background image

Crossovers & Amplifier Output Settings

VSX Series subwoofers do not incorporate internal high-pass or 
low-pass filters for restricting input signal bandwidth. Therefore, it is 
recommended that the amplifier output connected to the VSX subwoofer 
should be band-limited by using either an external active crossover in 
front of the amplifier or a dedicated subwoofer output filter incorporated 
in the amplifier. Applying a full range output signal to the VSX Series 
subwoofer input will reduce overall efficiency and could risk damage to 
the unit at higher operating levels.

Most generic subwoofer settings will be adequate for driver 
protection and minimally satisfactory performance.  However, for 
optimum performance is it recommended that the crossover be set 
for the requirements of the specific VSX model.  The recommended 
values for high-pass filter (HPF), low-pass filter (LPF) and PEQ 
(parametric equalizer) are given in the full VSX Series Operation Manual.

Rigging and Safety Procedures

Tannoy Professional loudspeakers should be installed only by fully 
qualified installers using dedicated Tannoy hardware, in accordance 
with all the required safety codes and standards that are applied at 
the place of installation. 

WARNING: As the legal requirements for flying / suspending / hanging / 
rigging loudspeakers change from country to country, please consult 
your local safety standards office before installing any product. We 
also recommend that you thoroughly check any laws and bylaws 
prior to installation. 

For more detailed information on rigging hardware and safety 
procedures, please consult the full VSX Series Operation Manual, 
available at www.tannoy.com/pro.

Unpacking

Each Tannoy VSX Series subwoofer is carefully tested and inspected 
prior to shipment. After unpacking, please check for any exterior 
physical damage, and save the carton and any relevant packaging 
materials in case the unit again requires packing and shipping. In the 
event that damage has been sustained in transit, notify your dealer 
and the shipping carrier immediately. 

Cables and Connectors

Inputs are provided on both speakON® NL4 connectors and barrier 
strip terminals. Two inputs of each type are provided, with each set 
wired in parallel, to enable connection of an additional subwoofer to 
the same amplifier output.  Refer to the full VSX Operation Manual 
for guidelines on maintaining proper combined system impedance 
when connecting more than one unit by making parallel and series / 
parallel connections.

The speakON connectors will accept wire up to 4 mm sq CSA 
(AWG 12) with an outside diameter of up to 15 mm and a current 
rating of 30 A. The pins of the two speakON sockets identified as 
input / output on the rear of the input panel are paralleled within the 
enclosure. Tannoy have adopted the conventional wiring standard 
for the VSX Series product: pin 1+ is positive pin 1- is negative. 
For a worldwide list of Neutrik® distributors see www.neutrik.com.