Front Panel Control
Reference Guide: SM6610, SM6615, SM6620 and SM6625 Satellite Modulators
Page 4-5
ST.RE.E10152.2
4.2.2
Monitor Only Mode
All configuration and log information can be viewed but the user cannot
edit or clear logs, and cannot save or load configurations. In Monitor Only
mode the Main Menu is as follows:
Scroll down to access the remainder of the top-level options as shown in
Figure 4.3: Monitor Only Menus
Table 4.3: Monitor Only Menu Options
Top Level
Sub-level
Description
View Status
Displays the current status and temperature, and current date and
time.
View Active Alarms
Gives a snapshot of present alarms when Enter is pressed.
Logs Menu
View Alarm Log
History of alarms, e.g.:
Input stream errors.
View Event Log
History of events, e.g.:
When Modulator was restarted,
When new configuration was saved.
View Temperature Log
History of temperatures, e.g.:
Minimum, maximum, current.
View Configuration
View Parameter
Allows viewing of the current parameters individually.
View Configuration
Allows viewing of the configuration settings for configurations 0 – 9.
Æ
View Status
Main
È
View Active Alarms
Menu
↓
Logs Menu
↓
View Configuration
↓
System Menu
→
View Status
| Main
↓
View Active Alarms
| Menu
FRONT PANEL
MENUS
- Monitor Only -
Table 4.3
•
View Alarm Log
•
View Event Log
•
View Temperature Log
•
View Parameter
•
View Configuration
•
Network Settings
•
Network Time Server
•
Serial Port Settings
•
Front Panel
•
Build Information