TANDBERG MPS API
User Guide
28
Sequence notation
<command-type root command> <command> <value> <value>...
When using this notation the parameter values must be entered in the sequence as stated in
the help text:
Example 2.16
xcommand dial 666 10 128 on
Combination
A combination of mark-up notation and sequence are also supported. The marked parameters
will be assigned the user entered values first, and then the system will assign the sequence
entered parameters for the parameters not yet having been assigned a value:
Example 2.17
xcommand dial 666 r:on 10 128
Command response
When issuing a command, the system will return a set of return values, ref. the documentation
of the TANDBERG XML API. The response will be on the same format as the standard XACLI
Status format.
Example 2.18
xcommand dial 10.47.15.127
*r Result (status=OK):
CallRef: 1
LogTag: 6
*r/end
OK
NOTE!
When using XACLI as a machine-machine interface it is recommended to use markup
notation and always supply complete tag names.