English
LD-G-11 / LD-W-11
Page 44
CV-no. Range of values Factory settings Remarks
1
1, 2, 3 ... 255
78
Address
2
1, 2, 3 ... 80
LD-G-11: 4
LD-W-11: 48
Starting velocity
3
1, 2, 3 ... 80
4
Acceleration delay
4
1, 2, 3 ... 80
4
Braking delay
5
1, 2, 3 ... 63
LD-G-11: 52
LD-W-11: 63
Maximum velocity
6
2(off), 3(on)
3 (on)
Analogue mode
7
Only internal importance.
Do not enter new values
for this CV.
8
4, 5, 6 ... 255
255
Motor frequency *
(only for LD-W-11)
9
100 ... 200
150
Analogue voltage needed
for change of direction
10-15
Not used
16-43 0 ... 255
Velocity table for velocity
characteristic. You can
assign an individual motor
voltage to each of the 27
speed levels.
44-47
Not used
48
1, 2, 3 ... 80
64
Lowest value of load
control parameters *
(only LD-G-11)
49
48, 49 ... 255
160
Highest value of load
control parameters *
(only LD-G-11)
* Proceed in small steps when altering the CV#8, #48 und #49. For