FAQ
§
Parts are getting too hot and/or start to smoke.
Disconnect the system from the mains immediately!
Possible cause: One or more connections are soldered incorrectly.
à
Check the connections.
Possible cause: The connection of the motor is connected to locomotive
ground.
à
Disconnect the connection from locomotive ground.
§
A lamp flickers (this is not a defect).
Possible cause: The lamp is connected with one side to locomotive ground.
à
If you do not want the lamp to flicker, disconnect it from
locomotive ground, insulate it and connect it to the return
conductor (point X4).
§
The locomotive runs too fast or too slow.
Possible cause: Different locomotives drive differently with the same
decoder settings.
à
Adjust the decoder settings to the individual
driving characteristics of the locomotive.
§
The locomotived does not react to F3 or F4.
Possible cause: The central unit is set to Motorola I format.
à
Set
the central unit to Motorola-II format.
§
The locomotive does not run in analogue mode.
Possible cause: The analogue mode is switched off.
à
Alter the value
for CV #6.
Possible cause: The analogue model railway layout is run with a D.C.
speed control; the analogue mode however is only possible with
A.C. speed controls.
§
After programming the decoder the locomotive does not run or runs
badly.
Possible cause: The set values for the CV are inconsistent.
à
Perform a decoder reset and program the decoder anew.