background image

Mist level is set too low for 
the room size

1. Adjust to maximum mist
2. Close door or windows to 
     reduce air ventilation, or 
     change to a smaller room

Poor humidification

Air inlet is blocked

Humidifier should be placed 
on a hard flat surface, 2 feet 
above the floor, 12 inches 
away from the wall

Low indoor temperature 
leads to liquefaction

Raise the room temperature 
to 25°C / 77°F

Tap water may contain too 
much minerals

Replace with filtered or 
distilled water or use a 
TaoTronics Demineralization 
Cartridge

White dust appears or the 
black coating on the base 
flakes off

Clean the unit

1. Clean the humidifier as 
     instructed
2. Leave the empty and 
    opened water tank in a 
    cool place for 12 hours 
    without the tank cap 
    attached

Strange Odor

Water is going down to the 
water reservoir

This is normal while it is 
working

Strange water noise

Unit works for too long

Power off and place in a 
well-ventilated place for 10 
minutes 

Humidifier is getting too hot

This product is covered with TaoTronics product and labor warranty for 12 months from the 

date of its original purchase. You will be given a warranty extension of 18 months if the 

product is registered on our website (www.taotronics.com).

Any defective part will be, at the discretion of 

SUNVALLEYTEK INTERNATIONAL INC.

 , repaired 

or replaced at no charge if the appliance has not been tampered with and has been used 

according to these printed directions.

If any problems occur, please contact TaoTronics support (support@taotronics.com) immedi-

ately to launch a warranty claim. Specify model number and your Amazon order number. Our 

Consumer Service Representative will respond within 1 business day, advise you how to 

correct the problem yourself, or instruct you on how to return the defective unit back to us for 

repair or replacement.

We can only provide after sales service for products that are sold by TaoTronics or TaoTronics 

authorized retailers and distributors. If you have purchased your unit from a different place, 

please contact your seller for return and warranty issues.

PLEASE CONTACT US BEFORE RETURNING THIS PRODUCT TO THE STORE.

EMAIL TAOTRONICS CUSTOMER CARE FOR PROBLEMS AND QUESTIONS. 

WE WILL RESPOND WITHIN 1 BUSINESS DAY.

WARRANTY

CONTACT / TAOTRONICS CUSTOMER CARE

E-mail: 

support@taotronics.com(US)

support.ca@taotronics.com(CA)

support.uk@taotronics.com(UK)

Tel: 

1-888-456-8468 (Monday-Friday: 9:00 – 17:00 PST)

Website: 

www.taotronics.com

16

15

Summary of Contents for TT-AH024

Page 1: ...e about the EU Declaration of Conformity https www taotronics com pages user manual www taotronics com Register to extend your 18 months warranty by visiting taotronics com warranty support taotronics com US support ca taotronics com CA support uk taotronics com UK 03 19 2020 TT AH024_V2 4_EN ASIA PACIFIC E mail support jp taotronics com JP JP Importer 株式会社SUNVALLEY JAPAN Address 104 0032 東京都中央区八丁...

Page 2: ... On Off and Mist Adjustment Low Water Protection Auto Shut off the Humidifier CLEANING AND MAINTENANCE Caution Daily Maintenance Weekly Maintenance Scale Removal Instructions Disinfecting Instructions Clean the Dustproof Sponge End Of Season Care and Storage TROUBLESHOOTING GUIDE WARRANTY TAOTRONICS CUSTOMER CARE CONTENTS 01 01 06 08 10 13 15 07 16 16 06 02 03 04 05 08 09 09 10 10 10 10 11 12 12 1...

Page 3: ...product Under no circumstances shall there be liability for any loss direct indirect or incidental or consequential damage arising out of or in connection with the use of the product SAFETY INSTRUCTIONS The humidifier was made with safe and environmental protection materials it has been certified and complied with the requirement of sale regions related regulations or laws IMPORTANT Please read an...

Page 4: ...ith wet hands 2 DO NOT direct the mist nozzle against the wall 1 DO NOT use your hand or any other object to cover the nozzle while the unit is on to avoid damaging the product or causing injury 2 DO NOT clean the unit while it is connected to a power source or while it is on 1 DO NOT move or tilt the humidifier while it is in operation 2 The most comfortable environmental humidity is between 40 6...

Page 5: ...attempt to repair or adjust any electrical or mechanical functions on this humidifier Doing so will void your warranty 1 x TaoTronics Humidifier Model TT AH024 1 x Cleaning Brush 1 x Dustproof Sponge 1 x Thank You Card 1 x User Manual TT AH024 AC 100 120V 50 60Hz Min 15W Max 25W 4 0L 1 06Gal Min 60ml h Max 300ml h 12 50h 20 40m 215 430ft 27dB 258 x 164 x 338mm 10 2 x 6 5 x 13 3in 1350g 47 6oz Mode...

Page 6: ...fill the tank with clean and cool water only 2 Attach the tank cap and place the tank back onto the base Please make sure it fits together securely so that water can go from the tank to the reservoir 5 1 2 3 4 1 If tap water is too hard it is recommended to use filtered or distilled water to avoid white dust DO NOT use hot water 2 DO NOT add any essential oils or medicinal tablets into the water t...

Page 7: ...ting and the LED indicator will become red It is designed for safety to prevent the humidifier from possibly overheating and damaging the atomizer CLEANING AND MAINTENANCE Caution 1 DO NOT submerge the base in water 2 Make sure water does not enter the base through the air outlet air inlet or the control knob 3 DO NOT wash any part of this humidifier in dish washer which will damage the humidifier...

Page 8: ...r disinfecting see below is gone Disinfecting Instructions 1 Follow steps 1 2 of the previous section on scale removal 2 Fill the water tank half full Add in tsp of bleach Place the tank cap back on Swish the solution around in tank Place the tank on the base The bleach solution will enter and disinfect the water reservoir as well as the other components Set still for 15 20 minutes 3 Follow steps ...

Page 9: ...et too low Adjust to maximum mist Mineral buildup on the atomize Feel if any air comes out from the nozzle If yes then clean water scale on the atomizer as instructed The base might be overfilled Remove the tank empty the base and place the filled tank on the empty base Tank leakage Tank may be damaged Check for possible cracks in the tank replace if necessary Tank cap is not tightened securely Ti...

Page 10: ...y extension of 18 months if the product is registered on our website www taotronics com Any defective part will be at the discretion of SUNVALLEYTEK INTERNATIONAL INC repaired or replaced at no charge if the appliance has not been tampered with and has been used according to these printed directions If any problems occur please contact TaoTronics support support taotronics com immedi ately to laun...

Page 11: ...s should not be disposed of with other household waste at the end of their working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this prod...

Page 12: ...尺寸 150 200mm 装订成册 材质 封面128克铜版纸 内页80克书纸 Model TT AH024 ...

Reviews: