background image

1

About Thermo Recorder TR-71U

/

72U

Outline

TR-71U

/

TR-72U Thermo  Recorders  are  data  loggers  capable  of 

measuring,  displaying  and  recording  temperature  and  humidity  data. 

TR-71U has two temperature channels and TR-72U has one temperature 

and one humidity channel. The data recorded into the TR-71U

/

TR-72U 

units can then be downloaded quickly via USB cable to your computer 

whereby with our exclusive software you can easily process the data into 

graphs, tables, save to files and/or print it out. Moreover, it is possible to 

connect more than one unit at the same time.

Basic Functions

Temperature Measuring Range : 

-

60 to 155

℃(

TR-71U

)

The TR-71U  with  the  sensor  included  in  this  package  can  measure  and 

record in a range of 

-

40 to 110

, but by purchasing one of our optional 

sensors it is possible to measure and record in the wider range of 

-

60 to 

155

. Please take a look at our full range of optional sensors to find one to 

match your application.

Humidity Measuring Range : 10 to 95

RH

TR-72U

)

The TR-72U  with  the  sensor  included  in  this  package  can  simultaneously 

measure and record temperature in a range of 0 to 50

 and humidity in a 

range of 10 to 95

RH.

Data Recording Capacity : 8000 readings

×

2 channels

One channel can record and hold up to 8000 measurement readings.  If set 

at  a  recording  interval  of  1  hour,  a  unit  can  continuously  record  for  about 

one year.

1 Year of Operation with just 1 AA Alkaline Battery

Our  low  energy  consumption  design  gives  you  one  year  of  continuous 

operation with only one AA alkaline battery. This gives you the freedom to 

use the data loggers in places where they can be left alone for long periods 

of time, such as, in transportation or refrigeration.

Note:

 Battery life varies depending upon the type of battery, the measuring 

environment, the frequency of communication, and the ambient temperature 

in  which  it  is  used.  Specifications  and  explanations  used  in  this  User's 

Manual are based on operations carried out with a new battery and are in 

no way a guarantee of your actual battery life.

Battery Life Warning Display

When  the  battery  power  becomes  low,  a  battery  life  warning  signal  will 

appear in the unit’s LCD display. If the battery power becomes even lower 

the unit will automatically go into sleep mode in order to protect the data.

15 Recording Intervals

Select from 15 Recording Intervals 

(

from 1 second to 1 hour

)

 to meet your 

needs. Select from 2 Recording Modes
 One-time Mode : When  the  number  of  recorded  readings  reaches  8000,
 

  "

FULL" will appear in the unit’s LCD display and recording 

 

  will automatically stop.

  Endless Mode : When the number of recorded readings reaches 8000, the

 

  oldest  data  reading  will  be  overwritten  and  recording  will

 

  continue. 

Backup Function

When battery power becomes low, a battery life warning signal will appear 

in the unit’s LCD display and if the battery power becomes even lower the 

unit  will  automatically  go  into  sleep  mode  in  order  to  protect  the  data.  In 

sleep mode all normal operations will stop and it will become impossible to 

switch on the power of the main unit. 

Note:

 If the main unit remains in sleep mode for about 1 month without a 

change  of  battery,  or  if  the  battery  is  left  out  of  the  unit  for  more  than  2 

minutes, all recorded data will be lost. 

Current Readings Monitoring Display

With  our  exclusive  software,  you  cannot  only  monitor  the  current 

measurements  at  a  set  interval,  but  can  view  those  measurements  in  a 

continually  changing  graph. You  can  simultaneously  display  the  current 

measurements and corresponding graphs for the number of units you have 

connected. 

Adjustment Function

Bt  setting  adjustment  values  beforehand,  you  can  record  and  display  the 

post

-

adjusted  measurement  values. You  can  choose  from  two  adjustment 

methods:  1-point  and  2

-

point.  Adjustment  will  be  carried  out  using  an 

adjustment equation of Y

aX

b ; where X is the pre-adjusted measurement 

value and Y is the post-adjusted value. 

Summary of Contents for TR-71U

Page 1: ...User s Manual Thank you for purchasing our product Carefully read this instruction manual before using this unit 2004 01 16004374020...

Page 2: ...rmission of the Japanese government to be exported outside of Japan This User s Manual cannot be reissued so please keep it in a safe place Please read the warranty and provisions for free repair care...

Page 3: ...top using Continued use may cause fire or electrocution Condensation may occur if the unit is moved from one environment to another where the difference in temperature is great Use the unit in an envi...

Page 4: ...r batteries than those that are specified in this User s Manual It may cause a fire or other trouble including malfunction CAUTIONS The possible temperature measurement range for this sensor is 40 to...

Page 5: ...ickers shows abnormality you should change the old sensor to a new one immediately Cautions about using the Sensors Wetness Detection Sticker Temperature Detection Sticker Wetness Detection Sticker In...

Page 6: ...d Specifications and explanations used in this User s Manual are based on operations carried out with a new battery and are in no way a guarantee of your actual battery life Battery Life Warning Displ...

Page 7: ...t Software User s Manual 1 AA Alkaline Battery LR6 1 USB Communication Cable US 15C 1 T D Recorder for Windows Software CD ROM 1 TR 72U USB Communication Cable US 15C 1 AA Alkaline Battery LR6 1 Tempe...

Page 8: ...2000 readings the scale will be marked from left to right COM Mark This will appear when data is being sent or received ON USB cable is connected BLINKING In communication with computer Recording Mod...

Page 9: ...o download all saved recorded data 3 If the battery is further left unchanged the display will automatically shut off If all battery power is lost all data will be lost as well NOTE If a unit is left...

Page 10: ...Driver 3 Insert the attached CD ROM in the CD ROM drive If the Installation Window opens close it For Windows XP 1 Turn on your computer and open Windows 2 After Windows has been completely started u...

Page 11: ...ger 12 3 Insert the attached CD ROM in the CR ROM drive If the Installation Window opens close it 4 By connecting a data logger to the USB cable already connected to your computer the Found New Hardwa...

Page 12: ...Next button 14 8 By clicking the Next button installation will begin 9 After completing installation click the Finish button If the Driver is not automatically detected please search by specifying th...

Page 13: ...SB Recorder COM For Windows Me 1 Turn on your computer and open Windows 2 After Windows has been completely started up connect the supplied USB cable to a USB port on your computer 3 Insert the attach...

Page 14: ...M Device Driver and install manually from there Checking After Connecting 1 Open the Control Panel and double click on System the system properties will be displayed 2 Click the Device Manager Tab and...

Page 15: ...ere you can choose how you wish to find the driver file For Windows 98 1 Turn on your computer and open Windows 2 After Windows has been completely started up connect the supplied USB cable to a USB p...

Page 16: ...place as CD ROM Device Driver and install manually from there Checking After Connecting 1 Open the Control Panel and double click on System the system properties will be displayed 2 Click the Device M...

Page 17: ...t on the surface of the sensor causing the sensor s accuracy and sensitivity to decrease If the sensor is being used in a bad environment smoky or dusty places it may be necessary to change the sensor...

Page 18: ...ng interval will be displayed 15 seconds 15 minutes By pressing the REC switch on the main unit you can start a recording session immediately If you wish to make changes to the device name channel nam...

Page 19: ...hermistor Macromolecular Humidity Sensor Recording Interval Select from 15 choices 1 2 5 10 15 20 30 seconds 1 2 5 10 15 20 30 60 minutes Recording Capacity 8000 readings 2 channels Recording Modes En...

Page 20: ...nstant Time In the air Approx 75 Sec TR 0206 Stainless Protection Sensor Cable Length 0 6m Thermal Constant Time In the air Approx 75 Sec Materials Thermistor TPE resin shielded sensor TPE resin shiel...

Page 21: ...ble Temp Sensor Only TR 1C30 Cable length 3 0m Materials Vinyl Coated Electrical Wire unit millimeters Materials Temperture humidity sensor Polypropylene resin Vinyl Coated Electrical Wire Possible te...

Page 22: ...to the dealer A service charge may be added if a repairperson must be sent out to the place of use for repair 3 If you have moved after purchasing or the product was received as a gift or there are d...

Reviews: