4
Fig. 1. AEOLUS-SENSE PRO image.
It is important for the AEOLUS-SENSE PRO to be mounted parallel and as close as possible
to the symmetry axes of the airplane (see Fig. 2). The front side of the AEOLUS-SENSE PRO
is marked by a small airplane on the cover of the unit. After mounting the AEOLUS-SENSE
PRO, the “AHRS leveling” procedure described in Section 1.5 of the current manual should be
performed, in order to adjust for small inaccuracies during placement.
(a)
(b)
Fig. 2. AEOLUS-SENSE PRO should be mounted parallel to the main axes of the airplane.
1.2 Power Connection
AEOLUS-SENSE PRO is powered by two means:
•
Its internal battery, offering approximately one and half (1.5) hours of operation. Please
turn the battery-switch on for battery device operation.
•
The connections to the external DSUB25 connector are as in the below table:
•
PIN
CONNECTION
1
Main Power plus(+) (factory connected)
2
Autopilot
4
External USB(factory connected)
5
External USB(factory connected)
7
Horn red
8
External LED
9
temperature probe blue or yellow(factory connected)
10
GND
11
External Switch
12
External Switch
13
GND
21
temperature probe black (factory connected)
22
temperature probe red (factory connected)
24