25
26
Wireless Communication
Wireless communication can only be carried out with RTR-
51
/
52
/
53
and RVR-
52
A units that have been registered as Remote Units via the
provided software
『
T&D Recorder for Windows US
』
.
◆
Register the Data Logger Unit to be used
as a Remote Unit
1.
Check the condition of radio wave transmissions by using the
Radio Wave Monitor. (See p.
56
)
2.
Connect the cable so that communication can occur between the
data logger and your computer. (See p.
11
~)
Communication Cable
(to computer)
Place the unit face down
on the RTR-
57
U.
3.
Open
『
T&D Recorder for Windows
US
』
.
4.
In the Main Window, click [Remote Unit Registration] and carry
out the registration.
[Remote Unit Registration] Icon
If you wish to make Recording Start settings via computer, see the [Help
Menu] in the display for the type of logger you wish to make settings for.
Details can also be found in the
『
T&D Recorder for Windows US
』
User's
Manual explanation of the [Recording Start] display.
◆
Recording Condition
(Recording Mode / Recording Interval) Settings
Please extend the antenna when using wireless communication.
The following settings and changes can be made from the main unit:
●
Recording Mode
(
One Time / Endless
)
●
Recording Interval
●
Recording Start Date and Time (Immediate / Programmed Start)
Note
・
If you make recording condition changes while recording, all previously recorded data
will be lost. Please make sure to download all recorded data before making changes.
・
Changes in recording conditions will result in a lifting of the upper and lower limits that
had been set for each unit. If you wish for those settings to remain in effect, please
make sure to use the [Read Settings] function before making any changes. (See p.
29
for
details.)
①
②
1.
In the Main Menu, click [REC SETTINGS]
and then [
Wireless].
2.
Select the Remote Unit for which you
wish to make settings.
①
Select a Group in which Remote Units are
registered.
②
Select a Remote Unit or [By Group].
・
Before selecting a Remote Unit you can run a search to find all Remote Units with
which communication is possible. Those units with which communication is possible
will appear with a
「
」
mark next to them.
(See p.
47
for details)
3.
Make Recording Condition Settings.