SM6630 and SM6635 Satellite Modulators
14
2.7 Getting
Started
The following procedure is a guide to get the equipment up and running.
!"
Switch on the Modulator.
With the Modulator correctly installed and connected to the input and output
equipment, switch on the unit in accordance with the instructions given in
Section 2.6
. Confirm that it powers up correctly. If it does not, refer to
Section 4, Preventive Maintenance and Fault-finding.
!"
Establish local or remote control.
Connect the relevant terminal to the RS-232/485 port or the Ethernet port
(1 or 2). Ensure the terminal is switched on and operational. (See the
Reference Guide
for details.)
Section 3
of this Guide gives details of using the Front Panel for day-to-day
operation.
NOTE
The rear panel RS-232/485 connector is compatible with either
RS-232 or RS-485, depending upon the mode selected on the
Modulator.
!"
Select configuration parameters.
Set the required configuration parameters.
!"
Implement the configuration.
Ensure the required configuration parameters are sent from the terminal to
the Modulator and that they are implemented.