background image

To start and stop recording, make or change the various recording settings and/or collect data please see the following instructions.
For details about communication please see the User's Manual that comes with the RTR-57U . You can also find detailed 
information in the User's Manual that accompanies the software and in the Help Menu of the software.

Using Wireless Communication with an RTR-57U Unit 

By registering an RTR-53A unit as a Remote Unit of an RTR-57U, it is possible to carry out wireless data communication (special 
short wave radio) allowing you to start and stop recording, make recording condition settings and collect data without having to 
handle the RTR-53A units.

If you are going to be using wireless communication it is 

necessary to register the [Group Name] and [Remote Unit 
Name] information in the RTR-57U units.

The wireless communication range, if unobstructed and 

direct, is about 

100 meters

. In some cases communication 

cannot take place even within 

100 meters

. Please check 

first by carrying out the wireless communication test with 
the remote units.

3. Settings and Communication

1. Wireless Thermo Recorder RTR-53A

Outline of System

This system makes ave of the RTR-53A unit to measure and record temperature and humidity 
data, which can then be downloaded via wireless transmission to our handheld RTR-57U Data 
Collector Unit. The RTR-57U Unit can then be connected to your computer for data analysis 
and management with our exclusive software.

Besides the collection of recorded data, it is possible to monitor current temperature and 
humidity readings, start recording and check data anytime without physically collecting the 
RTR-53A units. Communication between units can be done via optical communication, as well 
as wireless communication.

Optical Communication with an RTR-57U 

By simply placing an RTR-53A unit face down on an RTR-57U you can carry out recording start settings and changes, as well 
as, collect recorded data via optical communication.

2. Getting Started

1.Remove the screws and take off the back case.

3. Check the rubber packing for any cuts or scratches and replace the cover as it was when 

opened.

Make sure no water or foreign objects get inside the case.

If dirt or scratches are present on the rubber packing, water resistance 

will be reduced.

Be sure to fasten the cover tightly.

2. Insert the battery in its tube and place it in the unit as shown in the diagram.

Make sure that + and - are correct.

Use in cold environments may cause difficulty in reading the display; this is not a malfunction.

Recording Status (REC) 

LIT UP: displayed during recording or when FULL of 
data. 
BLINKING: displayed when waiting for a 
programmed recording to start

Low Battery Life Warning Indicator (BAT): displayed 

when time to change the battery.

Measurement Reading and Message Display

Unit of Measurement: displays unit of measurement

LCD Display

Insert the batteries

Basic Functions of RTR-53A

Wireless Communication Function

Via special short wave radio communication recorded data can be 

 an 

RTR-53A unit and saved to the RTR-57U Data Collector Unit. Recording settings and 
recording start can also be controlled via wireless communication.
Note: In order to collect data via wireless communication, it is necessary to register via 

computer the RTR-53A unit as a Remote Unit in the RTR-57U Unit you wish to use.  
For details about making these settings, please see the Help Menu in the software 

          or the User's Manual for the software.

Humidity Measurement Range: 10

95%RH

With the included sensor, the RTR-53A can simultaneously measure temperature (0

55

) and humidity (10

95

RH).

Our newly designed sensor for RTR-53A can withstand a certain amount of condensation. 
Note: The main unit is designed for use in environments with an ambient temperature 

between -40

80

 and is water resistant. The sensor is designed for use in areas 

with a temperature between 0

55

 and should not be used areas that are wet or 

are prone to condensation.

Communication with your Computer

By placing an RTR-53A unit face down on an RTR-57U unit that is connected to your computer, you can make any necessary 
recording conditions settings and changes, start recording and download recorded data easily via your computer display. 

CHECK

This is displayed under the following conditions: after purchasing and putting in the 
batteries for the first time, if the battery ter/- were mistaken and a short 
occurred, or if the batteries are replaced after having been taken out for a long period. 
If this is displayed, all data that had been stored in the main unit has been erased.

Full Memory

If recording under the ONE-TIME MODE, when the data readings reach the upper 
limit of 8,000 readings, recording will stop and this will be displayed intermittently with 
the current temperature.

Wireless Transmission

This will be displayed when transmitting data to an RTR-57U unit via wireless 
communication.

No Sensor Connected

Displayed when a sensor has not been connected, disconnected or the wire has been 
broken. Measurement and recording will continue and battery power consumed.

Part Names

Antenna

LCD

Optical Communication 
Port

Temperature and 
Humidity Sensor

Place the RTR-53A 
unit face down on 
the RTR-57U

4. Connect the Temperature and Humidity Sensor.

    

Make sure that the sensor is properly connected by 

inserting it until you hear a clicking sound.

Measurement range is 0~55

 (Temperature) and 

10~95%RH (Humidity)

5. After Inserting the Batteries

If necessary make changes to the default recording settings according to your usage and needs. If you are going to 
be using wireless communication it is necessary to register the [Group Name] and [Remote Unit Name] information 
at this time. See [3. Settings and Communication]

Note:

When changing batteries make sure to carefully read [5.Changing Batteries].

If nothing appears on the LCD Display, please follow the above instructions again.

Upon first installation of the batteries, measuring and recording will automatically begin at the factory set default 

recording settings: (Recording Interval: 1 minutes / Endless Mode / Immediate Start)

After replacing the batteries the settings will return to the most recent recording settings.

4. If you do not change the battery even under conditions in 3 above, the display will go blank. 

All of the recorded data will be erased. If at this time a new battery is placed in the unit, [CHEC] will appear on the display after 

which recording will begin again using the previously set recording conditions.

5. Changing the Battery

Note:

Once the battery indicator [BAT] appears, replace the old battery with a new one as soon as possible.

After removing the old battery, all recorded data will be lost if a new battery is not inserted within 1 minute. Make sure to complete 

the battery change within 1 minute.

If the battery direction is incorrect (+/-) and a short occurs, all recorded data saved in the main unit will be lost.

2. 

If you do not change the battery and continue using the unit, the measurement display will intermittently display 

[bAtt]. Please change the battery at once. 

If at this time a new battery is placed in the unit, recording will continue and downloading of saved data can be done.

 

Recording:  OK

Wireless Communication :  NO
 

Data Download:  NO

1. When battery power becomes low, the battery indicator (BAT) will appear in the LCD display.

If you change the battery at this time, recording will continue uninterrupted and the downloading of recorded data is possible. 

 

Recording:  OK

Wireless Communication :  OK
 

Data Download:  OK

If you do not change

3.

If you do not change the battery even under conditions in 2 above, the REC indicator will disappear and 

measurement display area will display [SLP].

Recording will stop and recorded data until this point will be saved

If at this time a new battery is placed in the unit, downloading of saved data can be done. To start recording again please set the 

recording conditions via your computer or RTR-57U and begin recording. See {1. Outline of System}

If you wish to start recording using the previous recording settings, see the user's manual for RTR-57U or the TR-50C or the 

software (Thermo Recorder for Windows) and in the Help Menu of the software.

 

Recording:  

NO

Wireless Communication :  NO
 

Data Download:  NO

Data Capacity: 8000 Readings x 2 Channels

Can record up to 8000 temperature and 8000 humidity readings for a total of 16,000 readings. 
ONE-TIME MODE: When the data capacity of 8,000 readings is reached, the LCD display will 
indicate [FULL] and recording will stop. 
ENDLESS MODE: When the data capacity of 8,000 readings is reached, the data will be erased 
in order from the oldest data first and recording will continue. 

*Below is an estimate of the amount of time it will take for the unit to become [FULL] in the ONE 

TIME MODE. 

Calculation Example: 
30 sec (recording interval) x 16,000 readings (capacity limit) = 480,000 seconds 
 

 

= about 5 days and 13 hours. 

Recording Interval

1 second

30 seconds

15 minutes

60 minutes

Time period

4 hours 26 min.

5 days 13 hours

166 days 16 hours

1 year 10 months

Recording Condition Settings

Settings such as Recording Mode, Recording Interval, Programmed Start, Immediate Start, and 
Unit of Display can be easily made via computer or an RTR-57U.

Recording Start / Stop

Recording can be started / stopped via computer and started via RTR-57U. 
Note: By starting a new recording session, all previously recorded data will be erased form the 

main unit. If you wish to save the data, make sure to download it to an RTR-57U unit or to 
your computer before beginning a new recording session.

Downloading Recorded Data (Data Collection)

Data downloaded to your computer can be processed into graphs, lists, saved to files, changed 
to text file, and printed out.

Upper and Lower Limit Settings for Temperature and Humidity

By setting upper and lower limits, a check will occur for data exceeding those limits each time 
data is downloaded to an RTR-57U unit.

Insert cable into jack

4. Part Names and Functions 

If you do not change

If you do not change

Place the RTR-53A unit face 
down on the RTR-57U

100m

Group

Please note that this User's Manual has been written based on the presupposition that an RTR-57U Data Collector unit is used as a Base Unit.
When using an RTR-50 or an RTR-5W unit as a Base Unit, see also the User s Manual that comes with the Base Unit being used. 

Downloaded from 

 

 

Summary of Contents for RTR-53A

Page 1: ...User s Manual Thank you for purchasing this product Carefully read and fully understand these instructions before using this unit Wireless Temperature Data Logger ...

Page 2: ... object enters the case immediately cease using it Please be careful when using in overly hot or cold environments touching the units may cause burns or frostbite Store all batteries sensors and Thermo Recorder units out of the reach of children It is dangerous to swallow batteries Do not take apart repair or modify the main unit It may cause fire electrocution or damage Ask the shop where you pur...

Page 3: ...on Data Capacity 8000 Readings x 2 Channels Can record up to 8000 temperature and 8000 humidity readings for a total of 16 000 readings ONE TIME MODE When the data capacity of 8 000 readings is reached the LCD display will indicate FULL and recording will stop ENDLESS MODE When the data capacity of 8 000 readings is reached the data will be erased in order from the oldest data first and recording ...

Page 4: ...surement range is 0 55 Temperature and 10 95 RH Humidity 5 After Inserting the Batteries If necessary make changes to the default recording settings according to your usage and needs If you are going to be using wireless communication it is necessary to register the Group Name and Remote Unit Name information at this time See 3 Settings and Communication Note When changing batteries make sure to c...

Page 5: ...ssary to register the Group Name and Remote Unit Name information in the RTR 57U units The wireless communication range if unobstructed and direct is about 100 meters In some cases communication cannot take place even within 100 meters Please check first by carrying out the wireless communication test with the remote units 3 Settings and Communication Optical Communication with an RTR 57U By simpl...

Page 6: ...nd a short occurred or if the batteries are replaced after having been taken out for a long period If this is displayed all data that had been stored in the main unit has been erased Full Memory If recording under the ONE TIME MODE when the data readings reach the upper limit of 8 000 readings recording will stop and this will be displayed intermittently with the current temperature Wireless Trans...

Page 7: ...ntinue and downloading of saved data can be done Recording OK Wireless Communication NO Data Download NO 1 When battery power becomes low the battery indicator BAT will appear in the LCD display If you change the battery at this time recording will continue uninterrupted and the downloading of recorded data is possible Recording OK Wireless Communication OK Data Download OK If you do not change 3 ...

Page 8: ...o EMC and Safety Regulations RTR 5 Series complies with technical specifications required under EN 301 489 3 with battery and AC Adaptor EN 300 220 3 and EN 60950 2000 Allowed to use in A B D DK F I P S SW UK N NL CH FIN AUS NZ ...

Page 9: ...ronment recording interval and battery performance Wireless Method ETSI EN 300 220 Transmission Distance Up to 100 meters May vary with conditions Interface Wireless Communication Optical Communication Communication Speed When downloading data Wireless Approx 2 000 readings per minute Collection of a full unit of data Approx 420 seconds optical communication Approx 160 seconds Water Resistance IP6...

Page 10: ...ht T D Corporation All rights reserved 2011 08 16504350001 5th Edition Shimadachi 817 1 Matsumoto Nagano 390 0852 Japan Tel 81 263 40 0131 Fax 81 263 40 3152 E mail support tandd com Homepage http www tandd com ...

Reviews: