background image

31 

Click the [Print] button to start printing.

Saving Recorded Data as Text for use with Spreadsheet Software

It is possible to convert recorded data to a text file (CSV format) which can be 

read by common spreadsheet software.

11 

While the graph is open, click [Save Data in Text File] in the [File] Menu.

21 

After having made the desired settings, click the [OK] button.

31 

Make storage folder and file name settings, and click the [Save] button to output 
the file.

Specifications

TR-76Ui

TR-76Ui-S

Temperature-Humidity Sensor (External)

Sensor

THA-3001

SHA-3151(High-Precision Type)

Thermistor

Polymer Resistance

Thermistor

Polymer Resistance

Measurement 
Channels

Temperature 1ch

Humidity 1ch

Temperature 1ch

Humidity 1ch

Units of 
Measurement

°C, °F

%RH

°C, °F

%RH

Measurement 
Range (*1)

0 to 55 °C

10 to 95 %RH

-25 to 70 °C

0 to 99 %RH (*2)

Accuracy

±0.5 °C

±5 %RH
  at 25 °C, 50 %RH

±0.3°C 
  at 10 to 40 °C
±0.5°C 
  all other temperatures

±2.5 %RH 
  at 15 to 35 °C, 30 to 80 %RH

Measurement 
Resolution

0.1 °C

1 %RH

0.1 °C

0.1 %RH

Responsiveness

Response Time (90%): Approx. 7 min.

Response Time (90%): Approx. 7 min.

CO2 Sensor (Internal)

Sensor

NDIR

Measurement Channels

CO2 Concentration 1ch

Units of Measurement

ppm

Measurement Range

0 to 9,999 ppm

Accuracy

±(50 ppm + 5 % of reading)  at 5,000 ppm or less (*3)

Measurement Resolution

Minimum of 1 ppm

Responsiveness

Response Time (90%): Approx. 1 min.

Unit Specifications 

Logging Capacity

8,000 data sets (One data set consists of readings for all channels in that type of unit.)

Recording Interval

Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min.

Recording Mode

Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full)

Communication Interfaces

USB Communication
Infrared Communication: IrPHY 1.2 low power (*4)
Serial Communication: RS-232C (*5)

External Alarm Terminal 
(*6)

Output Terminal: Open Drain Output (Voltage when OFF: DC less than 30V / Current when ON: less than 0.1A / 

Resistance when ON: about 15Ω)

Power

AC Adaptor (AD-06A1 or AD-06C1), AA Alkaline Battery x 4

Battery Life

Approx. 2 days ( batteries only without AC adaptor )  (*7)

Dimensions

H 96 mm × W 66 mm × D 46 mm ( excluding protrusions and sensor )

Weight

Approx. 120 g

Operating Environment

Temperature: 0 to 45 °C, Humidity: 90 %RH or less ( no condensation )

Initial Settings

Recording Mode: Endless, Recording Interval: 10 min.

CO2 Recorder for Windows

Compatible OS (*8)

Microsoft Windows 10 32/64 bit
Microsoft Windows 8 32/64 bit
Microsoft Windows 7 32/64 bit 
Microsoft Windows Vista 32 bit (SP1 or later) 

Display Languages (*9)

English

*1: 

Make sure to use the data logger within the operating environment as listed in the specifications.

*2: When continually used in environments with temperatures above 60°C,  accuracy of humidity measurements will decrease over time. Also, humidity cannot 

be measured at temperatures below -20°C.

*3: Stated value is the measurement accuracy of the CO2 sensor when Auto Calibration is operating properly. A change in atmospheric pressure directly 

influences the reading of CO2, which can cause measurement errors; a decrease in pressure by 10 hPa results in a relative decrease in CO2 by 1.6%. In 

such a case, we recommend carrying out the “Atmospheric Pressure Correction” function found in CO2 Recorder for Windows.

*4: If you wish to use infrared communication to download recorded data, it is necessary to purchase the Data Collector TR-57DCi (sold separately).
*5: 

Customers wishing to write their own software, please contact your local distributor for the serial communications protocol specifications. (Note: Optional 

serial communication cable TR-07C is also required.)

*6: In order to use the external alarm terminal, please prepare a compatible connector: JST PAP-04V-S.
*7: Battery life varies depending upon the ambient temperature in which it is used, the recording interval, the frequency of communication, and the battery 

performance. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life. Battery life may be 

shortened if the unit is used under inverter type fluorescent lighting.

*8: For installation, it is necessary to have Administrator (Computer Administrator) rights.
*9: We recommend using an operating system in the same language as the display language. Operation in different languages is not guaranteed.

The specifications listed above are subject to change without notice.

Cautions about using the Temperature-Humidity Sensors

 

-

If extremely severe temperature changes occur, the humidity measurements may appear abnormal. Once the sensor’s temperature 
becomes stable, the measurements will return to normal.

 

-

Do not connect the sensor to any data logger other than those specified by T&D Corporation.

 

-

Do not expose the sensor to a strong impact. This may adversely affect measurement accuracy and cause damage or malfunction.

 

-

When the sensor is not to be used for a long period of time, please store it at normal temperature and humidity.

 

-

Do not allow the sensor to become wet. If the sensor gets wet, immediately remove it from the unit.

 

-

Do not use the sensor on the human body.

 

-

Do not expose to condensation, dampness, corrosive gases, or organic solvents.

 

-

Continued use may cause a decrease in the sensor’s accuracy and sensitivity even under normal operational conditions. If the 
sensor is being used in a bad environment (smoky or dusty places) it may be necessary to change the sensor sooner.

 

-

The SHA-3151 is not water resistant. If the sensor gets wet, immediately remove the sensor from the unit and wipe it with a clean 
cloth as soon as possible. Then allow the sensor to dry in normal room temperature before using it again.

 

-

When using the THA-3001/3151 in an environment where the humidity is under 30%RH, the measurements may sometimes 

fluctuate. This is not abnormal.

Options

Data Collector: TR-57DCi

Wall Attachment: AT-76K1

For Infrared Communication

Accessories

USB Communication Cable (US-15C)

Serial Communication Cable (TR-6C10)

AAA Alkaline Battery x 2

Software CD-ROM

Material: Aluminum

Temperature-Humidity Sensor : THA-3151

Sensor Extension Cable: TR-1C30

Measurement Range: 

Temperature: 0 to 55 °C / Humidity 10 to 95 %RH (No condensation)

Cable Length: 1.5 m

For Temperature-Humidity Sensor  THA-3001/3151, SHA-3151

(Possible to use up to three extension cables per sensor)

Cable Length: 3m

Temperature Durability: -25 to 60 °C 

Material: Vinyl Coated Electrical Wire

 Install the Software

For installation of the supplied software, it is necessary to have Administrator (Computer 

Administrator) rights.

11 

Start Windows and place the CD-ROM into your CD or DVD drive.

21 

In a few seconds, the [Install Program] window will appear.

 

If the [Auto Play] window appears, click on 

[Run start.exe].

 

If the [Install Program] window does not 

automatically open, please open it by double 

clicking on the [start.exe] icon in your CD or 

DVD drive.

31 

Select “Install CO2 Recorder for Windows” and click the [Execute] button to start 
the installation. Follow the directions to install.

41 

If a window appears such as the one below during installation, click the [Install] 
button.

51 

After installation, "CO2 Recorder for Windows" will appear in the Windows Start 
Screen or Start Menu.

 Connect the TR-76Ui to a PC

11 

Connect the device with the supplied USB cable to your computer.  
The USB driver installation will start automatically.

 

It is not necessary to connect AC adaptor at this point.

21 

Open CO2 Recorder for Windows and confirm that the TR-76Ui icon appears in the 

main window.

 

If the icon does not appear, please check whether the USB driver has been properly installed. 

(Refer to  [  Help for Unit Recognition Failure] )

 Make Atmospheric Pressure Correction Settings

Measurement results of CO2 concentration are affected by atmospheric 

pressure. When high measurement accuracy is required, we recommend that 

Atmospheric Pressure Correction be carried out before a recording session is 

started.

11 

Connect a TR-76Ui to your PC and open CO2 Recorder for Windows.

21 

From the [Settings] Menu, select [Atmospheric Pressure Correction] to open the 
settings window.

Enter Atmospheric Pressure at Measurement 

Location:

Directly enter the pressure (hpa) in the [Atmospheric 

Pressure] field.

Calculate Atmospheric Pressure from Altitude:

This setting can also be made by having the 

software calculate the estimated pressure at the 

altitude (meters) entered by the user.

31 

Click the [Send Settings] button to transmit the settings to the TR-76Ui.

 Make Settings and Start Recording

Upon the start of recording, all previously recorded data in the TR-76Ui will be deleted.

11 

Connect a TR-76Ui to your PC and open CO2 Recorder for Windows.

21 

Make recording settings in the [Start 
Recording] tab window.

31 

Click the [Start Recording] button to 
transmit the settings to the TR-76Ui.

41 

Disconnect the TR-76Ui from the PC and place in the desired measurement 
location.

Recording Settings

Recording Start Date and Time

Programmed Start:

Recording will begin on the set date and time. As the current date and time of your 

computer are used, make sure that your computer clock settings are correct.

Immediate Start:

Recording will start when the [Start Recording] button is clicked.

Recording Mode

One Time:

Upon reaching the logging capacity of 8,000 readings, recording will automatically stop.

Endless:

Upon reaching the logging capacity of 8,000 readings, the oldest data will be overwritten 

and recording will continue.

Recording Interval

There are 15 choices for the recording interval. 

Below are some examples of recording interval and maximum recording time.

1 second

(2 hr 13 min 20 sec)

10 minutes

(55 days 13 hr 20 min 00 sec)

30 seconds

(2 days 18 hr 40 min 00 sec)

15 minutes

(83 days 8 hr 00 min 00 sec)

1 minute

(5 days 13 hr 20 min 00 sec)

30 minutes

(166 days 16 hr 00 min 00 sec)

5 minutes

(27 days 18 hr 40 min 00 sec)

60 minutes

(333 days 8 hr 00 min 00 sec)

 Download Recorded Data to a PC

Even after downloading recorded data, the data will remain in the TR-76Ui.

11 

Connect a TR-76Ui to your PC and open CO2 Recorder for Windows.

21 

In the [Download Recorded Data] tab window, click the [Download] button.

Here you can check the storage location 

and file name for the recorded data.

31 

When a completion message appears after downloading, click the [OK] button to 
view the graph for that data.

Storage Location of Recorded Data and File Name 

(Default Settings)

Documents (or My Documents)\TandD Corp\ 

CO2 Recorder for Windows\Internal ID(folder)\ 

Internal ID*+ Downloading Date and Time.thc

 

* Internal ID is a unique number assigned to each product, which can 

be found on the sticker on the reverse side of the product.

 View and Print Graphs

Viewing Saved Data in Graph Form

11 

Open the Multi-scale Graph. From the [File] Menu, select [Open]. 

21 

Select the data file you wish to open, and click [Open] to view in graph.

Printing the Graph

11 

While the graph is open, click [Graph Print Preview] in the [File] Menu to view a 
preview image of the printed page.

21 

If you wish to change the aspect ratio of the graph, change the size of the graph 
window.

For more detailed information

Operation Guide:

Operation Guide contains detailed information about basic settings as well as details 

about advanced settings for many useful functions.  Access if from the Start Screen/Menu 

or from the [Help] button in the application window.

Help for Unit Recognition Failure:

[Help for Unit Recognition Failure] contains detailed information about installing and 

checking the USB driver as mentioned in [Using the Software :  

 ].  Access is via the 

[Help] menu in CO2 Recorder for Windows.

 

 Auto Calibration Function for CO2 Sensor 

What is "Auto Calibration" ?

Auto calibration is a function designed to enable long-term accurate 
measurements for the TR-76Ui by gradually adjusting the lowest measured 
CO2 concentration over a 180 hour period, to the global average 
concentration (atmospheric CO2 level of 400 ppm).

 

The factory default setting for auto calibration is ON.

Turning ON and OFF Auto Calibration

Turn off auto calibration (*1) when continuously measuring in an environment 
where the lowest CO2 concentration differs greatly from the global average 
concentration of 400 ppm. 
In this case, to ensure accurate measurement results, periodically place the 
TR-76Ui in fresh air outside and check if the measured CO2 concentration 
values are close to 400 ppm or not. If not, we recommend that you carry out 
manual calibration (*2).

*1:  The factory default setting for auto calibration is enabled. To change this setting, go to the 

[Settings] menu and select [Auto Calibration Settings].

*2:  The measurement of the CO2 sensor may have a slow drift. It is recommended to perform manual 

calibration about once a month. For details about manual calibration, please refer to [Operation 
Guide]- [Available Settings] .

Using the Software

Do not connect a TR-76Ui to your computer until the software has been installed1

Reviews: