I n t r o d u c t i o n
The Monaco heater produces radiant heat like the sun, warming people and objects rather than the air in between. It is
mounted on an adjustable bracket that allows the heat to be directed exactly where it is required. Its attractive, lightweight
design means that it is effective yet unobtrusive. The Monaco is designed for indoor and outdoor use so is therefore
weatherproof.
Please read the following instructions carefully before use. The safety of this heater is guaranteed only by its
correct usage in accordance with these instructions, therefore it is recommended that they are retained for future
reference.
S p e c i f i c a t i o n
T a b l e 1 . U K a n d E u r o p e a n H e a t e r s
Voltage Total Current Min. height
Min. dist.
Min. dist.
Dimensions
Weight
Ingress
Model
(V)
Power
(A)
from floor from ceiling from side
W × H × D
(kg)
Protection
(W)
(m)
(m)
wall (m)
(mm)
(IP)
SOR 215IP
*-M
230
1500
6.5
2.0
0.3
1.0
402 x 227 x 323
3.4
IP55
Use MCB Type 3 or C.
4
I n s t a l l a t i o n
The Monaco heater is fitted with a supply cord and a moulded plug, therefore it is unnecessary to open the terminal box
in order to carry out normal installation of this product and should not be interfered with.
We recommend using a RCD where applicable.
Please observe the minimum safe distance between the heater body and any inflammable surfaces.
If the supply cord becomes damaged, it must be replaced by the manufacturer, its service agent or a similar qualified
person in order to avoid a hazard.
When the electrical connection is outside, it is recommended that a waterproof socket is used for the connection.
Otherwise, the plug should be connected to a socket indoors.
If in any doubt, please contact a suitably qualified electrician.
M o u n t i n g
The Monaco heater can be wall/surface mounted in a horizontal (Fig. A)
or angled manner (Fig. B) or hung from a ceiling (Fig. D) from chains (not
supplied).
When wall/surface mounting the Monaco heater in a horizontal manner,
do not position the heater at an angle more than 90° and less than 45° as
shown in Fig. A.
When surface mounting the Monaco heater in an angled manner, ensure
the mounting surface is angled so the heater projects downwards - see
Fig. C. Do not position the heater at an angle more than 45° and less than
30° to the horizontal as shown. Position the heater so the cord is exiting
the terminal box pointing down.
When ceiling hanging the Monaco heater, ensure the minimum distance
from the ceiling is adhered to as shown in Fig. D.
continued...
HORIZONTAL MOUNTING
Fig. A
Always allow the heater to cool before attempting to
reposition/move. Never attempt to move the heater while it is
switched on!
Observe the minimum safe distance between the heater body
and inflammable surfaces and objects when mounting.
Please refer to Table 1 for the recommended positioning of
the heater with regards to minimum distances. Do not install
the heater in a corner!
Do not mount the heater on plastic soffits and fascia boards
and ensure the mounting surface will suitably withstand the
radiant heat from the heater body.
Keep out of the reach of children.
1. When wall mounting, securely fasten the L-shaped wall
bracket to the mounting surface using both of the fixing holes in
the short part of the bracket. Refer to Table 1 for recommended
positioning of the heater. Please note: wall fixings are not
supplied. They should be selected to substantially support the
weight of the installation. If in doubt contact a professional for
advice!
2. The heater can be fixed to the wall bracket securely with the
nuts and bolts provided as shown in Fig. C.
3. The heater should be mounted with the terminal box at the
bottom of the heater.
4. When wall mounting, fix in the required angular position by
tightening the fixing bolt on the brackets at the rear of the heater
as pointed out in Fig. C.
5. Secure the supply cable so it is not resting on the body or
obstructing the air-vents.
Always isolate the heater from the mains supply when
adjusting the position.
ANGLED MOUNTING
5
Fig. C
Fig. B
Fig. D
AN
GLE
D M
OU
NT
ING
SU
RF
AC
E
1. Please refer to Table 1 for recommended positioning of the
heater. When hanging from a ceiling two chains of equal
length and gauge are required and should be selected with
fixings that are adequate to hold the weight of the heater. If in
doubt contact a professional for advice!
2. Fix the heater assembly to the chains via the holes in the tabs
on the end castings as shown in Fig. D. and ensure the heater
faces directly down when hanging.
3. Secure the supply cable so it is not resting on the body or
obstructing the air-vents.
Always isolate the heater from the mains supply when
adjusting the position.
C e i l i n g H a n g i n g