background image

0RODUCT3PECIlCATIONS

242

-EASUREMENT#HANNELS

4EMPAND(UMIDITY#HANNEL

-EASUREMENT)TEM

4EMPERATUREAND(UMIDITY

%XTERNAL4EMP(UMIDITY
3ENSOR

TO

Ɏ

TO

ɋ

&

)

Ȇ

TO2(

-EASUREMENT$ISPLAY
2ESOLUTION

Ɏ

Ȫ

ɋ

&

ȫȆ

2(

-EASUREMENT!CCURACY

!VG

Ⱦ

Ɏ

Ȫ

Ⱦ

ɋ

&

ȫ

Ⱦ

2([AT

Ɏ

ɋ

&

)

AND2(]

2ECORDING)NTERVAL

SECONDS

MINUTES

4OTALOFCHOICES

2ECORDING#APACITY

READINGS

ȿ

#HANNEL

2ECORDING-ODE

%NDLESS

/VERWRITEOLDESTDATAWHENCAPACITYISFULL 

Ȇ

/NETIME

3TOPREADINGWHENCAPACITYISFULL

,#$$ISPLAY)TEMS

#URRENT2EADINGS

Ȇ

2ECORDING3ETTINGS

Ȇ

"ATTERY,IFE7ARNING

Ȇ

/VER-EASUREMENT2ANGE7ARNING

Ȇ

5NIT

0OWER

,ITHIUM"ATTERY,33!&4  

"ATTERY,IFE

!PPROXMONTHS!PPROXYEARSWITH242"

"ATTERYLIFEDEPENDINGONMEASUREMENTENVIRONMENTRECORDING

INTERVALANDBATTERYPERFORMANCE 

7IRELESS-ETHOD

&##0ART3ECTION

4RANSMISSION$ISTANCE

5PTOFT;METERS=-AYVARYWITHCONDITIONS 

)NTERFACE

7IRELESS#OMMUNICATION242# 

Ȇ

/PTICAL#OMMUNICATION

242#42#42# 

#OMMUNICATION3PEED

7HENDOWNLOADINGDATA7IRELESS !PPROXREADINGS

PERMINUTE;#OLLECTIONOFAFULLUNITOFDATA!PPROX

SECONDSOPTICALCOMMUNICATION!PPROXSECONDS =

7ATER2ESISTANCE

)0RATEDFORUSEINDAILYLIFE

ɦ

$IMENSIONS

(X7X$MMEXCLUDINGPROTRUSIONSANTENNALENGTH

MM WITH,ARGE#APACITY"ATTERY0ACK$MM

7EIGHT

!PPROXOZINCLUDINGLITHIUMBATTERY WITH,ARGE

#APACITY"ATTERY0ACK!PPROXOZ

5NIT4EMP2ESISTANCE

Ƚ

ɋ

&

TO

ɋ

&

ɦ

3TANDARD3ENSOR)NPUT#ABLE

42

LENGTH!PPROXM 

ȿ

!CCESSORIES)NCLUDED

,ITHIUM"ATTERY,33!&4  

ȿ

Ȇ

4UBE

ȿ

3TRAP

ȿ

Ȇ

5SERgS-ANUAL7ARRANTY 

ȿ

ɦ

.OTE4HE7ATERRESISTANCERATINGWITHTHESENSORORINPUTCABLECONNECTEDIS)0NOTFOR

CONTINUEDIMMERSION

ɦ

2ADIOCOMMNICATIONCANNOTBEOPERATEDATBELOW

ɋ

&

DEGREESORLESS

5SERgS-ANUAL

4HANKYOUFORPURCHASINGTHISPRODUCT#AREFULLY
READANDFULLYUNDERSTANDTHESEINSTRUCTIONSBEFORE
USINGTHISUNIT

7IRELESS4EMPERATURE$ATA,OGGER

       

ɜ

Please read this manual carefully before using the product.

ɜ

All rights of this User’s Manual belong to T&D Corporation. It is prohibited to use, 

duplicate and/or arrange a part or whole of this User’s Manual without the 
permission of T&D Corporation.

ɜ

Please follow the safety precautions carefully.  We cannot guarantee nor are we 

responsible for safety if this product is used in any manner other than was 
intended.

ɜ

T&D Corporation accepts no responsibility for any malfunction of and/or trouble 

with this product or with your computer that is caused by the improper handling of 
this product and will deem such trouble or malfunction as falling outside the 
conditions for free repair of the attached warranty.

ɜ

T&D Corporation accepts no responsibility for any result or effects from using this 

User’s Manual. 

ɜ

Figures and illustrations in this manual may be slightly simplified and may differ 

from the actual product.

ɜ

On screen messages, figures or illustrations in this manual may vary slightly  or 

be simplified from the actual messages and product.

ɜ

We sincerely hope that the contents of this manual are true and complete. If you 

find any information to have been omitted, or if the information within is confusing 
or mistaken please, contact your retailer or T&D Corporation.

ɜ

Microsoft

®

, Windows

®

 and WindowsNT

®

 are registered trademarks of Microsoft 

Corporation USA and are binding in the USA and all other countries. Company 
names and product names are trademarks or registered trademarks of each 
company.

ɜ

This User’s Manual cannot be reissued, so please keep it in a safe place. 

ɜ

Please carefully read this User’s Manual and Warranty.

ɟ

Notices about this User’s Manual

ɟ

Safety Precautions and Instructions

ɦ

Please carefully observe the following safety measures when using our 
product.

To prevent any loss or damage to our customers, other people and/or property, and to ensure the proper use of our products we ask that before using 
our product you carefully read, understand and follow the safety rules and precautions for our products as outlined below.

Ⱥ

Explanation of Warning Symbols

Ȼ

DANGER

These entries are actions that absolutely under no 
circumstance should be taken. The taking of such an action 
may cause serious personal physical damage or death.

CAUTION

These entries are actions that if taken may lead to physical 
injury or damage to persons or things.

Ⱥ

Explanation of Picture Symbols

Ȼ

This symbol denotes an important warning or caution. Inside or near the 
symbol will appear another symbol giving details. 
(EX:

stands for ELECTROCUTION)

This symbol denotes a forbidden action. Inside or near the symbol will 
appear another symbol giving details. 
(EX:

stands for DO NOT TAKE APART)

This symbol denotes an action that you must take. Inside or near the 
symbol will appear another symbol giving details.
 (EX:

stands for TAKE PLUG OUT OF SOCKET)

DANGER

The RTR-53 is a devices to measure temperature humidity. Do not 
use this unit for any purpose other than temperature humidity 
measurement.

If any smoke or strange smells are emitted from the unit, immediately 
cease using it.

Continued use may cause fire, electrocution or damage.

If water or a foreign object enters the case, immediately cease using 
it.

Please be careful when using in overly hot or cold environments, 
touching the units may cause burns or frostbite.

Store all batteries, sensors and Thermo Recorder units out of the 
reach of children.  It is dangerous to swallow batteries.

Do not take apart, repair or modify the main unit. 

It may cause fire, electrocution or damage. Ask the shop where you 
purchased the products or T&D Corporation to carry out any repairs.

Do not use any batteries other than those that are recommended. It 
may cause fire or damage.

CAUTION

Customer's name:
Address:
Phone No.:

Dealer's name:
Address:
Phone No.:

Guarantee period

12 months from date of purchase

Date of purchase

Provisions for Free Repair

1. If the unit does not work properly despite the fact that the customer used it 

properly and in line with the User's Manual, the unit shall be repaired free 
of charge through the distributor from which the unit was purchased.

2. If the customer requests free repair because of trouble within the warranty 

period, bring or send the unit along with the warranty to the dealer.  A 
service charge may be added if a repairperson must be sent out to the 
place of use for repair.

3. If you have moved after purchasing, or the product was received as a gift, 

or there are some difficulties contacting the shop from which you purchased 
the unit, please contact us directly for service. 

4. Free repair is not available in the following cases even though it is within 

the warranty period:

1. Trouble or damage was caused by careless operation, natural disaster, 

fire, public pollution, or use of a power source other than specified.

2. If repair, adjustment, disassembly or modification of the unit has been 

carried out by a person other than a T&D authorized engineer.

3.Trouble or damage was caused by transportation, movement or dropping 

of the unit after purchase.

4.Failure to submit the Warranty or failure to fill in all items required in the 

Warranty.

5. The Warranty cannot be reissued. 

This Warranty only promises customers free repair within the period and 
conditions clarified in this Warranty. Therefore, the customer's legal rights 
will not be limited by this Warranty. For further information on repair and 
other service questions after the termination of the warranty period, contact 
your dealer.

This is printed on 100% recycled paper.

Warranty

Wireless Regulations

Do not drop or expose the unit to strong impact.

Do not use or store the unit in places such as listed below: 
It may cause electrocution, fire or damage to the unit or to your  
computer.

ɜ

Areas exposed to direct sunlight

ɜ

Areas exposed to water or high-pressure water flow.

ɜ

Areas exposed to organic solvents and corrosive gas.

ɜ

Areas exposed to strong magnetic fields

ɜ

Areas exposed to static electricity.

ɜ

Areas exposed to fire or overheating.

ɜ

Areas exposed to excessive dust or smoke.

This product has been designed for private or industrial use only. 
It is not for use in situations where strict safety precautions are 
necessary such as in connection with medical equipment whether 
directly or indirectly.

We are not responsible for any malfunction or trouble caused by the 
use of our product or by any problem caused by the malfunction of 
our unit.  Please be fully aware of this before using our product.

Battery life depends on the measurement environment, 
communication frequency, recording interval and battery quality.

Battery terminals may provide insufficient contact due to age or 
vibration. Please be careful not to lose data due to insufficient 
contact.

Pay attention to water leakage or foreign objects entering into the 
unit case as in the following cases.

ɜ

The case was closed with dust, hair, etc., on the rubber packing or in the 
groove for the packing. 

ɜ

The rubber packing becomes damaged. (In this case, please purchase 
the optional maintenance set.)

ɜ

The unit suffered from significant temperature change while wet.  
Especially if the temperature change is from high to low.

Remove batteries from any unit that is not to be used for a long period 
of time. 

Batteries left in a unit not being used for a long time may leak and cause a 
malfunction.

About the TR-3310, the standard temperature and humidity sensor for 
RTR-53.

ɜ

Use the sensor only within the measurable temperature and humidity 
range (Temperature: 32.0 to 131.0

ɋ

&

, Humidity: 10 to 95

ɓ

RH)

ɜ

The Temperature/Humidity sensor cable cannot be extended.

ɜ

When the sensor is not used, put it in the attached plastic bag with a 
drying agent and keep it in cool, dark place at 41 to 77

ɋ

&

and 30

ɓ

RH 

or less.

ɜ

The replacement period for the standard sensor is 1 year. Replace it 
when 1 year has passed after opening the bag.

Do not put your fingers or foreign matter into the sensor connection.

/PERATETHEUNITSWITHTHELATESTVERSIONOF;4$2ECORDERFOR
7INDOWS 24253  =

4HELATESTVERSIONSOFTWARECANBEDOWNLOADEDFROMOURHOMEPAGE

2ADIO%-#AND3AFETY2EGULATIONS

4HISDEVICECOMPLIESWITHPARTOFTHE&EDERAL#OMMUNICATIONS
#OMMISSION&## RULESANDWITH233OFTHE)NDUSTRY#ANADA)#
/PERATIONISSUBJECTTOTHEFOLLOWINGCONDITIONS
 4HISDEVICEMAYNOTCAUSEHARMFULINTERFERENCEAND
 4HISDEVICEMUSTACCEPTANYINTERFERENCERECEIVED
INCLUDINGINTERFERENCETHATMAYCAUSEUNDESIREDOPERATION

)NQUIRIES

4$#/20/2!4)/.

3ASAGA-ATSUMOTO#ITY.!'!./*!0!.
4EL&AX
%MAILOVERSEAS TANDDCOJP
(OMEPAGEHTTPWWWTANDDCOM

.OTE4HIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR
A #LASS " $IGITAL $EVICE PURSUANT TO 0ART  OF THE &## 2ULES4HESE LIMITS
ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST HARMFUL INTERFERENCE IN
A RESIDENTIAL INSTALLATION4HIS EQUIPMENT GENERATES USES AND CAN RADIATE RADIO
FREQUENCYENERGYANDIFNOTINSTALLEDANDUSEDINACCORDANCEWITHTHEINSTRUCTIONS
MAYCAUSEHARMFULINTERFERENCETORADIOCOMMUNICATIONS
(OWEVER THERE IS NO GUARANTEE THAT INTERFERENCE WILL NOT OCCUR IN A PARTICULAR
INSTALLATION)FTHISEQUIPMENTDOESCAUSEHARMFULINTERFERENCETORADIOORTELEVISION
RECEPTIONWHICHCANBEDETERMINEDBYTURNINGTHEEQUIPMENTOFFANDONTHEUSER
IS ENCOURAGED TO TRY TO CORRECT THE INTERFERENCE BY ONE OR MORE OF THE FOLLOWING
MEASURES

2EORIENTORRELOCATETHERECEIVINGANTENNA
)NCREASETHESEPARATIONBETWEENTHEEQUIPMENTANDRECEIVER
#ONNECTTHEEQUIPMENTINTOANOUTLETONACIRCUITDIFFERENTFROMTHATTOWHICH

THERECEIVERISCONNECTED

#ONSULTTHEDEALERORANEXPERIENCEDRADIO46TECHNICIANFORHELP

Global Sensors
P.O. Box 369
Mount Holly, NC 28120
(704) 827-4331
(866) 402-8282
(704) 827-4883 (FAX)

info@global-sensors.com
www.global-sensors.com

Reviews: