 seconds 4 0 4 seconds 5 0 5 seconds 6 0 6 seconds 7 0 7 seconds 8 0 8 seconds 9 0 9 seconds B Call L...

Page 16: ...o Digit Voice Message Delay Sets the amount of time required to elapse 1 99 seconds after dialing the phone number before the voice message plays Factory set to automatically start playing the voice m...

Page 17: ...s been met the dialing process stops and the AOR Series Analog Station hangs up When the lap counter is disabled default if the AOR Series Analog Station is programmed to dial the next number on ring...

Page 18: ...onfiguration DIP Switch 3 to the OFF position programming mode and activate the pushbutton The unit will then call Talkaphone Technical Support no matter if it is connected directly to a PSTN line or...

Page 19: ...of the physical location of the phone call through either the voice message or the information displayed in the Talk A Lert software when it decodes the DTMF ID number Once the ANSWERED LED is activa...

Page 20: ...proval endorsement sponsorship or affiliation is expressly indicated Answering a Call from the AOR Series Analog Station at the Remote Side 1 The telephone at the remote side answering point or receiv...

Page 21: ...itch 3 is set to the OFF position or reset the unit to factory defaults 2 I have made several mistakes in programming my phone and or I do not know what has been programmed into the unit Can I start o...

Page 22: ...ound noise or silence has been recorded The answering point remote side will hear this voice message before the unit establishes two way communication The unit does not hang up 1 The unit is not progr...

Page 23: ...same terms and conditions Warranty period for Area of Rescue Products is sixty 60 months under the same terms and conditions Warranty period for Intercommunication Products is twelve 12 months under...

Page 24: ...rade name and model causes harm to the telephone network the telephone company will notify you in advance that temporary discontinuance of service may be required However if advance notice is not prac...