VISION 5000 Videoconferencing System
77
Ethernet
How is it done
Connect your system to a local area network. The network cable should be connected from the LAN-port at
the rear of the codec to a port in your network using a standard RJ-45 cable.
Configure your codec by performing the following:
Press MENU, select
Terminal Settings
,
TCP/IP Settings
Specify IP-assignment
DHCP
or
Static
. If
DHCP
is selected no other settings are needed. If Static is
selected,
IP-address
,
IP-subnet mask
and
Gateway
must be specified.
Example:
IP-assignment:
Static
IP-address:
192.9.200.111
IP-subnet mask:
255.255.255.0
Gateway:
192.9.200.21
See chapter
TCP/IP Settings
in
Advanced use
for further information on these settings.
Start your Web-browser. In the address field type the IP-address of the codec
Example:
192.9.200.129
You will now see the front page of the codecs Web-interface.
The following Web-browsers have been tested:
Netscape Communicator 4.05
Microsoft Internet Explorer 4.0 and 3.0
Opera 3.51