background image

27

If Installation Fails

If, during USB device driver installation, some trouble occurs that results 

in  a  failure  to  install  properly,  the  following  display  will  appear  in  the 

Device Manager.

If this occurs, please re-install from the

USB Device

properties.

How to Re-install

1

.

In  the  Device  Manager Window,  right  click  on 

USB  Device

 

under 

Other Devices

 to display the USB Device Properties.

2

.

In the USB Device Properties Window, click on the 

[

Reinstall Driver

]

 

button to display the Installation Window. Follow the directions to 

install.

[

Reinstall Driver

]

button

Specifications

28

Device Type

TR-71U

TR-72U

No. of Measurement 
Channels

2 Channels

(

Select from ch1. internal

ch.2 external

)

2 Channels

(

1 Temperature

1 Humidity

)

Measurement Items

Temperature

Temperature

Humidity

Internal Temperature 
Sensor

-

10 to 60

-

10 to 60

Attached Sensor

-

40 to 110

0 to 50

10 to 95

RH

Optional Temp. Sensor

-

60 to 155

℃  ※

1

 

-

40 to 110

Measuring Accuracy

(

with Attached Sensor

)

Average

±

0.3

(-

20 to 80

)

Average

±

0.5

(-

40 to 

-

20

80 to 110

)

±

5

RH

(

at 25

 50

RH

)

Measuring

Display Resolution

0.1

1

RH

Sensor

Thermistor

Macromolecular 

Humidity Sensor

Recording Interval

Select from 15 choices: 1

2

5

10

15

20

30 seconds 

                         

1

2

5

10

15

20

30

60 minutes

Recording Capacity

8000 readings

×

2 channels

Recording Modes

Endless Mode

One-time Mode

LCD display

(

Ch1 only, Ch2 only, alternating display

)

Measurements, 

Recording Status, Battery Life Warning, Amount of Recorded Data,

Unit of Measurement

Power

AA alkaline battery 

(

LR6

)

Battery Life

About 1 year 

2

Data Backup

Activated when battery power is low or when switch is off 

(

About 1 year

)

Interface

USB Communication Cable 

(

option: RS-232C

)

USB Communication 
Time

When downloading 

(

1 unit of full data-about 8 seconds

)

Dimensions

 

Weight of Main Unit

H55

×

W78

×

D18

mm

about 62 g 

(

including one AA battery

)

Working Environment 
for Main Unit

Temperature: 

-

10 to 60

Humidity: under 90%RH 

(

without condensation

)

Attached Sensors

TR

-

0106

×

2

TR

-

3100

×

1

Accessories included in 
package

AA alkaline battery 

(

LR6

) ×

1

User's Manual 

(

Warranty

) ×

USB cable

×

(

US-15C ; length 1.5 m

)

Software set

×

1

User's Manual 

(

Warranty

) ×

1

1:

There are two types of temperature sensor for TR-71U depending on measurement range. For 

details see Optional Accessories

 

on p.29.

2:

Battery life depends upon the measuring environment, recording interval, and quality of the 

battery being used.

Summary of Contents for TR-71U

Page 1: ...User s Manual Thank you for purchasing our product Carefully read this instruction manual before using this unit 2004 01 16004374020...

Page 2: ...rmission of the Japanese government to be exported outside of Japan This User s Manual cannot be reissued so please keep it in a safe place Please read the warranty and provisions for free repair care...

Page 3: ...top using Continued use may cause fire or electrocution Condensation may occur if the unit is moved from one environment to another where the difference in temperature is great Use the unit in an envi...

Page 4: ...r batteries than those that are specified in this User s Manual It may cause a fire or other trouble including malfunction CAUTIONS The possible temperature measurement range for this sensor is 40 to...

Page 5: ...ickers shows abnormality you should change the old sensor to a new one immediately Cautions about using the Sensors Wetness Detection Sticker Temperature Detection Sticker Wetness Detection Sticker In...

Page 6: ...d Specifications and explanations used in this User s Manual are based on operations carried out with a new battery and are in no way a guarantee of your actual battery life Battery Life Warning Displ...

Page 7: ...t Software User s Manual 1 AA Alkaline Battery LR6 1 USB Communication Cable US 15C 1 T D Recorder for Windows Software CD ROM 1 TR 72U USB Communication Cable US 15C 1 AA Alkaline Battery LR6 1 Tempe...

Page 8: ...2000 readings the scale will be marked from left to right COM Mark This will appear when data is being sent or received ON USB cable is connected BLINKING In communication with computer Recording Mod...

Page 9: ...o download all saved recorded data 3 If the battery is further left unchanged the display will automatically shut off If all battery power is lost all data will be lost as well NOTE If a unit is left...

Page 10: ...Driver 3 Insert the attached CD ROM in the CD ROM drive If the Installation Window opens close it For Windows XP 1 Turn on your computer and open Windows 2 After Windows has been completely started u...

Page 11: ...ger 12 3 Insert the attached CD ROM in the CR ROM drive If the Installation Window opens close it 4 By connecting a data logger to the USB cable already connected to your computer the Found New Hardwa...

Page 12: ...Next button 14 8 By clicking the Next button installation will begin 9 After completing installation click the Finish button If the Driver is not automatically detected please search by specifying th...

Page 13: ...SB Recorder COM For Windows Me 1 Turn on your computer and open Windows 2 After Windows has been completely started up connect the supplied USB cable to a USB port on your computer 3 Insert the attach...

Page 14: ...M Device Driver and install manually from there Checking After Connecting 1 Open the Control Panel and double click on System the system properties will be displayed 2 Click the Device Manager Tab and...

Page 15: ...ere you can choose how you wish to find the driver file For Windows 98 1 Turn on your computer and open Windows 2 After Windows has been completely started up connect the supplied USB cable to a USB p...

Page 16: ...place as CD ROM Device Driver and install manually from there Checking After Connecting 1 Open the Control Panel and double click on System the system properties will be displayed 2 Click the Device M...

Page 17: ...t on the surface of the sensor causing the sensor s accuracy and sensitivity to decrease If the sensor is being used in a bad environment smoky or dusty places it may be necessary to change the sensor...

Page 18: ...ng interval will be displayed 15 seconds 15 minutes By pressing the REC switch on the main unit you can start a recording session immediately If you wish to make changes to the device name channel nam...

Page 19: ...hermistor Macromolecular Humidity Sensor Recording Interval Select from 15 choices 1 2 5 10 15 20 30 seconds 1 2 5 10 15 20 30 60 minutes Recording Capacity 8000 readings 2 channels Recording Modes En...

Page 20: ...nstant Time In the air Approx 75 Sec TR 0206 Stainless Protection Sensor Cable Length 0 6m Thermal Constant Time In the air Approx 75 Sec Materials Thermistor TPE resin shielded sensor TPE resin shiel...

Page 21: ...ble Temp Sensor Only TR 1C30 Cable length 3 0m Materials Vinyl Coated Electrical Wire unit millimeters Materials Temperture humidity sensor Polypropylene resin Vinyl Coated Electrical Wire Possible te...

Page 22: ...to the dealer A service charge may be added if a repairperson must be sent out to the place of use for repair 3 If you have moved after purchasing or the product was received as a gift or there are d...

Reviews: