background image

Minimum

rate screw

7.     With a 7/16” wrench loosen the pilot head 

on the pilot assembly by a half-turn 

 

(Fig. #19)

8.   Slide the pilot adjustment band over and 

ensure that the hole in the orifice band is 

showing. (Fig. #20 shows NG position, 

 

Fig. # 21 shows LP position)

9.    Remove the minimum rate screw located 

in the valve. 

 

(Fig. #22)

Fig. #21

Fig. # 22

Fig. # 19

Fig. # 20

7

TC36.NG05.C 290409-12

Minimum 
rate screw

Summary of Contents for TC36.NG05.C

Page 1: ...uctions are supplementary to the Installation and Operating Instructions supplied with the fireplace and should be kept together Refer to the Installation and Operating Instructions for proper gas sup...

Page 2: ...Contents of Package 2 TC36 ng05 C 290409 12 BURNER ASSEMBLY including pilot and manifold LOG GRATE TC36 HEARTWOOD LOGS EMBER MATERIAL HARDWARE PACKAGE AIR DEFLECTOR COAL CHUNKS VERMICULITE...

Page 3: ...r leads to the electrical bulk head Fig 2 Thesparkelectrodeconnection has a red dot above it 3 Attach the pilot and gas supply tubes to the bulk head fitting and tighten Fig 3 Ensure the connections a...

Page 4: ...ly be used around the burner pan to cover up the gas lines and brackets 1 Pull apart the material into ember size pieces approximately 1 squares and gently place them into the burner pan Do not compre...

Page 5: ...ave holes and or pins Engage each pin in the corresponding holes The remaining two logs do not have holes or pins They rest in position Locate as per the diagrams fig 7 15 Note Improper placement of l...

Page 6: ...loss of life The qualified service agency is responsible for the proper installation of this kit The installation is not proper and complete un til the operation of the converted appliance is checked...

Page 7: ...by a half turn Fig 19 8 Slide the pilot adjustment band over and ensure that the hole in the orifice band is showing Fig 20 shows NG position Fig 21 shows LP position 9 Removetheminimumratescrewlocate...

Page 8: ...Fig 24 12 Press down on the center post and rotate 90 The center post should stay down Fig 25 Replace the rubber cap 13 Fill in the date and the name of the person who performed the conversion in the...

Page 9: ...e the plug Thread sealant will be required to ensure a gas tight connection Correct gas pressure requirement Supply Pressure Natural Gas Propane For purpose of input adjustment Minimum 5 0 WC 12 5 WC...

Page 10: ...tter may also be opened to enhance the Ember Material glow and lessen the flame height Caution Burner area may be hot Turn off the fireplace and allow the unit to cool before proceeding Caution Proper...

Page 11: ...LOG a 2b LEFT CENTER LOG b 2c LEFT FRONT LOG c 2d LOG WITH HOLE d 2e RIGHT CENTER LOG e 2f FRONT RIGHT LOG f 2g RIGHT BASE LOG g 2h CENTER TWIG h 2i CENTER BASE CHUNK i KIT CONTENTS 3 ORIFICE NATURAL...

Page 12: ...TECHNICAL SUPPORT 1 888 715 2664 www townandcountryfireplaces net 2975 Allenby Rd Duncan BC V9L 6V8 Printed in Canada...