It is important for the  AEOLUS-SENSE PRO  to be mounted parallel and  as close as possible 
to the  symmetry axes of the airplane (see Fig. 2).  The front side of the AEOLUS-SENSE PRO 
is marked by a small airplane on the cover of the unit. After mounting the AEOLUS-SENSE 
PRO, the “AHRS leveling” procedure described in Section 1.5 of the current manual should be 
performed, in order to adjust  for small inaccuracies during placement. 

 

 

 

(a) 

(b) 

Fig. 2. AEOLUS-SENSE PRO should be mounted parallel to the main  axes of the airplane. 

 

 1.2 Power Connection

 

 

AEOLUS-SENSE PRO is powered by two means: 

 

 

Its internal battery, offering approximately one and half (1.5) hours of operation. Please 
turn the battery-switch on for battery device operation.  

 

The connections to the external DSUB25 connector are as in the below table: 

 

PIN            

CONNECTION 

 

 

Main Power plus(+) (factory connected) 

 

 

Autopilot 

 

4    

 

External USB(factory connected) 

 

 

External USB(factory connected) 

 

 

Horn red 

 

 

External LED 

 

 

temperature probe blue or yellow(factory connected) 

 

10 

 

GND   

 

11   

 

External Switch 

 

12  

 

External Switch 

 

13 

 

GND 

 

21 

 

temperature probe black (factory connected) 

 

22 

 

temperature probe  red (factory connected) 

 

24 

 

Horn Black 

Summary of Contents for AEOLUS-SENSE PRO

Page 1: ...operation Please read the current manual prior to using AEOLUS SENSE PRO and keep it for future reference Correct operation of the AEOLUS SENSE PRO requires that one or more mobile smart device s iOS or Android are connected to the device ΑTTENTION We update the application EFIS TA and the firmware of our units when necessary to ensure the best performance of our devices This procedure is automati...

Page 2: ...US SENSE PRO 3 1 2 Power Connection 4 1 3 Software EFIS TA app 5 1 4 Compass Calibration 7 1 5 AHRS Leveling 8 1 6 Other Considerations Regarding the AEOLUS SENSE 4 T ADS B 9 2 AEOLUS SENSE PRO Maintenance 10 3 Use Limitations and Abnormal Operation 10 Support 10 ...

Page 3: ...ig 1 should be mounted in a convenient dry place as far away as possible from heat sources A suitable mounting location is the top of the instrument panel You can mount the unit by means of double sided adhesive tape or Velcro Please ensure that the unit doesn t move during flight Must be connected to the native pitot static using two 1 8in BSP to your hoses adaptors The AEOLUS SENSE PRO comes tog...

Page 4: ...ounted parallel to the main axes of the airplane 1 2 Power Connection AEOLUS SENSE PRO is powered by two means Its internal battery offering approximately one and half 1 5 hours of operation Please turn the battery switch on for battery device operation The connections to the external DSUB25 connector are as in the below table PIN CONNECTION 1 Main Power plus factory connected 2 Autopilot 4 Extern...

Page 5: ...O will continue its operation after a short reboot please make sure you reconnect to the AEOLUS SENSE PRO WiFi network Please note that in the latter case i e power failure and operation on the internal battery tethered connection see below section 1 3 paragraph USB Cable Connection to the smart mobile device smartphone or tablet will not work and you must enable the wifi connection Important Note...

Page 6: ...o power failure battery switch in off position EFIS TA app switches automatically to standalone mode and the message reappears Accordingly the pilot may continue using EFIS TA app with the internal sensors of the smart mobile device as a backup even in case of power failure From the main screen of the EFIS TA app interface you can tap on MENU button and navigate to sensor status window and check t...

Page 7: ...nection AEOLUS SENSE PRO creates a wifi network that is used to connect a smart mobile device The SSID of AEOLUS SENSE PRO wifi network is AEOLUS XXXXXXXXX where X is a unique alphanumeric string Up to ten 10 smart mobile devices can be simultaneously connected via wifi to an AEOLUS SENSE PRO 1 4 Compass Calibration Before start using your AEOLUS SENSE PRO the device s compass should be calibrated...

Page 8: ... seconds until the calibration window closes automatically a b c Figure 4 a Press Start to start compass calibration b Calibration in progress The calibration results are indicated as Weak you should continue rotating your device until you have a Good or Strong indication c Indication as Strong calibration signifies that the device s compass has been properly calibrated Fig 5 To easily calibrate t...

Page 9: ...ice iOS or Android to the AEOLUS SENSE PRO wifi Network Start the EFIS TA app on your mobile device Tap on MENU button and then Level AHRS EFIS TA app will return back to the main screen and the AHRS leveling window Fig 6 will appear Press the Auto button for automatic AHRS leveling and or use the arrows to manually adjust the AHRS Manual adjustment may be unavoidable if for example you are instal...

Page 10: ...llows Temperature range 20C to 65C or 4F to 149F Operation Voltage 10 32Vdc Operation Current for model 4 ADS b 0 5A for model 4T ADS B max 4A during tablet charging Please use a fuse of 10A Inflight power reset in case of inflight power reset or if you turn on the unit during the flight after losing your main systems please note that there is no limitation or constraint of attitude for correct op...

Page 11: ... For support via email please contact support talosavionics com For voice support please call USA 1 309 874 4227 Europe 30 2815 304480 For general questions feedback please contact info talosavionics com ...

Reviews: