Operating the Equipment Locally
Page 4-68
Instruction Manual: evolution 5000 E5710 and E5720 Encoder
ST.TM.E10074.1
Bit-rate
RS422 Data Bit-rate :
+
56 kbit/s
—
Enter
l
Update using softkeys
Quit
l
Table 4.59: Bit-rate Options
Selected Option
Description
Settings cycle from 56 to 1792 in steps of 56 then from 64 to
2048 in steps of 64, then back to 56
RS-422 synchronous data
channel bit-rate.
RS422 PID Option
The RS422 PID option is selected from the
Data B - RS422
Menu
by
pressing the RS422 PID softkey. The option is used for entering or
updating data PIDs. Enter a PID using the softkeys, then press the Enter
softkey to accept it
To be DVB compliant, PIDs below 32 are reserved. Therefore PIDs 32 to
8191 are available for use. In the event of a clash, one of the PIDs will be
changed by the Encoder’s internal checking algorithm.
RS422 PID
¬
Left
RS422 Data PID :
+
®
Right
`261 (0105h)’
—
l
Ins
Enter
l
l
Del
Update using softkeys
Quit
l
Test Mode Option
The Test Mode option is selected from the
Data B - RS422
Menu
by
pressing the Test Mode softkey. The option is used for turning the test
mode On and Off.
SNMP oid index Option
The SNMP oid
7
index option is selected from the
Data B - RS422
Menu
by
pressing the SNMP oid index softkey.
All option modules have the same SNMP oid with the exception of one byte
which identifies which slot the module is in. An MEM expects the data
module to be in slot two or three in the previous Encoder. Therefore, slots
one and two in this Encoder have been allocated to correspond directly to
slots two and three in the previous Encoder.
In this Encoder the data module can be allocated to slot one, making it
inaccessible to an MEM. This variable allows the on-board data module to
be apparently moved around - to a slot in which it may be referenced by
the MEM.
7
oid = object identifier.