W a l l   M o u n t i n g  -  T h r e e   I n d i v i d u a l   H e a t e r s   J o i n e d  

 

When three Sorrento IP heaters are joined together they can be mounted in a horizontal or angled manner as the emitter is a universal burning 
type. 

 

When wall mounting three Sorrento IP heaters joined together in a horizontal manner, do not position the heater at an angle more than 80° and 
less than 60° as shown in Fig. L. 

 

When vertically mounting three Sorrento IP heaters joined together, ensure the mounting surface is angled so the heater projects downwards - see 
Fig. C on Page. 3. Do not position the heater at an angle more than 45° and less than 30° to the horizontal as shown. Position the heater so the 
cords are exiting the terminal box pointing down. 

 

Always  allow  the  heater  to  cool  before  attempting  to  reposition/move.  Never  attempt  to  move  the 
heater while it is switched on! 

 

Observe the minimum safe distance between the heater body and inflammable surfaces and      
objects when mounting. 

 

Please  refer  to  Table  1  for  the  recommended  positioning  of  the  heater  with  regards  to  minimum 
distances. Do not install the heater in a corner! 

 

Keep out of the reach of children. 

 
1.    Securely fasten the L-shaped wall brackets to the mounting surface using both of the fixing holes in 

the  short  part  of  the  bracket  (see  Fig.  M  for  mounting  hole  centres).  Please  refer  to  Table  1  for  
recommended positioning of the heater. Please note. wall fixings are not supplied. They should be 
selected to substantially support the weight of the installation. If in doubt contact a professional for 
advice! 

 
2.    The heater assembly should be mounted with the terminal boxes at the bottom of the heaters. 
 
3. Fix  the  heater  assembly  to  the  brackets  via  the  bolt  threads  on  the  middle  heater.  A  serrated 

washer should be placed on the threads first and the wall brackets should prise apart in order to fit 
the threads in place. 

 
4. Place a washer and a nut on the thread on the outside of the wall brackets – both sides. 
 
5. Fully tighten the nut and bolts with the heater set at the desired angle. 
 
6.    Secure  the  supply  cable  so  it  is  not  resting  on  the  body  or  obstructing  the  air-

vents. 

 

Always isolate the heater from the mains supply when adjusting the angular 
position.

 

C e i l i n g   H a n g i n g - T h r e e   I n d i v i d u a l   H e a t e r s   J o i n e d  

 

When three Sorrento IP heaters are joined they can be hung from a ceiling from chains. 

 

Always allow the heater to cool before attempting to reposition/move. Never attempt to move the heater while it is switched on! 

 

Observe the minimum safe distance between the heater body and inflammable surfaces and objects when mounting. 

 

Please refer to Table 1 for the recommended positioning of the heater with regards to minimum distances. Do not install the heater in a corner! 

 

Keep out of the reach of children. 

 
1.    Please  refer  to  Table  1  for  recommended  positioning  of  the  heater.  When     

hanging  from  a  ceiling  four  chains  of  equal  length  and  gauge  are  required  and 
should be selected with fixings that are more than adequate to hold the weight of 
the heater. If in doubt contact a professional for advice! 

 
2. Fix  the  heater  assembly  to  the  chains  via  the  hole  in  the  centre  of  the  joining 

bars  as  shown  in  Fig.  N.  and  ensure  the  heater  faces  directly  down  when    
hanging. 

 
3.    Secure  the  supply  cable  so  it  is  not  resting  on  the  body  or  obstructing  the        

air-vents. 

 

Always isolate the heater from the mains supply when adjusting the position.

 

Fig. N 

Fig. M 

DRILLING HOLE TEMPLATE DIMENSIONS FOR 

WALL MOUNTED BRACKETS - 3 × HEATERS 

Fig. L 

M o u n t i n g - I n d i v i d u a l   U n i t   (Wall Mounting or Chain Hanging) 

 

The Sorrento IP heater can be wall mounted in a horizontal (Fig. A) or angled manner (Fig. C) or hung 
from a ceiling (Fig. B) from chains (not supplied). 

 

When wall mounting the Sorrento IP heater in a horizontal manner, do not position the heater at an angle 
more than 90° and less than 30° as shown in Fig. A. 

 

When mounting the Sorrento IP heater in an angled manner, ensure the mounting surface is angled so 
the  heater  projects  downwards  - see  Fig.  C.  Do  not  position  the  heater  at  an  angle more  than  45° and 
less  than  30°  to  the  horizontal  as  shown.  Position  the  heater  so  the  cord  is  exiting  the  terminal  box   
pointing down. 

 

When ceiling hanging the Sorrento IP heater, ensure the minimum distance from the ceiling is adhered to 
as shown in Fig. B. 

 

Always allow the heater to cool before attempting to reposition/move. Never attempt to move the heater 
while it is switched on! 

 

Observe  the  minimum  safe  distance  between  the  heater  body  and  inflammable  surfaces  and  objects 
when mounting. 

 

Please  refer  to  Table  1  for  the  recommended  positioning  of  the  heater  with  regards  to  minimum          
distances. Do not install the heater in a corner! 

 

Keep out of the reach of children. 

 
1. When wall mounting, securely fasten the L-shaped wall brackets to the mounting surface using both of 

the fixing holes in the short part of the bracket (see Fig. E on the next page for mounting hole centres). 
Refer to Table 1 for recommended positioning of the heater. Please note. wall fixings are not supplied. 
They  should  be  selected  to  substantially  support  the  weight  of  the  installation.  If  in  doubt  contact  a    
professional  for  advice! When  hanging  from  a  ceiling  two  equal  length  and  gauge  chains  are  required 
and should be selected with fixings that are more than adequate to hold the weight of the heater. Again, 
if in doubt  contact a professional for advice! 

 
2. The  heater  should  be  mounted  with  the  terminal  box  at  the  bottom  of  the  heater  when  being  wall 

mounted. 

 
3.   When wall mounting, fix in the required angular position by tightening the fixing bolts on the brackets at 

the rear of the heater as shown in Fig. D. The heater should face directly down when hanging. Ensure 
that  the  serrated  washer  is  placed  between  the  surface  of  the  wall  bracket  and  the  bracket  on  the 
heater. 

 
4.   Secure the supply cable so it is not resting on the body or obstructing the air-vents. 
 

Always isolate the heater from the mains supply when adjusting the position.

 

Fig. A 

Fig. D 

Fig. C 

Fig. B 

When the electrical connection is outside, it is recommended that a waterproof socket 
is  used  for  the  connection/terminal.  Otherwise,  the  plug  should  be  connected  to  a 
socket indoors. 

If in any doubt, please contact a suitably qualified electrician. 

 
1.  Unscrew  the  terminal  box  cover  at  the  back  of  the  heater  and  feed  the  supply  cable 
through the compression gland ensuring the rubber seal is on the cable. 
 
2.  Use  a  minimum  of  1.0mm

2

  H05RN-F  supply  cable  with  2  poles  and  earth  and  sleeve 

with  silicon  glass  fibre  braided  (250°C)  Sleeving.  The  live  and  neutral    wires  must  be    
connected to the terminal block. See Fig 1. 

3. The green/yellow wire should be connected to the clamp marked with the earth symbol using a suitable 
wire terminal. Fit cord grip and terminal box saddle once wired. 
 
4. Tighten the barrel nut of the compression gland so that the rubber seal grips the cable (Fig 2). 
 
5. To prevent water ingress, ensure that the cover is secured well by hand tightening all for screws evenly. 

 

AN

G

LE

D

 M

O

U

N

TIN

G

 S

U

R

FA

C

E

 

Fig. 1 

Fig. 2 

Summary of Contents for SOR 210IP

Page 1: ...ig U from the side reflector and lift it up away from the heater to remove it Repeat at opposite end to remove other side reflector 8 The emitter the wires should be pulled out of the side slots and the emitter can be lifted up completely Fig V The wires should be gently pulled so they come out from behind the reflector 9 The emitter should now be removed from the heater as shown in Fig X 10 Refit...

Page 2: ...3 8 7 2 5 0 5 1 0 402 460 402 6 8 IP24 2 SOR 215IP 230 2 1500 3000 6 5 13 0 3 0 0 5 1 0 402 460 402 6 8 IP24 2 SOR 220IP 230 2 2000 4000 8 7 17 4 3 5 0 5 1 0 402 460 402 6 8 IP24 3 SOR 210IP 230 3 1000 3000 4 3 13 0 3 0 0 5 1 0 402 693 402 10 2 IP24 3 SOR 215IP 230 3 1500 4500 6 5 19 6 3 5 0 5 1 0 402 693 402 10 2 IP24 3 SOR 220IP 230 3 2000 6000 8 7 26 1 4 5 0 5 1 0 402 693 402 10 2 IP24 I n s t ...

Page 3: ... Fig M 6 DRILLING HOLE TEMPLATE DIMENSIONS FOR WALL MOUNTED BRACKETS 3 HEATERS Fig L M o u n t i n g I n d i v i d u a l U n i t Wall Mounting or Chain Hanging The Sorrento IP heater can be wall mounted in a horizontal Fig A or angled manner Fig C or hung from a ceiling Fig B from chains not supplied When wall mounting the Sorrento IP heater in a horizontal manner do not position the heater at an ...

Page 4: ...out of the reach of children Fig J DRILLING HOLE TEMPLATE DIMENSIONS FOR WALL MOUNTED BRACKETS 2 HEATERS 4 When two Sorrento IP heaters are joined they can be hung from a ceiling from chains Always allow the heater to cool before attempting to reposition move Never attempt to move the heater while it is switched on Observe the minimum safe distance between the heater body and inflammable surfaces ...

Reviews: