Technical Description of TANDBERG MCU with software version D3
D12925 Rev. 03
18
4.1.7.1 MCU Capacity – typical scenarios
In the table below some typical capacity scenarios are listed (they can be derived by the
calculation above):
Bandwidth
Non-encrypted
(Max. no. of video
sites + telephone
sites)
IP & E1
Non-encrypted
(Max. no. of video
sites + telephone
sites)
T1 only
Encrypted
(Max. no. of video
sites)
128 kbps
16 + 16
16 + 16
14
256 kbps
16 + 15
16 + 15
13
384 kbps
16 + 9
15 + 2**
11
512 kbps
15 + 0*
11 + 4**
10
768 kbps
10 + 0*
7 + 8**
7
1472 kbps
(1.5Mbps)
5 + 5
4 + 0**
N/A
1920 kbps (2Mbps) 4 + 0*
3 + 2**
N/A
*) Limited by the maximum capacity 7680 kbps, see
rule II a)
above.
**) Limited by the maximum capacity 5888 kbps, see
rule II b)
above
4.1.8 Dial
Profiles
The TANDBERG MCU can be programmed to use different Dial Profiles. Dial Profile consists
of a name and a prefix.
Example:
If 0 (zero) is needed to call outside a location, create a prefix called ‘external’ with prefix set to
0.
Also, to differentiate between ISDN numbers/E.164 Alias the ‘Dial Profiles’ shall be extended
to support selection of ‘ISDN’ & ‘H.323’.