Licence Keys
Page 10-4
Reference Guide: SM6610, SM6615, SM6620 and SM6625 Satellite Modulators
ST.RE.E10152.2
A single key can enable more than one feature, but will only work on a
single Modulator. When keys are ordered for several Modulators a number
of keys may be supplied as a single licence key file.
10.3 Entering Single Licence Keys
10.3.1 Single
Key
When a single key is requested, it may be entered via the FTP interface.
10.3.2 FTP
Entry
Save the emailed key to a file called licence.dat and download to the keys
directory. An example session is shown as follows:
C:\>ftp 192.168.55.3
Connected to 192.168.55.3.
220 TANDBERG Satellite Modulator SM6600
User (192.168.55.3:(none)): root
331 Password required for user root.
Password:
230-Modulator identity:
230-DEV001
230 User logged in.
ftp> cd keys
250 keys/
ftp> put licence.dat
200 Set port to 172.17.225.20:1356.
150 opening data connection
226-DPC:Disabled
226-8PSK:Enabled
226-16QAM:Enabled
226-High Speed:Enabled
226-Low Speed:Enabled
226 Transfer complete.
ftp: 90 bytes sent in 0.00Seconds 90000.00Kbytes/sec.
ftp> bye
221 Closing connection ... goodbye.
10.4 Entering Multiple Licence Keys
The process of entering several keys is the same as for a single key.
Entering keys intended for several Modulators to a single unit does not
cause a problem as keys intended for other Modulators are ignored.
For example, if a system consists of 10 Modulators and they are all to be
upgraded to include higher order modulation (HOM), a large licence key file
will be supplied. This file can be downloaded to all the Modulators within
the system.