page
8
TC42_B2
230905-36
CONTROL BOX
The gas control system is housed in a control box remote of
the fi replace. Flexible conduits attach the control box to the
fi replace and house all the plumbing and wiring to the burner.
This unique design allows the control box to be mounted in
a variety of positions on the right or left side of the fi replace.
The box can be framed into the front right or left face or the
right or left sidewall of the fi replace enclosure.
The control box assembly is shipped strapped to the side of
the fi replace and needs to be attached to the unit.
If installing on the left hand side, the casing and fi rebox inlet
covers must be removed and reinstalled on the opposite side
of the unit.
DEFAULT I
N
STALLATIO
N
1) Insert the inlet box into the opening at the base of the right
hand side of the unit, as shown in Fig # 11, taking care not to
damage pilot, plumbing or wires.
2) Install 4 screws from the inside of the fi rebox to secure the
inlet box to the fi rebox.
CO
N
TROL BOX FRAMI
N
G
Caution: When positioning the control box, do not over
bend the conduit or use excessive force, as damage may
occur.
1) Remove window frame latch tool and set aside.
2) Remove 4 screws holding control panel in place and
carefully lift off over the control knobs, being sure not to
damage wires and connections to the "Pilot Flame" indi-
Fig. # 11
INSERT CONTROL ASSEMBLY
INLET BOX
INSTALL SCREWS TO SECURE INLET BOX
Fig. # 10
PILOT
FLAME IN-
DICATOR
CONTROL
DOOR AND
FRAME
GAS
VALVE
BURNER
SWITCH
CONDUIT
BATTERY SPARK
IGNITER
MANUAL MILLIVOLT VALVE
cator (millivolt control system only). Carefully disconnect
wires from indicator, and set aside.
3) Remove screws attaching the control box door and its
inner frame, and place aside.
4) Attach control box to framing at predetermined depth,
allowing room for wall fi nishing material. Side brackets
can be adjusted for a trim fi t.
5) Replace door/inner frame assembly and fasten in place.
Note: Gas supply plumbing must be completed and the
spark igniter battery or backup batteries installed before
reinstalling the front control panel.
6. Reconnect "Pilot Flame" indicator wiring and reinstall
control panel.