Operating the Equipment Locally
Page 3-6
Reference Guide: SM6610, SM6615, SM6620 and SM6625 Satellite Modulators
ST.RE.E10152.2
4. Set the port parameters as specified in Figure 3.6 and click OK.
Figure 3.6: Port Properties Dialog Box
At this point, the terminal is connected to the Modulator.
Change the Terminal Properties
From File on the Windows menu bar, choose Properties if the terminal
properties require changing. This displays the Properties dialog box.
Select the Settings tab to display the dialog box shown in Figure 3.7.
Figure 3.7: SM6600 Terminal Properties Dialog Box
If the ASCII settings require changing, click the ASCII Setup button on
the SM6600 Terminal Properties dialog box. This displays the dialog
box shown in Figure 3.8.
Required settings:
Bits per second = 19200
Data bits
= 8
Parity =
None
Stop bits
= 1
Flow control
= None
The heading varies
according to the
COM port selected.
Required settings:
Emulation = VT100 or Auto detect
Set all others as required.
Refer to Figure 3.8 for the ASCII
Setup dialog box.