Zone Paging System Programming  

 
1.  To switch to programming mode, remove the switch lock and place the PROGRAM/RUN switch to 

PROGRAM position. In the case of a 

WEBS-ZPS 

unit without a 7-pin DIP switch (TEL INT SEL) on 

the first module, all programming is accomplished through the TRUNK jack on the first module, using 
the appropriate installed interface. To simplify initial programming, it is suggested that you change the 
interface type to loop start trunk as shown in 

Figure 5

 and connect a single-line telephone to the 

TRUNK jack. Once initial programming is completed, re-select the proper interface type and connect 
the access line. 

2.  The third, fourth, and fifth modules (zone modules) are not changed during programming. 
3. Access 

the 

WEBS-ZPS

 system by either going off-hook with a single line telephone connected to the 

WEBS-ZPS

 or by dialing the paging access number for the telephone system. 

 

Programming Zone Groups 

1.  Dial the paging access number for your telephone system.

 

2. The 

WEBS-ZPS

 will emit 3 beep tones, indicating access to the programming mode.

 

3. Dial

 [*]

 followed by the 2-digit number of the zone group (01-32) you want to create.  Follow this with 

the two-digit numbers of the zones you want to be in the zone group.  To save the data press 

[#]

  Example: 

 

If you want to create zone group 7 consisting of zones 2, 3, and 12, you would dial: 

  [*][0][7][0][2][0][3][1][2][#]. 

4.  When finished programming return the PROGRAM/RUN switch to RUN.   

 

 
To Erase a Zone Group 

1.  Dial the paging access number for your telephone system.

 

2. The 

WEBS-ZPS

 will emit 3 beep tones, indicating access to the programming mode.

 

3. Press 

[*]

 and the 2-digit zone group number you wish to erase and then press 

[#]

4.  When finished programming return the PROGRAM/RUN switch to RUN.   

 

To Disable the 30-Second Paging Time Out and 6-Second VOX Feature 

1.  Dial the paging access number for your telephone system.

 

2. The 

WEBS-ZPS

 will emit 3 beep tones, indicating access to the programming mode.

 

3. Dial 

05000# 

4. Dial 

0510#

 

5.  If the system accepts the code, you will hear a short double beep.  Otherwise if the code is not 

accepted, you will hear a busy tone.  If the code is not accepted, hang up, re-access the system and 
try again.

 

6.  Hang up the phone and place the PROGRAM/RUN switch in the RUN position.  

 
 

Summary of Contents for WEBS-ZPS

Page 1: ...groups of zones up to 32 or all zones at once II Contents Before beginning installation make sure you have all the included components The WEBS ZPS includes Qty Part 1 WEBS ZPS 1 AC Adapter III Mount...

Page 2: ...pin DIP switch TEL INT SEL As shown in Figure 2 take the telephone cord from the interface system and wire it to the RJ11 TEL LINE jack to pins 3 and 4 red and green Use a 4 or 6 pin modular cord to c...

Page 3: ...INT SEL as shown in Figure 3 please refer to the following set of instructions Figure 3 WEBS ZPS without 7 pin DIP switch TEL INT SEL Use a modular RJ11 telephone cord minimum 2 conductor to connect t...

Page 4: ...e GS and TRUNK The two center conductors of the RJ11 cord are TIP and RING 48VDC and have a specific polarity Plug one end of the cord into the Ground Start Trunk of the PBX and the other end into the...

Page 5: ...773 539 1241 info talkaphone com www talkaphone com All prices and specifications are subject to change without notice Talk A Phone Talk A Lert Scream Alert and WEBS are registered trademarks of Talk...

Page 6: ...ted to the WEBS ZPS or by dialing the paging access number for the telephone system Programming Zone Groups 1 Dial the paging access number for your telephone system 2 The WEBS ZPS will emit 3 beep to...

Page 7: ...double beep 3 Dial the number of the zone you wish to page All dialing must be two digits For example 0 1 for zone 1 Zone A of the first zone module 0 2 for zone 2 etc If a zone number does not exist...

Reviews: