background image

TCWS.54NG04.C 180208-12

10  Place the front pebble cluster over 
the burner. Use the pins on the burner 
and holes in the pebble cluster to locate 
the pebbles on the burner. (Fig. #10)

11  Place the top rocks on top of the 
pebble clusters as shown. Use the slots 
in the top rock to align to the tabs on the 
pebble clusters. (Fig. #11 & below)

12  Repeat the sequence of placing 
the front, rear and top rocks three more 
times until the burner is covered.

13  Place equalizer rocks either end 
of burner as shown. (Fig. #12)

14  Install front porcelain cover (wide 
edge should face the front). (Fig. #13 
& #13A)

REAR CLUSTER

FRONT CLUSTER

SLOPE INTO
THE CLUSTER

WIDE SECTION
TO FRONT

WIDE EDGE TO FRONT OF 
FIREPLACE

Fig #10

Fig #11

Fig #12

Fig #13

Fig #13A

5

Summary of Contents for TCWS.54NG04.C

Page 1: ...E HOMEOWNER These instructions are supplementary to the Installation and Operating Instructions supplied with the fireplace and should be kept together Refer to the Installation and Operating Instruct...

Page 2: ...manual prior to burner installation Page 23 1 Attachfuelflexlineandpilotassembly tobulkhead fittings Fig 1 1 BURNER TRAY ASSEMBLY Fig 1 2 3 4 LBS SAND 4 PEBBLE ASSEMBLIES Includes front and rear pebbl...

Page 3: ...ectrical bulk head fitting Fig 2 3 Tilt burner tray length wise and insert into the firebox Fig 3 4 While supporting one end of the burner tray connect gas line to the tee on the un derside of the bur...

Page 4: ...uri tube over the orifice Test for connection by lifting at a location pin on the right side of the burner Repeat with left burner Fig 7 CAUTION The burners should be tightly butted up against each ot...

Page 5: ...rock to align to the tabs on the pebble clusters Fig 11 below 12 Repeat the sequence of placing the front rear and top rocks three more times until the burner is covered 13 Place equalizer rocks eith...

Page 6: ...the components supplied with this burner CAUTION The gas supply and electrical power shall be shut off before proceeding with the conversion Note Factory supplied components must be used to ensure co...

Page 7: ...The minimum rate screw is sealed with an O ring Use a thin bladed screwdriver to back the screw out past the limit of the threading At this point a groove on the screw body will be visible just above...

Page 8: ...protective backing and apply the conversion label directly overthegasspecificationsontherating label 13 Re locate the control box shield and re attach the access panel to the side of the firebox with...

Page 9: ...ant will be required to ensure a gas tight connection Note To test the gas pressure turn off the gas supply before removing the plug from the supply pressure test port or manifold pressure test port V...

Page 10: ...flame ap pearance after the fireplace has reached operating temperature See Fig 26 for proper flame pattern Open primary air if the window glass and firebox have carbon accumulation and or the flames...

Page 11: ...MAIN SUPPLY TUBE 5019 223 4 PILOT TUBE 5019 229 ITEM DESCRIPTION PART NO 5 PILOT ASSEMBLY CONVERTIBLE 5005 025 6 ORIFICE NATURAL GAS 32 5021 332 A 7 PROPANE CONVERSION KIT TC36 LPCSTE01 8 SAND TC42 S...

Page 12: ...Printed in Canada Technical support 1 877 715 2664 Web site www townandcountryfireplaces net 2975 Allenby Rd Duncan BC V9L 6V8...

Reviews: