background image

A s s e m b l i n g   -   T w o   S i n g l e   H e a t e r s   J o i n e d

 

 
1.

Take the first heater and place it face down on a flat surface. 

 
2.

Take the second heater and place it face down and positioned parallel to the first heater. 

 
3.

Push the M8 bolts (used to hold the wall brackets through the hole in the brackets on the rear heaters and slide a shake-proof washer on all 
the threads from the protruding side. 

 
4.

Slide the joining bars on each bolt and fit a washer and nut – do not fully tighten at this point. 

 
5.

Ensure the second heater is still parallel to the first and sitting flat. 

 
6.

Slide the joining bars on each protruding bolt of the other heater to connect them together and fit the washers and nuts. 

 
7.           Again, ensuring the heaters remain flat, fully tighten all four nuts to secure the joining bars in place. 

W a l l   M o u n t i n g - T w o   S i n g l e   H e a t e r s   J o i n e d  

 

When two Sorrento IP heaters are joined together they can be mounted in a horizontal or vertical 
manner as the emitter is a universal burning type. 

 

When wall mounting two Sorrento IP heaters joined together in a horizontal manner, do not position 
the heater at an angle more than 45° and less than 10° as shown in Fig. F. 

 

When vertically mounting two Sorrento IP heaters joined together, ensure the mounting surface is 
angled so the heater projects downwards - see Fig. C on Page. 3. Do not position the heater at an 
angle more than 45° and less than 30° to the horizontal as shown. Position the heater so the cords 
are exiting the terminal box pointing down. 

 

Always allow the heater to cool before attempting to reposition/move. Never attempt to move the 
heater while it is switched on! 

 

Observe  the  minimum  safe  distance  between  the  heater  body  and  inflammable  surfaces  and   
objects when mounting. 

 

Please  refer  to  Table  1  for  the  recommended  positioning  of the  heater  with  regards  to        mini-
mum distances. Do not install the heater in a corner! 

 

Keep out of the reach of children. 

 
1.           Securely  fasten  the  L-shaped  wall  brackets  to  the  mounting  surface  using  both  of  the  fixing 
              holes  in  the  short  part  of  the  bracket  (see  Fig.  H  for  mounting  hole  centres).  Please  refer  to 
              Table  1  for  recommended  positioning  of  the  heater.  Please  note.  wall  fixings  are  not       
              supplied.  They  should  be  selected  to  substantially  support  the  weight  of  the  installation.  If  in 
              doubt contact a professional for advice! 
 
2.

Fix the heater assembly to the brackets via the hole in the centre of the joining bar. The joining 
bars should slide inside the gap of the two wall brackets. 

 
3.

Place  a  bolt  and  washer  in  the  hole  of  the  wall  bracket  and  put  a  serrated  washer  on  the    
opposite side between the bracket and joining bar. Repeat on opposite side. 

 
4.

Fit  the  heater  assembly  to  the  brackets  and  place  a  washer  and  nut  on  the  bolts  protruding 
through the joining bars. 

 
5.

Fully tighten the nut and bolts with the heater set at the desired angle 

              (Fig. G). 
 
6.

Secure the supply cable so it is not resting on the body or obstructing the 

              air-vents. 
 

              Always isolate the heater from the mains supply when adjusting the 
              angular position.

 

Fig. F 

Fig. G 

Fig. H 

2.

The heater should be mounted with the terminal box at the bottom of the heater when being wall mounted. 

 
3.          When wall mounting, fix in the required angular position by tightening the fixing bolts on  the brackets at the rear  of  the  heater  as  shown  in 
             Fig.  D.  The  heater  should  face  directly  down  when  hanging.  Ensure  that  the  serrated  washer  is  placed  between  the  surface  of  the  wall 
             bracket and the bracket on the heater. 
 
4.          Secure the supply cable so it is not resting on the body or obstructing the air-vents. 
 

Always isolate the heater from the mains supply when adjusting the position.

 

C e i l i n g   H a n g i n g  - T w o   S i n g l e   H e a t e r s   J o i n e d  

 

 When two Sorrento IP heaters are joined they can be hung from a ceiling from chains. 

 

Always allow the heater to cool before attempting to reposition/move. Never attempt to 
move the heater while it is switched on! 

 

Observe  the  minimum  safe  distance  between  the  heater  body  and  inflammable       
surfaces and objects when mounting. 

 

Please refer to Table 1 for the recommended positioning of the heater with regards to 
minimum distances. Do not install the heater in a corner! 

 

Keep out of the reach of children. 

 
1.          Please refer to  Table  1  for  recommended  positioning  of  the  heater.  When 
             hanging  from  a  ceiling  two  chains  of  equal  length  and  gauge  are  required  and 
             should  be selected with fixings that are more than adequate to hold the weight of 
             the heater. If in doubt contact a professional for advice!  
 
2.

Fix the heater assembly to the chains via the hole in the centre of the joining bar as 
shown in Fig. J. and ensure the heater faces directly down when hanging. 

 
3.          Secure the supply cable so it is not resting on the body or obstructing the air-vents. 
 

             Always isolate the heater from the mains supply when adjusting the position.

 

Fig. J 

A s s e m b l i n g   -   T h r e e   S i n g l e   H e a t e r s   J o i n e d

 

 
1.

Take the first heater and lie it face down on a flat surface. 

 
2.

Take the second and third heaters and position them face down and parallel to the first. 

 
3.

Push the M8 bolts (used to hold the wall brackets through the hole in the brackets on the rear heaters and slide a shake-proof washer on all 
the threads from the protruding side. 

 
4.

Slide the joining bars on each bolt and fit a washer and nut – do not fully tighten at this point. 

 
5.

Position the second heater so it’s parallel to the first and sitting flat. 

 
6.

Take the third heater and a joining bar. Push a bolt and washer through the end hole and place a serrated washer on the other side. Push 
the bolt through the bracket hole on heater. Repeat on opposite side and secure with a washer and nut – do not fully tighten at this point. 

 
7.

Position the third heater so it’s parallel to the second. 

 
8.

Line-up the bars of the first heater with the brackets of the second heater – they should go on the inside faces like heater one. 

 
9.

Line-up the bars of the third heater with the brackets of the second heater – these should go on the outside faces like heater three. 

 
10.

Push a bolt from the back of the joining bars through the holes putting a serrated washer on each side of the heater bracket. 

 
11.

Fit a washer and nut to both sides and providing the assembly is sitting flat, fully tighten both sides and also the nuts of the first and third 
heaters to the joining bars. 

 
12.         The heater is now ready for mounting or hanging.

 

W a l l   M o u n t i n g - T h r e e   S i n g l e   H e a t e r s   J o i n e d  

 

When three Sorrento IP heaters are joined together they can be mounted in a horizontal or vertical manner as the emitter is a universal burning 
type. 

 

When wall mounting three Sorrento IP heaters joined together in a horizontal manner, do not position the heater at an angle more than 80° and 
less than 60° as shown in Fig. K. 

 

When vertically mounting three Sorrento IP heaters joined together, ensure the mounting surface is angled so the heater projects downwards - 
see Fig. C on Page. 3. Do not position the heater at an angle more than 45° and less than 30° to the horizontal as shown. Position the heater so 
the cords are exiting the terminal box pointing down. 

 

Always allow the heater to cool before attempting to reposition/move. Never attempt to move the heater while it is switched on!

 

 

Observe the minimum safe distance between the heater body and inflammable surfaces and objects when mounting.

 

Summary of Contents for SORRENTO IP SINGLE SOR 210IP

Page 1: ...rew Fig T from the side reflector and lift it up away from the heater to remove it Repeat at opposite end to remove other side reflector 8 The lamp the wires should be pulled out of the side slots and the lamp can be lifted up completely Fig U The wires should be gently pulled so they come out from behind the reflector 9 The lamp should now be removed from the heater as shown in Fig V 10 Refit the...

Page 2: ...0 4 0 8 7 17 4 2 0 0 5 1 0 430 x 460 x 402 6 8 IP24 SOR 210IP x 3 230 3 x 1 0 3 0 4 3 13 0 2 5 0 5 1 0 430 x 693 x 402 10 2 IP24 SOR 215IP x 3 230 3 x 1 5 4 5 6 5 19 6 2 5 0 5 1 0 430 x 693 x 402 10 2 IP24 SOR 220IP x 3 230 3 x 2 0 6 0 8 7 26 1 2 5 0 5 1 0 430 x 693 x 402 10 2 IP24 I n s t a l l a t i o n Al l C o n f i g u r a t i o n s Warning this appliance must be connected to an earthed suppl...

Page 3: ...be wall mounted in a horizontal manner or vertical manner or hung from a ceiling from chains not supplied When wall mounting the Sorrento IP heater in a horizontal manner do not position the heater at an angle more than 90 and less than 30 as shown in Fig A When vertically mounting the Sorrento IP heater ensure the mounting surface is angled so the heater projects downwards see Fig C Do not positi...

Page 4: ...ts Always isolate the heater from the mains supply when adjusting the position 5 C e i l i n g H a n g i n g T w o S i n g l e H e a t e r s J o i n e d When two Sorrento IP heaters are joined they can be hung from a ceiling from chains Always allow the heater to cool before attempting to reposition move Never attempt to move the heater while it is switched on Observe the minimum safe distance bet...

Reviews: