File Transfer Protocol (FTP)
Reference Guide: SM6610, SM6615, SM6620 and SM6625 Satellite Modulators
Page 9-5
ST.RE.E10152.2
9.1.4
The Firmware Directory
This directory contains data which is loaded into the FPGA devices within
the Modulator. To enter the firmware directory type cd /firmware. Typical
firmware directory contents are as follows:
ftp> cd /firmware
250 firmware/
ftp> dir
200 Set port to 172.17.225.20:1147.
150 opening data connection
--w--w--w- 1 system s13129 999999 MAY 20 07:41 dsp.hex
--w--w--w- 1 system s13129 999999 MAY 20 07:41 coeff20.hex
--w--w--w- 1 system s13129 999999 MAY 20 07:41 coeff25.hex
--w--w--w- 1 system s13129 999999 MAY 20 07:41 coeff30.hex
--w--w--w- 1 system s13129 999999 MAY 20 07:41 coeff35.hex
226 transfer complete.
ftp: 356 bytes received in 0.09Seconds 3.79Kbytes/sec.
ftp>
The above files are firmware files for the Modulator Baseband Card.
9.1.5 The
Logs
Directory
This directory contains the logs kept by the Modulator. These are the same
logs as those viewed on the terminal described in Chapter 3, Operating the
Equipment Locally.
ftp> cd /logs
250 logs/
ftp> dir
200 Set port to 172.17.225.20:1148.
150 opening data connection
-rw-rw-rw- 1 system log 46489 MAY 20 07:31 event.log
-rw-rw-rw- 1 system log 14665 MAY 20 06:50 alarm.log
-rw-rw-rw- 1 system log 201 MAY 20 07:42 temp.log
226 transfer complete.
ftp: 209 bytes received in 0.41Seconds 0.51Kbytes/sec.
ftp>
The file event.log is the Event log, alarm.log is the Alarm log and
temp.log is the Temperature log.
NOTE…
The data for these logs is held in a compressed format, and when viewing a directory the logs are
uncompressed to calculate the file size which may take a few seconds.
Log files may be retrieved by using the get command.
ftp> get event.log
200 Set port to 172.17.225.20:1149.
150 opening data connection
226 Transfer complete.
ftp: 46489 bytes received in 0.94Seconds 49.61Kbytes/sec.