- 26 -
8.2.7 Replacing the glow lamp for the fluorescent lamp
1) Remove the back or right plate of the main unit.
2) There is a power box for the fluorescent lamp at
the back of the bath. Replace the glow lamp on
its side. The lamp screws in. (See Fig 034)
8.2.8 Replacing the light guide (optical fiber)
Note: The bath need not be removed from the main unit.
1) Remove the front plates (upper and lower) at
the top of the bath.
2) Remove the light guides from the optical
projector/receiver panel.
3) Unscrew the setscrews on the top plate of the
light guide holder from the top lid of the bath
and remove the light guide holder.
4) Replace the light guide. Do not fasten the
setscrew at the mouthpiece of the light guide
too hard. Make sure that the light guide does
not extend beyond the metal fixture inside the
bath. (See Fig. 35)
5) Make sure that the bundling does not bend the light guide excessively.
Fig. 34 Glow Lamp
Fig. 35 Light Guide