082406-40
TC36.CSTE 19
ROOF TERMINATION VENTING CHART
Fig. # 40
Minimum
1' Length
of Pipe
NOTE: The vent must not exceed a total length of 65 feet.
Any combination of rise and run may be used but must be
constrained to the boundaries of this chart. A total of 4 90°
elbows or combination of other elbows equalling 90° can be
used without reducing horizontal run. For each additional 90°
elbow, or an equal combination of elbows, reduce horizontal
vent run by 2 feet. Ensure vent pipe is properly supported.
A
Minimum rise
B
Pipe length
C
Maximum run
D
Pipe length
Maximum
61”
1-12”
41"
1-24"
67"
1-18"
75 1/4"
1-48" 1-12"
73"
1-24"
9' 3 1/4"
2-48"
77 1/4”
1-12" 1-18”
13' 2 1/2"
3-48"
83 1/4”
1-24" 1-12”
16' 11 3/4"
4-48"
89 1/4”
1-24" 1-18”
18' 10"
4-48" 1-24"
97”
1-48”
20' 10”
5-48"
For other rise/run combinations see chart below
**
**
All dimensions are approximate. Both rise and run may vary with differ-
ent combinations of pipe.