background image

5

4.3. Controls

The input level volume control is located on the front of the unit. This has been se t to
maximum when shipped. To adjust the level, simply remove the badge and adjust the
gain using a screw driver.

5. Operation close to TV screens and video monitors

As the i5 MP contains a powerful magnet, avoid placing the unit closer than 6" to a
TV s creen or video monitor in order to avoid any picture distortion.

6. Equalisation

The i5 MP is designed to need no equalisation or correction to overcome system
limitations. As a result, it will only need equalisation to compensate for difficult
acoustic environments.

Excess equalisation can reduce system headroom, and introduce phase distortion
resulting in greater problems than it cures. If equalisation is required then it should be
applied gently and smoothly. Violent equalisation will be detrimental to the overall
sound quality. If the loudspeakers were being used consistently at high levels it would
be beneficial to introduce a high- pass filter at 70Hz to protect the loudspeaker from
any unnecessary subsonic frequencies.

7. Dimensions

100-120V / 220-240V~ 50-60Hz 45W

110/120V

230V

220/240V

INPUT

2

1

3

+

G

-

T1AL 125V

T500mAL 250V

FUSE

ON

OFF

224mm

8

7

/

8

"

163mm

6

3

/

8

"

153mm

6

1

/

8

"

Summary of Contents for i5 MP

Page 1: ...i5 MP USER MANUAL ...

Page 2: ...onnectors Cabling 4 4 2 Powering 4 4 3 Controls 5 5 Operation close to TV screens and video monitors 5 6 Equalisation 5 7 Dimensions 5 8 Hardware 6 9 Performance Data 7 10 Technical Specifications 9 11 IMPORTANT SAFETY INFORMATION 10 12 i5 MP Service Parts Accessories 11 13 Warranty 11 ...

Page 3: ...re that has been optimally tuned to achieve maximum bass response and tonal balance For applications requiring extended low frequency enhancement a range of Tannoy sub bass systems are available and can be used in conjunction with the i5 MP 2 Unpacking Every Tannoy i5 MP is carefully tested and inspected before packing After unpacking please inspect your i5 MP for any damage sustained during trans...

Page 4: ...ctor shielded cable microphone cable and wire the European pluggable type connector as shown in the chart below Pin 1 Ground Screen Pin 2 Positive ve Red Pin 3 Negative ve Blue 4 2 Powering Before connecting th e i5 MP to a mains inlet socket ensure all other connections are correctly made The i5 MP may be supplied with an IEC mains cable Connect this cable into the IEC mains socket on the back of...

Page 5: ...ations As a result it will only need equalisation to compensate for difficult acoustic environments Excess equalisation can reduce system headroom and introduce phase distortion resulting in greater problems than it cures If equalisation is required then it should be applied gently and smoothly Violent equalisation will be detrimental to the overall sound quality If the loudspeakers were being use...

Page 6: ...n demonstrated in Figures 8b 8c Figure 8a Figure 8b Figure 8c NOTE The installation of this product must be carried out in conformity with local building codes and standards If necessary consult your local safety standards officer before installing any product Alternatively check any laws or bylaws Tannoy will not be held responsible for any damages caused by the improper installation of any brack...

Page 7: ...7 9 Performance Data Frequency Response Off Axis Frequency Response ...

Page 8: ...8 Polar Plots 1 Octave Band Pink Noise ...

Page 9: ...lack or White Connectors Balanced Phoenix style 3 terminal in unbalanced RCA in Fittings 2 x yoke fixing points 1 x female gimble plate Dimensions 223 5 H 162 6 W 153 0 D mm 8 81 H 6 41 W 6 03 D Weight 2 9kg 6lbs 5oz Accessories MB5Y and MB5B mounting brackets Shipping Dimensions 302 x 168 x 168mm 12 7 8 x 6 3 8 x 6 3 8 Shipping Weight 3 1kg 6lbs 15oz NOTES 1 Average over stated bandwidth Measure ...

Page 10: ...t having a moulded plug at one end and a moulded mains plug appropriate to the country of use at the other end Where the moulded plug is fitted with a mains fuse always replace with the same type and rating If the fitted plug is unsuitable for your type of outlet sockets it should be cut off and disposed of safely in case it is inserted into a live socket elsewhere The wires in the mains cable are...

Page 11: ...ontact your dealer or distributor in your country If you cannot locate your distributor please contact Customer Services Tannoy Ltd at the address given below Customer Services Professional Division Tannoy Ltd Coatbridge Scotland ML5 4TF Telephone 01236 420199 National 44 1236 420199 International Fax 01236 428230 National 44 1236 428230 International E Mail service tannoy co uk DO NOT SHIP ANY PR...

Page 12: ...site www tannoy com Tannoy North America Inc 335 Gage Avenue Suite 1 Kitchener Ontario Canada N2M 5E1 Tel 519 745 1158 Fax 519 745 2364 e mail inquiries tannoyna com Website www tannoy com Tannoy Nederland b v Anthonetta Kuijlstraat 19 3066 GS Rotterdam Tel 010 286 0554 Fax 010 286 0431 e mail info tannoy nl Website www tannoy nl M L 2 nd October 2003 ...