File Transfer Protocol (FTP)
Page 9-4
Reference Guide: SM6610, SM6615, SM6620 and SM6625 Satellite Modulators
ST.RE.E10152.2
ftp> dir
200 Set port to 172.17.225.20:1143.
150 opening data connection
drw-rw-rw- 1 system system 0 FEB 26 11:48 software
drw-rw-rw- 1 system system 0 FEB 26 11:48 logs
drw-rw-rw- 1 system system 0 FEB 26 11:48 config
drw-rw-rw- 1 system system 0 FEB 26 11:48 dpc
drw-rw-rw- 1 system system 0 FEB 26 11:48 firmware
drw-rw-rw- 1 system system 0 FEB 26 11:48 webserver
drw-rw-rw- 1 system system 0 FEB 26 11:48 keys
226 transfer complete.
ftp: 469 bytes received in 0.02Seconds 29.31Kbytes/sec.
ftp>
The format of the dir results reflect the FTP specification. The User is the
name of the user that last changed the file, or system for fixed or read-
only files and directories.
The group is used to indicate the version number of the file, or one of the
following for files that have no version:
cfg - Configuration
file
log - Log
file
9.1.3 The
Software
Directory
This directory contains the software for the Modulator. To enter the
software directory type cd /software.
ftp> cd /software
250 software/
ftp> dir
200 Set port to 172.17.225.20:1146.
150 opening data connection
--w--w--w- 1 root V02.00 1139209 JAN 28 12:56 active_app.hex
--w--w--w- 1 root V01.00 68661 APR 23 10:39 monitor.hex
--w--w--w- 1 system system 0 FEB 26 11:48 minapp.hex
--w--w--w- 1 root V02.00 1139209 JAN 28 16:51 app.hex
--w--w--w- 1 system s13129 999999 MAY 20 07:38 boot.hex
--w--w--w- 1 system s13129 999999 MAY 20 07:38 ctl.hex
226 transfer complete.
ftp: 423 bytes received in 0.03Seconds 13.65Kbytes/sec.
ftp>
The file active_app.hex is the current main application code for the
Modulator. Monitor.hex is the start up code for the Host Controller card.
Minapp.hex is the reduced application code (not currently supported).
App.hex is the backup application code. Boot.hex is the boot code for the
Baseband card, and ctl.hex is the Baseband control code.
NOTE…
The contents of this directory depend on the user’s access rights and the specific Modulator model.
It is not possible to retrieve software files from the Modulator.