RTR500BW Specifications

Compatible Devices

Remote Units:  RTR-602S / 602L / 602ES / 602EL, RTR-601-110 / 130 / E10 / E30

Repeaters: RTR500BC, RTR-500

Maximum Number of 

Registrations

Remote Units: 50 units

Repeaters: 10 units x 4 groups

Communication 

Interfaces

Short Range Wireless Communication

  Frequency Range: 902 to 928MHz

  RF Power: 7mW

  Transmission Range: About 50 meters (if unobstructed and direct)

Wired LAN (RJ45 connector 100 Base-TX/10 Base-T)

Wireless LAN (IEEE 802.11 a/b/g/n, WEP(64bit/128bit) / WPA-PSK(TKIP) / WPA2-PSK(AES))

Bluetooth

®

 4.2 (Bluetooth Low Energy) For Settings 

*1

USB 2.0 (Mini-B connector) For Settings

Optical Communication (proprietary protocol)

Communication Time

Data Download Time (for 16,000 readings)

Via wireless communication: About 2 minutes

An additional 30 seconds should be added for each Repeater. 

*2

External Output 

Terminal:

PhotoMOS Relay Output

OFF-State Voltage: AC/DC 50V or less

ON-State Current: 0.1 A or less

ON-State Resistance: 35Ω

Communication 

Protocol 

*3

HTTP, HTTPS, FTP, SNTP, DHCP

Power

AC Adaptor (AD-05A4)

PoE (IEEE 802.3af)

Dimensions

H 83 mm x W 102 mm x D 28 mm (excluding antenna)

Antenna Length: 115 mm

Weight

Approx. 130 g

Operating 

Environment

Temperature: -10 to 60°C

Humidity: 90%RH or less (without condensation)

*1:  

RTR-600 Series loggers do not have Bluetooth capability.

*2:  

When using RTR500BC as Repeater. Depending upon conditions it may take up to an additional 2 minutes.

*3:  

Client Function. Communication via proxy is not supported.

The specifications listed above are subject to change without notice.

Summary of Contents for RTR500BW

Page 1: ...lling the Device 5 Registering a Base Unit to T D WebStorage Service 7 Remote Unit Settings Using RTR 600 Settings Utility 8 Making Clock and Operational Settings 8 Preparing Item and User Tables for...

Page 2: ...TR500BC RTR 500 when used as a Repeater Current Readings The most recent measurements recorded by a Remote Unit Recorded Data Measurements stored in the Remote Unit Current Readings are not available...

Page 3: ...settings window does not appear automati cally The USB driver installation may not have been installed correctly Please see Help for Unit Recognition Failure and check the USB driver 4Enter the follo...

Page 4: ...es does not support this function If you use the RTR500BW with RTR 600 Series only change the Sending Current Readings setting to OFF By default the settings for Auto Transmission of Recorded Data are...

Page 5: ...ing via USB Otherwise wireless communication may not be possible due to noise 1Connect the Base Unit to the wired or wireless LAN If the target Base Unit is connected to a PC disconnect the USB cable...

Page 6: ...position the Remote Unit or add a Repeater If no antenna mark appears a communication error has occurred Try to reposition the Remote Unit or add a Repeater Please refer to section Notes and Precautio...

Page 7: ...side menu open Device Settings 3In the upper right of the screen click on Device 4Enter the serial number and registration code for the RTR500BW then click Add The serial number and registration code...

Page 8: ...the target Base Unit and select Base Unit Settings in the pop up menu Enter the password and click OK 4When the Remote Unit Settings window appears select the target Remote Unit and click Clock Setti...

Page 9: ...Item Table as an example 2Right click in the left side box and select Insert Table from the pop up menu Set the table name 3To make or edit the item list for the inserted table right click in the rig...

Page 10: ...menu 2Select Create New from the drop down list at the top of the Work Group Table window The Edit option allows you to rename or delete a Work Group Table 3In the displayed window enter a desired na...

Page 11: ...window select Operation Search Network to search for Base Units on the network 2Right click on the target Base Unit and select Base Unit Settings in the pop up menu Enter the password and click OK 3Se...

Page 12: ...k Download to open the Data Download page Download 2Click the Download button for the recorded data you wish to download If you wish to download multiple recorded data files place a check next to the...

Page 13: ...window place a check mark next to the target Remote Unit and click Start to start downloading Downloaded data will be saved as a recorded data file in the specified storage folder Recorded data store...

Page 14: ...ets of data in one table When the data table is open go to File Open and select the additional file To save these files as one file go to File Save All Data As The saved files are in puw format and ca...

Page 15: ...Time Data Download Time for 16 000 readings Via wireless communication About 2 minutes An additional 30 seconds should be added for each Repeater 2 External Output Terminal PhotoMOS Relay Output OFF S...

Reviews: