SPECIAL NOTE 1:
Subject to normal use, mechanical installation in
approved
configurations
and
appropriate
electrical connections having been made this
locking
system
should
respond
reliably.
Reconstruction and alterations to the lock that
might affect the explosion protection are not
allowed. Furthermore EN 60079-14 and EN
61241- 14 have to be applied for the installation
of electrical equipment in explosive areas.
Moreover the special conditions as set out in
the products ATEX / IECEx test certificates
must be observed.
SPECIAL NOTE 2:
ALL
main components of this locking system
are clearly and uniquely Serial Numbered using
tamper evident seals which are fitted for your
safety & security.
The unique serial numbering provides full
traceability for the lock kit and certified parts.
Lock sets MUST ALWAYS be used together as
a complete system.
The Cover Plate ‘Certification label face’ is
marked
on
the
GA
is
engraved
with
Configuration & Certification Details of the
specific lock unit supplied.
MECHANICAL INSTALLATION
PRODUCT ONLY SUITABLE FOR
END USER INSTALLATION ONLY
BY APPROPRIATELY QUALIFIED
PERSONNEL
Installation Considerations
The SX-LS-P7XXXXA series Electromagnetic
locks can be installed and used just like a
conventional electromagnetic lock by being
fitted onto the frame and acting on the armature
plate (keeper unit) which is usually mounted to
the top of the door.
Mechanical Installation
Basic installation requires 4 x M6 Mounting
bolts for the lock.
The Lock is provided as standard fully
assembled with a 5 m user cable factory fitted.
DOOR PREPARATION
Door preparation details are shown on the GA
drawings for the Electromagnetic Lock and
Armature (Keeper) which can be found on the
center pages of this manual.
Care MUST be taken to carefully align the lock
and armature units. This is essential both to
correctly align the door sensor system and to
ensure full engagement of the armature for
optimum performance of the lock.
Depending on the door type you are fitting the
lock to, both the door and frame will need to be
appropriately prepared, drilled and tapped. This
may require appropriate rivet nut inserts to be
fitted
or
hank
bushes
to
be
installed.
Furthermore,
depending
on
the
door
configuration, the use of approved matching
mounting systems may be required – See
Mounting Options.