WEBS-ZPS Zone Paging System Instructions 

 

Copyright © 2011 Talk-A-Phone Co.  All rights reserved. 

 
 Talk-A-Phone 

Co. 

• 7530 North Natchez Avenue • Niles, Illinois 60714-3804 

Page 4 of 7 

Phone 773.539.1100 • Fax 773.539.1241 • info@talkaphone.com • www.talkaphone.com

 

 

All prices and specifications are subject to change without notice. 

Talk-A-Phone, Talk-A-Lert, Scream Alert and WEBS are registered trademarks of Talk-A-Phone Co. 

 

For 

PBX Loop Start Trunk Configuration

, move the TELEPHONE INTERFACE SLIDE switches on the 

module to the positions shown in 

Figure 5 

(i.e. LS and TRUNK). The two center conductors of the RJ11 

cord are TIP and RING 48VDC and have a specific polarity. Plug one end of the cord into the Loop Start 
Trunk of the PBX and the other end into the TRUNK jack on the module. 

 

 

 

Figure 5.

 WEBS-ZPS (without 7-pin DIP switch) for a PBX Loop Start Trunk configuration. 

 

For 

PBX Ground Start Trunk Configuration

, move the TELEPHONE INTERFACE SLIDE switches on 

the module to the positions shown in 

Figure 6 

(i.e. GS and TRUNK). The two center conductors of the 

RJ11 cord are TIP and RING 48VDC and have a specific polarity. Plug one end of the cord into the 
Ground Start Trunk of the PBX and the other end into the TRUNK jack on the module. 

 

 

 

Figure 6.

 WEBS-ZPS (without 7-pin DIP switch) for a PBX Ground Start Trunk configuration. 

 

The second module should have all its SYS ID 4-pin DIP switches set to zero. Connect the 12VDC power 
supply to the module. Remove the switch lock and place the PROGRAM/RUN switch on the second 
module to the RUN position. Set the TALK BACK 3-pin DIP switch to the OFF position (to the left) for all 
the zones. Set the OUTPUT switch to LO PWR position. 
 
Locate the terminals labeled ZONE A and connect them to the 

WEBS-MT/R

 tower. Each 

WEBS-MT/R

 

tower is allocated to a single zone on the 

WEBS-ZPS

. Zone A will be Zone 1 and can be paged by 

following the directions in 

Section VI 

of this manual.  Zone B will be Zone 2, Zone C will be Zone 3, and 

Zone A of the next module will be Zone 4, etc. Follow the same procedure for the remaining zones.  Refer 
to 

Figure 7(a) 

or

 7(b)

, to connect the 

WEBS-ZPS

 to the WEBS-MT/R Amplifier (black chassis) or the 

WEBS-MT/R Amplifier (silver chassis) respectively. 

Summary of Contents for WEBS-ZPS

Page 1: ...groups of zones up to 32 or all zones at once II Contents Before beginning installation make sure you have all the included components The WEBS ZPS includes Qty Part 1 WEBS ZPS 1 AC Adapter III Mount...

Page 2: ...pin DIP switch TEL INT SEL As shown in Figure 2 take the telephone cord from the interface system and wire it to the RJ11 TEL LINE jack to pins 3 and 4 red and green Use a 4 or 6 pin modular cord to c...

Page 3: ...INT SEL as shown in Figure 3 please refer to the following set of instructions Figure 3 WEBS ZPS without 7 pin DIP switch TEL INT SEL Use a modular RJ11 telephone cord minimum 2 conductor to connect t...

Page 4: ...e GS and TRUNK The two center conductors of the RJ11 cord are TIP and RING 48VDC and have a specific polarity Plug one end of the cord into the Ground Start Trunk of the PBX and the other end into the...

Page 5: ...773 539 1241 info talkaphone com www talkaphone com All prices and specifications are subject to change without notice Talk A Phone Talk A Lert Scream Alert and WEBS are registered trademarks of Talk...

Page 6: ...ted to the WEBS ZPS or by dialing the paging access number for the telephone system Programming Zone Groups 1 Dial the paging access number for your telephone system 2 The WEBS ZPS will emit 3 beep to...

Page 7: ...double beep 3 Dial the number of the zone you wish to page All dialing must be two digits For example 0 1 for zone 1 Zone A of the first zone module 0 2 for zone 2 etc If a zone number does not exist...

Reviews: