POSSIBLE CAUSE
REC O M M
E N D E D A C T ION
S ECTIO N
CO NDIT I O N
4.1
NOT READY
AND/OR
NO INDEX
Diskette not inserted.
Diskette not clamped.
Unit not selected.
Insert diskette.
Turn knob lock lever
clockwise so that it
is perpendicular to
the diskette insertion slot.
Verify unit select and
jumper configuration.
Verify interface drive motor on.
Check Connector P6.
Verify drive belt installed
Replace circuit board.
Replace Drive Motor Assembly.
Drive motor not turning
Index sensor not
connected.
Index sensor defective.
Check P1.
Replace index sensor.
4.2
WILL NOT SEE K
Int e r f a c e not enabled.
OR RESTORE
Verify interface direction,
step, and select signals.
Check Connectors P4 and P5.
Replace circuit board.
Step motor disconnected.
Defective step logic.
Defective stepper motor .
Re p l a c e Stepper Motor Assembly.
Wrong option selected.
Check options DS and HL for the
particular application.
4-2
Summary of Contents for TM848-1
Page 32: ...HUB CENTER LINE TRACK 0 TRACK 38 TRACK 76 Figure 2 2 Hub Center Line and Track Locations 2 3 ...
Page 81: ...APPENDIX I PRINTED CIRCUIT BOARD S CHEM A T ICS AND ASSEM B LY DRAW IN G S ...
Page 88: ...APPENDIX II RECOM M E N D E D SPARE PARTS LIST ...
Page 90: ...Pi N 1 79031 001 1 082 ...