background image

1. Introduction

The Tannoy T12 and i12 professional loudspeakers have been designed for a wide variety of
sound reinforcement applications requiring extended frequency response from a compact system,
capable of delivering high sound pressure levels with extremely low distortion, resulting in
outstanding clarity, definition and detail.

The T12 and i12 comprises one 12 inch Dual Concentric driver in which the low frequency (LF)
and high frequency (HF) sources are coincidentally aligned to a point source, resulting in a smooth
uniform frequency response over a wide area of coverage either as a portable stand alone system
or in a multi-cabinet array. The sophisticated CAD designed waveguide combines 60 degree
conical dispersion and excellent acoustic impedance characteristics. As the system is a point
source, clusters and arrays have minimal lobing. These features are inherent and achieved
without the use of any electronic signal processing.

The T12 features a recessed carrying handle, stand mount  and a rugged, multiple-ply hardwood
cabinet with structural integrity further enhanced by internal steel braces which double as the flying
points accepting M8 eyebolts  strategically placed to distribute the weight of the enclosure evenly.
The T12 can also be used as a low profile stage monitor. Its conical coverage pattern gives the
performer greater freedom of movement than allowed by conventional horn loaded designs.

While delivering the same performance as the T12 and utilising the same transducer and high
power, low-loss crossover components the i12 is designed for fixed installations. Featuring the
same flying system as the T12 the i12 is constructed from medium density fibreboard (MDF), for a
high level of acoustic damping.

For applications requiring extended low frequency enhancement, a range of Tannoy sub-bass
systems are available and can be used in conjunction with the T12 and i12.

2. 

 Unpacking

Every Tannoy T12 and i12 product is carefully inspected before packing. After unpacking your
loudspeaker, please inspect for any exterior physical damage, and save the carton and any
relevant packaging materials in case the loud speaker again requires packing and shipping. In the
event that damage has been sustained in transit notify your dealer immediately.

3. 

 Connectors/Cabling

T12 and i12 are fitted with 4-pole Speakon

 connectors. Speakon has the following advantages

over EP and XLR type connectors: All termination’s are solderless, this makes life easier at the
time of installation or when field servicing is required. Contacts will accept 6 sq. mm wire with an
outside diameter of up to 15mm and a current rating of 30 Amps. The pins of the 2 Speakon
sockets identified input/output on the rear of the input panel are paralleled within the enclosure.
Tannoy have adopted the following wiring standard for the T12 and i12 products :-

Pin 1+ is Positive
Pin 1-  is Negative

Summary of Contents for i12

Page 1: ...T12 i12 USER MANUAL ...

Page 2: ......

Page 3: ...cking 5 Amplification Power Handling 6 Crossovers 7 Equalisation 8 Dimensions 9 Rigging 10 Performance Data 11 Technical Specifications 12 T12 i12 Recommended Service Parts Accessories 13 Warranty 14 Wall Mounting Bracket Assembly Instructions 15 Declaration of Conformity ...

Page 4: ...rmer greater freedom of movement than allowed by conventional horn loaded designs While delivering the same performance as the T12 and utilising the same transducer and high power low loss crossover components the i12 is designed for fixed installations Featuring the same flying system as the T12 the i12 is constructed from medium density fibreboard MDF for a high level of acoustic damping For app...

Page 5: ... 6 0 0 69 0 43 0 29 8 6 5 4 3 6 17 0 11 0 7 2 100 2 5 4 0 6 0 1 38 0 86 0 58 17 0 11 0 7 2 35 0 22 0 14 0 4 Polarity Checking It is most important to check the polarity of the wiring before the speaker system is flown A simple method of doing this without a pulse based polarity checker for LF units is as follows Connect two wires to the ve and ve terminals of a PP3 battery Apply the wire which is ...

Page 6: ...ortant when using different manufacturers amplifiers in a single installation that the have very closely matched gains the variation should be less than 0 5dB This precaution is important to the overall system balance when only a single active crossover is being used with multiple cabinets it is therefore recommended that the same amplifiers are used throughout 6 Crossovers The T12 and i12 are sup...

Page 7: ...7 Dimensions ...

Page 8: ......

Page 9: ...8 Performance Data ...

Page 10: ......

Page 11: ......

Page 12: ...rossover Point Passive 1 5 kHz 2 nd order high pass 2 nd order low pass Halogen HF protection Enclosure 38 7 litre vented 15mm birch plywood T12 MDF i12 Finish Textured black grey paint Protective Grille Perforated steel black with 58 free air flow Connectors 2 x Speakon NL4MPR IN OUT Fittings T12 1 x Recessed carrying handle T12 1 x 35mm pole mounting socket T12 i12 8 x M8 flying inserts 1x M8 pu...

Page 13: ...der warranty should only be carried out by a Tannoy Professional dealer or service agent This warranty in no way affects your statutory rights For further information please contact your dealer or distributor in your country If you cannot locate your distributor please contact Customer Services Tannoy Ltd at the address given below Customer Services Tannoy Ltd Rosehall Industrial Estate Coatbridge...

Page 14: ...sing the two cap head bolts which are included along with the bracket hardware remembering to use the washers and locking washers which are also provided Assemble the bracket as shown on the diagram below It is imperative that the bracket is fixed soundly to the wall Be sure to use the correct fixings e g Rawbolt Rawplug according to the wall type Portrait mounting Using a hacksaw cut along the in...

Page 15: ...d such that electromagnetic disturbances generated do not exceed levels allowing radio and telecommunications equipment and other apparatus to operate as intended and the apparatus has an adequate level of intrinsic immunity to electromagnetic disturbance to enable operation as specified and intended Details of the Apparatus Tannoy Contractor Loudspeaker Model Number T12 i12 Associated Technical F...

Page 16: ... 0 1236 420199 Fax 44 0 1236 428230 Internet http www tannoy com Tannoy North America Inc 335 Gage Avenue Suite 1 Kitchener Ontario CANADA N2M 5E1 Telephone 519 745 1158 Fax 519 745 2364 Tannoy Nederland BV Anthonetta Kuijlstraat 19 3066 GS Rotterdam THE NETHERLANDS Telephone 010 2860554 Fax 010 2860431 Issue 3 Part No 6481 0266 GH 14th April 1997 ...

Reviews: