55
6
7
21
25
42
44
45
47
N1
22
N2
G
G
G
G
G
N1
N1
N1
42
JUCTION BOX ON GLYCOL TANK
*
TO AQUASTAT
TO CIRC. PUMP
TO FIELD PUMP
TO COMPRESSOR
TO LOW LEVEL
TO BURNER
IGNITOR
MOTOR
VALVE
- IGNITOR
L2
L2
L2
L2(VALVE)
MOTOR
LIMIT
VALVE
TO JUNCTION
TO AQUASTAT
BURNER ASSEMBLY
M
M
21
N1
CIRCULATION PUMP
22
N2
FIELD PUMP
6
42
PRESSURE SWITCH
45
N1
COMPRESSOR
42
N1
LOW LEVEL
7
47
2
AQUASTAT
TO JUNCTION
ON GLYCOL TANK
TO LIMIT ON PRIMARY
CONTROLLER FOR BURNER
25
TO REAR
CONTROL PANEL
WHITE
WHITE
WHITE
WHITE
ORANGE
RED
PUMP PLATE WIRING DIAGRAM
CADCELL
CELL
CAD
TO PRESSURE SWITCH
TO P2 ON LOW LEVEL SWITCH
TO CIRCULATION PUMP
TO FIELD PUMP
TO PRESSURE SWITCH
TO 1 ON LOW LEVEL SWITCH
RED TO BURNER
TO COMPRESSOR
TO A ON LOW LEVEL SWITCH
TO COMPRESSOR
TO CIRC. PUMP
TO BURNER
TO 2 ON LOW LEVEL
"*" CONNECTION IN BURNER THEN THROUGH TO AQUASTAT
ON GLYCOL TANK
TO JUNCTION
ON GLYCOL TANK
TO JUNCTION
ON GLYCOL TANK
TO JUNCTION
ON GLYCOL TANK
TO JUNCTION
ON GLYCOL TANK
TO JUNCTION
ON GLYCOL TANK
1
P1
P2
A
TO FIELD PUMP
44
N1
GREEN
D
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
E
F
E
F
DRAWN
CONFIDENTIAL PROPERTY OF
11-JUL-2019
PP
11-JUL-2019
PP
Third Angle Projection
SHEET 3 OF 3
CHECKED
DATE
Indicate Critical Dimension
Unit of Measurement is Inch
-
0
1:5
Tamarack Industries reserves proprietary rights on this drawing
or any part of the information
contained thereon.This drawing shall be considered confidential
material and is not to be used for
competitive bidding or for use in any procurements other than f
rom Tamarack Industries.
UNLESS OTHERWISE SPECIFIED :
X.X
.1
X.XX
.02
X.XXX
.005
Fractions
1/32
Bend Rad = Thk
REV.
FINISH
MATERIAL
SCALE
DESIGNED
INITIALS
SCHEMATICS,ELECTRICAL
HK300
C
PART #
SIZE
448541