background image

 

MODEL DISTANCE 

POSITION 

SENSITIVITY XOVER 

FREQ 

 

 

 

 

 

6 1/2" Dual Concentrics: 

 

 

 

 

D100, D300, System 6 

45mm 

89dB 

18kHz 

 

 

 

 

 

8" Dual Concentrics: 

 

 

 

 

Esher SL25, NFM 8, DTM 8,  

57mm 

90.5dB 

18kHz 

System 8, D500, D750 

 

 

 

 

Greenwich 87mm 

90.5dB 

18kHz 

 

 

 

 

 

10" Dual Concentrics: 

 

 

 

 

LSU/HF/3LZL (Monitor Red)*, 

78mm 

90.5dB 

14kHz 

LSU/HF/3LZG (Monitor Gold)*,  

 

 

 

 

HPD295*, [*General setting, from 

 

 

 

 

baffle front], Darking SL35, Windsor, 

 

 

 

 

Ascot T125, Chester T165,  

 

 

 

 

Dorset T185, Mayfair T225 

 

 

 

 

Buckingham 78mm 

92.0dB 

14kHz 

System 10 

78mm 

92.0dB 

16kHz 

D700 78mm 

92.0dB 

18kHz 

3LZ, Chevening, Eaton, Caernarvon, 

105mm 

90.5dB 

14kHz 

SRM10B  

 

 

 

Stirling/HW 105mm 

92.0dB 

14kHz 

Stirling/TW/TWW, Turnberry HE 

105mm 

92.0dB 

16kHz 

Stirling HE 

105mm 

90.5dB 

18kHz 

 

 

 

 

 

12" Dual Concentrics: 

 

 

 

 

LSU/HF/12L (Monitor Silver)*, 

87mm 

92.0dB 

14kHz 

LSU/HF/12L (Monitor Red)*, 

 

 

 

 

LSU/HF/128G (Monitor Gold)*, 

 

 

 

 

*[General setting from baffle front]. 

 

 

 

 

HPD315* 87mm 

90.5dB 

14kHz 

*[General setting from baffle front]. 

 

 

 

 

System 12, D900 

87mm 

93.5dB 

16kHz 

Canterbury (corner), Lansdowne, 

120mm 

92.0dB 

14kHz 

Chatsworth, Lancaster 12, DC4000, 

 

 

 

 

Edinburgh/HW, Canterbury 12, 

 

 

 

 

SRM12X, LGM (Little Gold Monitor) 

 

 

 

 

Mansfield, Devon, Cheviot,  

120mm 

90.5dB 

14kHz 

Bradley SL65, Chertsey SL45, 

 

 

 

 

Balmoral  

 

 

 

Edinburgh/HW, Canterbury 12, 

 

 

 

 

Edinburgh/TW/TWW/HE 120mm 

93.5dB 

16kHz 

 

 

 

 

 

15" Dual Concentrics: 

 

 

 

 

Monitor Black*, HPD383*, Albury 

100mm 

92.0dB 

14kHz 

LSU/HF/15L (Monitor Silver)*, 

100mm 

93.5dB 

14kHz 

LSU/HF/15L (Monitor Red)*, 

 

 

 

 

LSU/HF/158G (Monitor Gold)* 

 

 

 

 

*[General setting from baffle front]. 

 

 

 

 

System 15, System 215 

100mm 

95.0dB 

16kHz 

Amesbury, Berkeley, Arden, 

130mm 

92.0dB 

14kHz 

Arundel, Balmoral, M3000 

 

 

 

 

York, Lancaster 15, SRM15X, FSM, 

130mm 

93.5dB 

14kHz 

M1000, SGM1000, SGM3000 

 

 

 

 

Dreadnought 130mm 

95.0dB 

14kHz 

GRF (horn), Canterbury 15 (incl. HE) 

155mm 

95.0dB 

14kHz 

GRFM/HW 195mm 

95.0dB 

14kHz 

GRFM/TW/TWW/HE,  

195mm 

95.0dB 

14kHz 

Westminster TW 

 

 

 

 

RHR 247mm 

95.0dB 

14kHz 

Westminster Royal/HE 

317mm 

95.0dB 

14kHz 

Autograph 405mm 

95dB 

14kHz 

 

 

TABLE 1 

 

 

Summary of Contents for Prestige SuperTweeter ST200

Page 1: ...ST 200 Prestige SuperTweeter Please take time to carefully read this manual before installing and using your Tannoy SuperTweeter...

Page 2: ...h any of our earlier classic designs be they previous Prestige models HPD Monitor Gold or Monitor Silver for example Adjustments are provided for crossover frequency and level to enable accurate match...

Page 3: ...trol turned fully down before beginning Typical wiring configurations are shown in Fig 1 A Typical single wired installation The SuperTweeter is simply connected across your speaker terminals On optio...

Page 4: ...inly for large horn loaded enclosures such as Westminster Westminster Royal Autograph and GRF Please check the length required for your speakers should you require cable TO AMPLIFIER EARTH OPTIONAL HF...

Page 5: ...models is included Firstly with reference to Fig 2 position the felt mat centrally on the loudspeaker enclosure then the alignment gauge such that it is flush with the front of the cabinet Use of the...

Page 6: ...Hz MADE IN GRE AT BRITAIN CROSSOVER FREQUENCY 90 5dB 89dB 93 5dB 92dB SENSITIVITY 95dB PRESTIGE ALIGNMENT GAUGE PRESTIGE SUPERTWEETER EDGE OF CABINET POSITION ON FRONT A ST 200 B A B PART No 6481 0325...

Page 7: ...PD315 87mm D 90 5dB 14kHz General setting from baffle front System 12 D900 87mm D 93 5dB 16kHz Canterbury corner Lansdowne 120mm G 92 0dB 14kHz Chatsworth Lancaster 12 DC4000 Edinburgh HW Canterbury 1...

Page 8: ...ted After double checking the wiring you are now ready to switch your amplifier on Select some music you are familiar with and gently advance the volume control to normal listening level 95dB 93 5dB 9...

Page 9: ...B steps The CROSSOVER FREQUENCY control offers 3 positions for the SuperTweeter energy to be rolled in Fig 4 The position of the SuperTweeter has been determined in Table 1 to correspond to the acoust...

Page 10: ...ible use with larger amplifiers on wide dynamic range material Take care with any amplifier irrespective of power output to avoid abnormal conditions such as switch on surges or output overload clippi...

Page 11: ...titanium dome 24 Karat vapour deposited gold finish with neodymium magnet system CROSSOVER Crossover type 3rd order compensated high pass Crossover frequency 14 16 or 18kHz adjustable Level adjustment...

Page 12: ...member of the TGI PLC group of companies Tannoy Limited Coatbridge ML5 4TF Scotland Telephone 44 1236 420199 Fax 44 1236 428230 Email salesdesk tannoy com Internet http www tannoy com Part No 6481 032...

Page 13: ......

Reviews: