background image

13

14

TROUBLESHOOTING GUIDE

1. If the information listed in the troubleshooting guide can’t solve your 
    problem, please email us for help.
2. Failure to keep this unit clean from mineral deposits may affect operation 
    of this unit. 
3. Customer failure to follow these instructions may void the warranty.

1

2

1. Spring  
2. Sealing ring

Not enough water
inside the tank

Refill and reinstall the
water tank

The LED Indicator is
yellow but no mist or
little mist is produced

Mist level is set too low

Adjust to maximum mist

Mineral buildup on the 
atomizer

Feel if any air comes out
from the nozzle. If yes, then
clean water scale on the
atomizer as instructed

The base might be
overfilled

Remove the tank, empty
the base and place the
filled tank on the empty
base

Tank leakage

Tank may be damaged

Check for possible
cracks in the tank, 
replace if necessary

Tank cap is not
tightened securely

Tighten the tank cap

     Spring stuck

Ensure the      spring is 
properly secured to the
tank bottom allowing
water to pass through to
the base.

1

1

     Sealing ring was not 
installed on tank cap

Install the      sealing ring
on the tank cap, please
contact us if it is missing

2

2

Mist level is set too high
for the room size

Air inlet is blocked

Humidifier should be
placed on a hard flat
surface, 2 feet above the
floor, 12 inches away from
the wall. Point nozzle away
from wall or window

Low indoor temperature 
leads to liquefaction

Raise the room
temperature to 25°C / 77°F

Mist height is low, 
damping surrounding
desk or floor.
Condensation forms
around humidifier or on
windows and walls

1. Check if the room is too 
    humid and adjust to
    lower mist. 40%-60%
    works best
2. Open door and
    windows, or change to
    a larger room

Problem

Possible Cause

Solution

Unit not plugged in

No power from power
outlet

Did not turn on the unit

Ensure unit is properly 
plugged in

Try another power outlet

Rotate the Control Knob
clockwise to turn on the unit

LED indicator is off

Ensure the      Spring is 
secured properly to the
tank bottom allowing
water to pass through
to the base

1

No water in the water 
reservoir

LED indicator stays red

Summary of Contents for TT-AH026

Page 1: ...110x160mm 128g 80...

Page 2: ...Conformity https www taotronics com pages user manual www taotronics com MODEL TT AH026 ULTRASONIC COOL MIST HUMIDIFIER User Manual Register to extend your 18 months warranty by visiting taotronics c...

Page 3: ...dd water Power On Off and Mist Adjustment Low Water Protection Auto Shut off the Humidifier CLEANING AND MAINTENANCE Caution Daily Maintenance Weekly Maintenance Scale Removal Instructions Disinfectin...

Page 4: ...oduct Under no circumstances shall there be liability for any loss direct indirect or incidental or consequential damage arising out of or in connection with the use of the product SAFETY INSTRUCTIONS...

Page 5: ...he unit with wet hands 2 DO NOT direct the mist nozzle against the wall 1 DO NOT use your hand or any other object to cover the nozzle while the unit is on to avoid damaging the product or causing inj...

Page 6: ...ist Allow the humidifier to completely cool down before cleaning 2 DO NOT attempt to repair or adjust any electrical or mechanical functions on this humidifier Doing so will void your warranty 1 2 1 2...

Page 7: ...ther securely so that water can go from the tank to the reservoir 5 1 2 3 4 1 If tap water is too hard it is recommended to use filtered or distilled water to avoid white dust DO NOT use hot water 2 D...

Page 8: ...event the humidifier from possibly overheating and damaging the atomizer CLEANING AND MAINTENANCE Caution 1 DO NOT submerge the base in water 2 Make sure water does not enter the base through the air...

Page 9: ...reservoir and water tank until the smell of vinegar for scale removal or bleach solution for disinfecting see below is gone Disinfecting Instructions 1 Follow steps 1 2 of the previous section on sca...

Page 10: ...perly secured to the tank bottom allowing water to pass through to the base 1 1 Sealing ring was not installed on tank cap Install the sealing ring on the tank cap please contact us if it is missing 2...

Page 11: ...rranty extension of 18 months if the product is registered on our website www taotronics com Any defective part will be at the discretion of SUNVALLEYTEK INTERNATIONAL INC repaired or replaced at no c...

Page 12: ...should not be disposed of with other household waste at the end of their working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate thes...

Reviews: