background image

17

Care Instructions

CARING FOR YOUR WATER HEATER

Care and Cleaning

DANGER:

 Shock Hazard – Make certain 

power to the water heater is OFF before removing 

protective cover for any reason. Electric shock will cause 

death or serious personal injury.

WARNING:

 Combustible materials, such as 

clothing, cleaning materials, or flammable liquids, must 

not be placed against or next to the water heater. Fire or 

explosion can occur causing death, personal injury, and/

or product damage.

All care and cleaning to and around the water heater 

should only be performed with the water heater turned 

off and the electrical power supply disconnected.

 

  Vacuum around the water heater to remove any dust, 

dirt, and/or lint buildup.

 

 

   Clean the water heater and the remote control with a 

damp soft cloth and mild detergent. Gently wipe and 

completely dry all surfaces.

 

 

 Check the air intake and vent outlet for blockage and/

or debris.  

NOTICE:

 The air intake requires a minimum of 12 

in. (30 cm) of clearance between the air intake opening 

and any obstruction.
Clean the water filter monthly, as described below and on 

page 18.

Water Filter Cleaning

  Turn off the water heater and disconnect the electrical 

power supply.

  Turn off the water supply to the water heater.

 

  Drain the water heater. See page 20.

1

2

3

1

Drain Valve

3

Cold Water Supply

Shut-Off Valve

2

Outdoor models

Summary of Contents for 000 Btu/hr

Page 1: ...nd service must be performed by a qualified installer service agency or the gas supplier What to Do If You Smell Gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Do not return t...

Page 2: ... Safety Information This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER WARNING CAUTION or NOTICE 2 These words mean IMPORTANTSAFETYINFORMATION This water heater is not suitable for use in manufactured mobile homes Improper installation adjustment alteration service or maintenance can ca...

Page 3: ...of a water heater or any other appliance Be sure to read and follow the labels on the water heater as well as the warnings printed in this manual Failure to do so can result in death bodily injury or property damage Combustible construction refers to adjacent walls and ceilings and should not be confused with combustible or flammable products and materials Combustible materials such as clothing cl...

Page 4: ...c heat tracing or equivalent to prevent freezing of the pipes DO NOT insulate or block the drain valve on the hot outlet fitting If the pipes are allowed to freeze the water heater and the pipes may malfunction or leak due to freezing water Failure to drain the water heater as described on page 20 can cause serious personal injuries from scalding and or damage the water heater Time Temperature Rel...

Page 5: ... result in death or serious personal injury from fire and or explosion This water heater is not certified for any other fuel type Both natural gas and propane LP have an odorant added to aid in detecting a gas leak Some people may not physically be able to smell or recognize this odorant If you are unsure or unfamiliar with the smell of natural gas or LP ask the gas supplier Other conditions such ...

Page 6: ... this label 2 Turn off all electric power to the appliance 3 Do not attempt to light the burner by hand 4 Turn the Gas Shutoff Valve located on the outside of the unit clockwise to the OFF position 5 Wait five 5 minutes to clear out any gas If you then smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 6 Turn the Gas Shutoff Valve locat...

Page 7: ...ice personnel Make certain the power to the water heater is OFF before removing the unit cover panel Exposed electrical components and moving parts can cause personal injuries For your safety DO NOT attempt repair of electrical wiring gas piping remote control burners vent connectors or other safety devices Refer repairs to qualified service personnel California law requires that water heaters mus...

Page 8: ...ails to shut off Be sure your water heater is properly installed in accordance with local codes and the provided installation instructions DO NOT attempt to repair or replace any part of your water heater unless it is specifically recommended in this manual All other servicing should be referred to a qualified service technician PRODUCTINFORMATION Read This Manual Inside you will find many helpful...

Page 9: ...131 mm 55 8 143 mm 55 8 143 mm 51 2 140 mm 43 16 106 mm 33 8 86 mm 35 8 92 mm 131 2 343 mm 63 4 172 mm 91 2 241 mm Specifications Direct Vent Models 1315 16 354 mm 2613 16 663 mm 233 4 603 mm 81 2 216 mm 19 16 40 mm 13 4 45 mm 55 8 143 mm 55 8 143 mm 43 16 106 mm 27 8 73 mm 21 16 53 mm 21 4 58 mm 131 2 343 mm 1315 16 354 mm 2613 16 663 mm 233 4 603 mm 81 2 216 mm 19 16 40 mm 13 4 45 mm 55 8 143 mm...

Page 10: ...ater Type E Installation Type F Type of Gas G Max Inlet Gas Pressure H Min Inlet Gas Pressure J Recovery Rating K Max BTU Input Rating L Min BTU Input Rating M Manifold Gas Pressure N Certification Stamp P Alternate Approval Stamp Q Clearances Specifications PRODUCTINFORMATION Product Information English Rating Label English French Rating Label ...

Page 11: ...rain Valve Water Filter Cold Water Supply Shut Off Valve Discharge Line To Suitable Drain Power Supply Cord Union Union Manual Gas Supply Line Shut Off Valve Manual Gas Shut Off Valve Cap Sediment Trap in accordance with the local gas authority Relief Valve 6 150 mm Air Gap Service Valve Condensate Collector To Drain Dispose of condensate in accordance with local codes ...

Page 12: ...s Supply Line Shut Off Valve Flue Terminal Cap Relief Valve 6 150 mm Air Gap Manual Gas Shut Off Valve Union Power Supply Cord not supplied Hard Wire Sediment Trap in accordance with the local gas authority This water heater is for OUTDOOR installation only DANGER DO NOT install this water heater indoors or in a confined area It is designed for outdoor installation only Any other type of installat...

Page 13: ...m scalds Children disabled and elderly are at highest risk of being scalded See instruction manual before setting temperature at water heater Feel water before bathing or showering Temperature limiting valves are available see manual BURN F Time Temperature Relationship in Scalds 120 F 49 C More than 5 minutes 125 F 52 C 1 1 2 to 2 minutes 130 F 54 C About 30 seconds 135 F 57 C About 10 seconds 14...

Page 14: ...rate with a small water flow Increase the water flow and recheck If it still does not operate with the hot water faucet completely open increase the temperature setting on the remote control Water Heater Facts DANGER Water temperatures above 125 F 52 C will result in death and or severe burns from scalding The hottest temperature water will be at the faucet closest to the water heater Always remem...

Page 15: ...d lead to death personal injury and or product failure Check the air intake and vent outlet for blockage and or debris Condensate Trap Direct Vent Only CAUTION DO NOT operate without the condensate trap connected to the vent and routed to the proper drain It could cause the system to malfunction or fail On a regular basis inspect the condensate trap to ensure there is enough water in the trap and ...

Page 16: ...rn on a hot water faucet While the water heater is operating inspect the main burner flames through the burner sight glass The flames should be blue when the main burner is firing NOTICE If the flames are not blue or you observe unusual burner operation shut off the water heater and contact a qualified service technician Turn off the hot water faucet and reinstall the unit cover panel 4 Burner Sig...

Page 17: ...er turned off and the electrical power supply disconnected Vacuum around the water heater to remove any dust dirt and or lint buildup Clean the water heater and the remote control with a damp soft cloth and mild detergent Gently wipe and completely dry all surfaces Check the air intake and vent outlet for blockage and or debris NOTICE The air intake requires a minimum of 12 in 30 cm of clearance b...

Page 18: ...water filter under running water To remove severe sediment and dirt use a soft brush CAUTION DO NOT overtighten the water filter Overtightening can deform and or damage the filter Replace the filter in the cold water inlet line and tighten until it is snug Turn on the water supply reconnect the electrical supply and turn on the water heater 4 7 5 6 CARINGFORYOURWATERHEATER Care Instructions Care a...

Page 19: ... drain After several gallons have drained release the lever handle to close the valve and stop draining NOTICE If the pressure relief valve on the hot water heater discharges periodically this may indicate a problem in the water system Contact the water supplier or a plumbing contractor to correct the problem DO NOT plug the relief valve outlet Inspect and keep the area around the water heater cle...

Page 20: ...breaker box Open all hot water faucets Run the water until it is COLD then shut off the faucet Close the water shut off valve Using a suitable container to catch the water remove the water filter from the base of the cold water inlet line Connect a garden hose to the drain valve in the hot water outlet line and place the other end in a suitable drain Open the drain valve until all the water has dr...

Page 21: ...d To put the water heater back in service Disconnect drain hose Make sure the drain valve is closed Reinstall the water filter in the base of the cold water inlet line Open the water shut off valve Open all hot water faucets and let run until all air has been purged from the lines Plug in the power cord or reconnect the power supply at the circuit breaker box Open the gas shut off valve s Press th...

Page 22: ...er heater down to an ambient temperature of approximately 30 F 34 C These temperatures are all based on temperatures without wind The heater only protects the internal components of the water heater NOTICE Unplugging or disconnecting the power supply to the water heater will also disconnect the power to the heater External piping and valves require additional freeze protection One method is to wra...

Page 23: ...ible Cause Solution Not enough or no hot water 1 Unit is not ON 1 Turn on the unit by pressing the POWER ON OFF button 2 Water shut off valve is not completely opened 2 Check shut off valve and open completely 3 Hot water faucet is not completely opened 3 Open hot water faucet completely The main burner goes off when incoming water volume is inadequate 4 Water piping is frozen 4 Allow piping to th...

Page 24: ...fixtures 4 Contact a dealer or a qualified service technician Water too hot 1 Temperature is set too high 1 Decrease the temperature setting at the remote control 2 Water shut off valve is not completely opened 2 Check and completely open the water shut off valve 3 Small amount of water has been heated 3 Increase the hot water flow at the faucet to allow more water to flow through the water heater...

Page 25: ...epairs to a qualified service technician When an error code is displayed Turn off all the hot water faucets Turn off the water heater by pressing the POWER ON OFF button on the remote control Wait about 5 minutes then restart the water heater by pressing the POWER ON OFF button Turn on a hot water faucet and recheck the remote control display If the error code remains in the display 1 Turn off the...

Page 26: ...roblem along with dates of service Error Code Possible Cause Solution 1L Water heater has buildup of lime deposits Contact a dealer or qualified service technician 05 Air intake or vent exhaust opening may be blocked Remove any blockage Air intake requires 12 in 30 cm of clearance The vent pipes on the vent termination may not be connected properly Contact a dealer or qualified service technician ...

Page 27: ...INSTALLATION INSTRUCTIONS FOR THE CONTRACTOR Installation ...

Page 28: ...s solvents or removers Flammable vapors carry long distances from where they are used or stored The open flame of the water heater s main burner can ignite these vapors causing an explosion or fire NOTICE Elevating a gas fired water heater will reduce but NOT eliminate the possibility of lighting the vapor of flammable liquids which may be improperly stored or accidentally spilled NOTICE This wate...

Page 29: ...allation DO NOT install the water heater where it is subject to vibrations DO NOT install the water heater in a recreational vehicle mobile home boat or other watercraft DO NOT install the water heater near vents for heating and cooling If necessary maintain a minimum clearance of 4 ft 1 2 m Minimum water heater clearances from combustible and noncombustible construction are as follows 1 2 in 1 3 ...

Page 30: ...owing locations beauty shops dry cleaning establishments photo processing labs and storage areas for liquid and powdered bleaches or swimming pool chemicals These locations often contain such halogenated hydrocarbons The air supply containing halogenated hydrocarbons is safe to breathe but when passed through a gas flame corrosive elements are released that will shorten the life of any gas burning...

Page 31: ... Heater Venting Required Relief Valve Service Valve Service Valve To Hot Water Faucet s Drain Valve Wall Plate Vent Termination With Protective Screen Water Filter Cold Water Supply Shut Off Valve Discharge Line To Suitable Drain Power Supply Cord Manual Gas Supply Line Shut Off Valve 1 4 Per Foot Downward Slope recommended Manual Gas Shut Off Valve Union Cap Sediment Trap Outside Wall 90 Elbow 6 ...

Page 32: ...ot Water Service Valve Hot Water Service Valve Pressure Relief Valve Relief Valve Water Outlet Water Outlet Water Inlet Water Inlet Drain Drain Alternate Water Piping Arrangement With Preferred Valve Kit A valve kit is available and can be used with all models See Water Supply Connections on page 46 for installation instructions Relief Valve Service Valve Service Valve To Hot Water Faucet s Drain ...

Page 33: ...concrete wall use lag bolts designed for concrete Make sure the proper electrical outlet or supply 120 VAC 60 Hz is available and located near the unit Direct vent models come with a 6 ft 1 8 m power cord while the outdoor models require hard wiring or the addition of a plug Position the upper mounting bracket and partially install the center mounting screw The clearance between the screw head and...

Page 34: ...acturer approved Stainless Steel Venting Material e g 444 SS 316 L Outer casing can be galvanized aluminum or other material The specified vent termination must be used Refer to page 45 for an example of concentric vent CAUTION DO NOT attempt to fabricate or adapt other vent pipe or materials to this venting Use the provided screws to connect the coaxial vent pipe together Follow the vent manufact...

Page 35: ...ovisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less ...

Page 36: ...pe on the vent termination is not acceptable for horizontal venting without using the condensate collector Minimum Vent Length The venting may be as short as 12 in 30 cm provided one vent termination is installed to the outdoors through a sidewall with one 90 elbow and one wall plate included in the installation Total equivalent vent length is 30 in 76 cm NOTICE Make sure that the seam of the inne...

Page 37: ...proper handling and discharge methods Condensate must be drained away from the water heater and should not be allowed to drain back into any part of the vent system The condensate collector must be used with vertical vent installation Condensate collector must be used with horizontal vent installation if the vent has an UPWARD slope toward the termination Provision should be made to collect and di...

Page 38: ...cation Outside Walls Fixed Closed Fixed Closed Operable Operable V V V V V V X X V V Inside Wall Vent Terminal Air Supply Inlet Area Where Terminal is Not Permitted B B A J I B M M F C K H V V D E B L G A X Venting for Direct Vent Water Heater cont Venting ...

Page 39: ...2 in 30 cm for water heaters greater than 50 000 Btuh 15 kW 3 6 in 15 cm for water heaters less than or equal to 10 000 Btuh 3 kW 12 in 30 cm for water heaters greater than 10 000 Btuh 3 kW and less than or equal to 100 000 Btuh 30 kW 36 in 91 cm for water heaters greater than 100 000 Btuh 30 kW K Clearance to mechanical air supply inlet 3 ft 91 cm above if within 10 ft 3 m horizontally 6 ft 1 83 ...

Page 40: ...stance between vent terminations of 19 in 48 cm for two unit installation or 21 in 53 cm for installation of three or more units Vents cannot be stacked vertically DO NOT terminate vent directly on brick or masonry surfaces A rust resistant sheet metal backing plate is recommended behind the vent Caulk all cracks seams and joints within 6 ft 1 8 m of the vent terminal Caulk around wall faceplate f...

Page 41: ...wood screws For masonry walls use suitable masonry anchors long enough to pass through the wall Reinstall the decorative sheathing around the faceplate The decorative sheathing may be painted to match the exterior decor Apply high temperature silicone sealant or silicone latex caulk around the vent section Completely seal where it passes through the wall plate and where it is attached to the struc...

Page 42: ...n page 29 A zero clearance of 0 in 0 cm is allowed between the air intake pipes and combustible material Use proper support for the vent and air intake pipes as described on page 34 Support method used should isolate the vent pipe from floor joists or other structural members This helps prevent transmission of noise and vibration DO NOT support pin or secure the venting system in a way that restri...

Page 43: ...modate the vent pipe Complete the vent pipe installation to the water heater vent collar If required use high temperature silicone sealant where the vent connector joins the water heater Support vertical and horizontal runs as described on page 36 Vertical supports are required every 4 ft 1 2 m along a vertical pipe route after every transition to vertical and after every offset elbow NOTICE Free ...

Page 44: ...now level 12 in 30 5 cm above anticipated snow level C Maximum clearance above roof level without ad ditional vent support 24 in 61 cm above roof level 24 in 61 cm above roof level D Maximum clearance above anticipated snow level requires additional vent support 24 in 61 cm above anticipated snow level 24 in 61 cm above anticipated snow level E Required vent clearance from any gable dormer or othe...

Page 45: ...tical Termination Adapter Air Intake Storm Collar Support Clamp Fire Stop To Drain Dispose of condensate in accordance to local codes Condensate Trap Fire Stop 3 to 5 Concentric Pipe Support Hanger 1 4 Per Foot Upward Slope CAUTION The condensate collector must be used with vertical vent installation ...

Page 46: ...he adapter before fitting the adapter to the water connections on the water heater Any heat applied to the water supply fittings will permanently damage the internal components of the water heater NOTICE In cold environments ice can accumulate in the water heater s connectors Plug in the water heater power cord for approximately 10 minutes before making these connections This will melt any ice bui...

Page 47: ...ng To ensure proper operation of the water heater follow these water pressure guidelines Operation of the water heater requires a minimum water pressure of 14 psi 97 kPa and a minimum activation water flow rate of 0 4 gpm 1 5 lpm Continuous operation of the water heater requires a minimum water flow rate of 0 25 gpm 1 01 lpm Water pressure of 40 psi 276 kPa is required to achieve maximum flow rate...

Page 48: ...er to be disconnected easily for servicing Use the following guidelines when connecting the HOT WATER OUTLET Connections between the water heater and point s of use should be as short as possible Local codes shall govern the piping used for water connections To conserve energy and to prevent freezing insulate both COLD and HOT water supply lines DO NOT insulate drain line or pressure relief valve ...

Page 49: ...connects to the HOT water outlet pipe as shown above The other end of the pipe should be routed to a suitable drain to eliminate potential water damage For safe operation of the water heater be sure that The pressure rating of the relief valve must not exceed 150 psi 1 034 kPa or the maximum working pressure of the water heater See the rating plate on the water heater The BTUH rating of the relief...

Page 50: ...uld result in death personal injury explosion or fire product damage and or poor operating conditions or performance NOTICES Gas piping shall be in accordance with local utility company requirements and or in the absence of local codes use the latest edition of National Fuel Gas Code NFGC ANSI Z223 1 In Canada use the latest edition of CAN CSA B149 1 Natural Gas and Propane installation code Apply...

Page 51: ...ng Value of Gas BTU FT3 Determining the required pipe size The gas system is designed to operate at a certain maxi mum pressure drop A pressure drop greater than what is permissible can cause operational issues with the gas appliances The National Fuel Gas Code NFPA 54 ANSI Z223 1 2012 allows for three pressure drop levels a 0 3 inch W C see table 2 a 0 5 inch W C see table 3 and a 3 0 inch W C se...

Page 52: ...s chart obtained from NFPA 54 ANSI Z223 1 2012 Table 6 3 d Table 2 Pipe Sizing Natural Gas Schedule 40 Metallic Pipe Black Iron Inlet System Pressure Less than 2 PSI 55 inches W C Allowable Pressure Drop 0 3 inches W C Specific Gravity 0 60 Capacity in cubic feet per hour Length Pipe Size Inches 1 1 1 10 131 273 514 1 060 1 580 20 90 188 355 726 1 090 30 72 151 284 583 873 40 62 129 243 499 747 50...

Page 53: ...as shut offs should all be T handle type Using the proper size piping fittings and components build the gas supply line to the water heater NOTICE The gas supply line should be a minimum of 3 4 in 1 9 cm black steel pipe or other approved gas piping material Install a sediment trap at the lowest portion of the gas line The inlet gas pressure to the water heater must NOT exceed 10 5 in w c 2 6 kPa ...

Page 54: ...rvice technician Pressure Testing the Gas Supply System CAUTION If inlet gas pressure is out of allowable range 4 0 w c 1 0kPa 10 5 w c 2 6kPa for Natural Gas or 8 0 w c 2 0kPa 13 0 w c 3 2kPa for LP gas a gas pressure regulator must be installed to maintain the allowable inlet gas pressure The water heater and its manual gas shut off valve must be disconnected from the gas supply piping system wh...

Page 55: ... a ground terminal Keep any excess length of the power supply cord on the outside of the water heater If local codes require hard wiring see instructions for Hard Wiring the Electrical Connections below Hard Wiring the Electrical Connections Wiring should be performed by a qualified electrician in accordance with local codes The water heater requires a properly grounded 120 VAC 60 Hz power supply ...

Page 56: ...56 Electrical Electrical Wiring cont Wiring Diagram INSTALLATIONINSTRUCTIONS ...

Page 57: ...where it can come in contact with water Avoid installing the remote control in the following areas and or conditions area exposed to heat area exposed to steam area exposed to oil area exposed to direct sunlight areas near stored or used flammable products Place remote control out of children s reach The remote control should be installed in a convenient location e g kitchen laundry room utility r...

Page 58: ...the location of the remote control and the water heater Remove the remote control from the base plate Feed the remote control cable through the large center hole in the base plate Install the base plate to the wall using suitable screws and wall anchors NOTICE The tabs on the base plate should always point out Connect the remote control to the remote control cable Position the remote control on th...

Page 59: ...ct the remote control extension cables from the remote control to the remote control connection terminals NOTICE The remote control wire connection terminals are not polarity sensitive Firmly tighten the terminal screws by hand Secure the remote control extension cable on the hook located on the side of the remote control connection base Reinstall the remote control connection cover and secure wit...

Page 60: ... for such loss or injury resulting from the use of such unauthorized devices Installation Precautions Follow all installation instructions covered in this manual Check the inlet gas pressure to make sure it is within the range specified on the rating plate Make sure there is adequate air for combustion and ventilation as described on pages 38 39 or page 43 in this manual Maintain proper clearances...

Page 61: ...ength is observed Water supply has sufficient pressure Air has been purged from the water heater and the piping Water connections tight and free from leaks Water filter is clean and in place All piping has been assembled as described on pages 47 and 48 Water pipes are insulated and protected from freezing if necessary Pressure relief valve properly installed with discharge line running to open dra...

Page 62: ...be suitable for use with drinking water If this water heater is installed in an application intended to supply domestic hot water needs and hot water for space heating purposes do not connect the heater to an existing heating unit or components of a heating system that have previously been used with a nondrinking water system Toxic chemicals such as those used for boiler treatment may be present a...

Page 63: ...mpt to light the burner by hand 4 Turn the Gas Shutoff Valve located on the outside of the unit clockwise to the OFF position 5 Wait five 5 minutes to clear out any gas If you then smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 6 Turn the Gas Shutoff Valve located on the outside of the unit counterclockwise to the ON position 7 Turn...

Page 64: ...he front cover of this manual Turn the gas shut off valve counterclockwise to the ON position Turn on all electric power to the water heater The water heater burner will automatically light when there is a demand for hot water WARNING DO NOT attempt to light the burner by hand Lighting the burner by hand is an unsafe operating condition that can result in death personal injury property damage and ...

Page 65: ...C Turn on the remote control Turn off the gas and water to the water heater by closing the shut off valves Press the UP adjustment button repeatedly until 120 F 49 C shows in the LED display Hold the UP button until 120 on the display starts to blink NOTICE LED display only shows F Time Temperature Relationship in Scalds Water Time to Produce Temperature a Serious Burn 120 F 49 C More than 5 minut...

Page 66: ...ote control Turn off the gas and water to the water heater by closing the shut off valves Press the DOWN adjustment button repeatedly until 100 F 38 C or 85 F 29 C shows in the LED display Hold the DOWN button until the number on the display starts to blink While the number is blinking press the UP and DOWN adjustment buttons at the same time The number will stop blinking Press the UP or DOWN adju...

Page 67: ... 117 and USC2 117 Residential water heater temperatures can be adjusted down to 85 F 29 C when required To change the temperature settings down to 85 F 29 C Turn on the remote control Turn off the gas and water to the water heater by closing the shut off valves Press the DOWN adjustment button repeatedly until 100 F 38 C shows in the LED display NOTICE LED display only shows F Press the DOWN adjus...

Page 68: ... is above 6 560 ft 2 000 m and below 9 840 ft 3 000 m change the fourth switch to the ON position UP NOTICE DO NOT alter any other DIP switch settings The manifold pressure will be reduced accordingly Replace the front cover panel Turn on the gas and water to the water heater by opening the shut off valves Control Board Dip Switches 3 Dip switch adjustment 3 280 feet 1 000 m thru 6 560 feet 2 000 ...

Page 69: ... the rating plate 2 Specify the gas type natural or LP as marked on the rating plate 3 Parts description as shown below and number of parts desired Direct Vent Gas Components 11 9 10 7 8 2 5 1 4 3 6 15 8a 14 13 Ref Description 1 Control Board 2 Gas Valve Assembly 3 Burner Assembly 4 Igniter Coil 5 Blower Motor 6 Burner Manifold 7 Gas Inlet Connector 3 4 8 Water Control Valve Ref Description 8a Wat...

Page 70: ...as Valve Assembly 3 Burner Assembly 4 Igniter Coil 5 Blower Motor 6 Burner Manifold 7 Gas Inlet Connector 3 4 8 Water Control Valve 8a Water Bypass Valve 9 Water Inlet Connector 3 4 10 Inlet Water Filter 11 Hot Water Outlet Connector 3 4 13 Front Cover 14 Remote Control Terminal Block PARTSREPLACEMENT ...

Page 71: ...ponent parts and one 1 year for certain labor as described under the heading LABOR SHIPPING AND PROCESSING COST if the water heater is installed in a system in which the water is re circulated using a continuously operating pump Commercial any installation that is not a single family dwelling Five 5 years from the Effective Date for the heat exchanger five 5 years from the Effective Date for the c...

Page 72: ...s to have features not found in the defective water heater or the defective component part s you will be charged for the difference in price represented by those required features If you pay the price difference for those required features and or to upgrade the size and or other features available on a replacement new water heater you will also receive a complete new Limited Warranty with the full...

Reviews: