PRODUCT TEST CERTIFICATE

Product Serial Number:

Date of Manufacture:

16

FACTORY DECLARATION

This Locking Mechanism has been fully factory tested, each unit is tested in accordance with ‘clause 
15’ of the products ATEX certificate and ‘Conditions of Manufacture’ as set out in the products ATEX 
& IECEx certificates.  

When correctly installed mechanically and electrically as described, the SX EX ELECTROMAGNETIC 
LOCK will provide both a safe & reliable locking solution and door status information for access 
control purposes.

DESCRIPTION OF EQUIPMENT OR PROTECTIVE SYSTEM

‘The Magbar’s body is constructed from Stainless-Steel (Grade A2/A4), which houses the
encapsulated electromagnetic coils and corresponding electronics. The silicon-steel core is partially
exposed to facilitate an interlock, with a separate metallic armature plate (keeper). The equipment is
supplied with a flying lead though a factory fitted gland, which requires suitable termination at
installation this can be supplied in various length cords. Optional electronics allow for integration with
different alarm and access control systems.’

THE OFFICIAL STAMP OF 

SECUREX TECHNOLOGY LTD

QA & Test Stamp

PUBLICATION: SX-LS-P7XXXXA-IOMG ISSUE: 2.0

14-09-2020

THIS DOCUMENT IS COPYRIGHT © SECUREX TECHNOLOGY
(2020).

ALL REASONABLE PRECAUTIONS HAVE BEEN TAKEN TO
ENSURE THE ACCURACY OF THE INFORMATION CONTAINED
IN THIS DOCUMENT AT THE TIME OF PUBLICATION.

IT IS THE END USERS RESPONSIBILITY TO ENSURE THAT THE
PRODUCT IS INSTALLED AND USED IN ACCORDANCE WITH
THE GUIDELINES SET OUT HEREIN.

IN CASE OF DOUBT, NEED FOR FURTHER CLARIFICATION, OR
IF ANY ERRORS OR OMMISIONS ARE FOUND PLEASE INFORM
US / CONTACT US IMMEDIATELY.

SECUREX RESERVES THE RIGHT TO CHANGE AND UPDATE
ANY AND ALL DATA FOUND IN THIS DOCUMENT & CAN
SUPPLY EQUIMPEMT WHICH IS EQUAL TO OR \gREATER IN
SPECIFACION

Summary of Contents for SecureEx SX-LS-P7 Series

Page 1: ...SX EX ELECTROMAGNETIC LOCK REVISION 2 INSTALLATION OPERATION MAINTENANCE GUIDE IOMG PART NO SX LS P7XXXXA CERTIFICATE ISSUE No 2...

Page 2: ...y products supplied either as individual components or as matched building blocks of a complete bespoke solution Products typically are CE ATEX IECEx and or UL certified for use in various gas and dus...

Page 3: ...e 6 MOUNTING OPTIONS Page 7 ELECTRICAL INSTALLATION Page 8 OPERATION Page 9 MAINTENANCE Page 10 ELECTROMAGNETIC LOCK GA Page 11 ARMATURE KEEPER GA Page 12 ATEX PRODUCT CERTIFICATE Page 15 DECLARATION...

Page 4: ...unit may be fitted to a wide variety of door configurations including left or right handed and in or outward opening doors by using the appropriate approved matching mounting systems sold separately...

Page 5: ...INSTALLATION ONLY BY APPROPRIATELY QUALIFIED PERSONNEL Installation Considerations The SX LS P7XXXXA series Electromagnetic locks can be installed and used just like a conventional electromagnetic loc...

Page 6: ...rom the door to close directly onto the lock This arrangement requires our optional custom Z bracket Note Due to common mounting points the Z bracket can also be used to mount the lock in an alternate...

Page 7: ...magnetic switch should be appropriately fused protected in line as specified by the X conditions to prevent exceeding the design limits set out in the Technical Specifications section SLO BLO is the m...

Page 8: ...d to lock product The case is specially designed to dissipate heat and acts as a natural heat sink The external temperature of the unit will therefore rise under normal use and may become hot DOOR STA...

Page 9: ...tic surfaces are kept clean and clear of debris which could impair performance Every 3 months check the external sealing of the multicore cable connections and the overall condition of the unit NOTE I...

Page 10: ...ELECTROMAGNETIC LOCK GA 10...

Page 11: ...ARMATURE KEEPER GA 11...

Page 12: ...IECEx PRODUCT CERTIFICATE 12 For IECEx Certificate of conformity please download from https www iecex certs com home Certificate number IECEx EXV 17 0018X ATEX PRODUCT CERTIFICATE...

Page 13: ...13...

Page 14: ...14...

Page 15: ...EU EC DECLARATIONS OF CONFORMITY 15...

Page 16: ...armature plate keeper The equipment is supplied with a flying lead though a factory fitted gland which requires suitable termination at installation this can be supplied in various length cords Optio...

Page 17: ...ems 1 SPCO Contact S0 STDFS 2 SEOL Grade 2 S1 3 TEOL Grade 3 S2 4 Alarm Tamper Loop S3 5 SPECIAL Contact S4 6 Tamper Loop Only S5 System specified on order Configuration only available on special requ...

Page 18: ...NOTES 18...

Page 19: ...NOTES 19...

Page 20: ...ingdom T 44 0 1709 352301 E info securex technology E Documents Electronic copies of this manual together with additional product information and copies of the IECEx ATEX certificates can be found on...

Reviews: