PRSU Series, Operating Instructions Manual (Revision 1.0) 

 

 
Safety Indications 

 

Intended 
Application

 

 

 

The safety relays PRSU/2, PRSU/4 and PRSU/5 are intended for the use with: 
 

 

Single or dual-channel capability safety mats. 

 

 

Single or dual-channel capability sensing edges, bumpers or ribbon 
switches. 

 

 

 
Operator and asset protection are only guaranteed if the safety relay is  
operated  according  to  its  intended  purpose  and  within  the  limits  stated  in  its 
specification. 
 

 

 
Please pay attention to the following points: 

 

 
Safety Warning 
 
 
 
 
 
 
 
 
 

 

 The device must be wired and operated by specialized staff who are  

familiar with the current regulations for safety at work and accident  
prevention and who have read this manual´s content in full. Installation,  
assembly and maintenance of electrical equipment is only permitted by  
specialized staff. 
 

 Pay attention to valid regulations, particularly in reference to preventative 

measures. 
 

 Any repairs or modifications that are attempted outside of a Tapeswitch  

factory, or by personnel that are not authorized by the manufacturer may  
render the unit unreliable to serve as a safety component and should be  
replaced immediately. Unauthorized modification will immediately void any 
warranty. 
 

 Avoid mechanical vibrations more than 5g/33 Hz during transportation,  

installation and operation. 
 

 The unit should be panel mounted in an enclosure rated IP 54 or better.  

Dust and dampness could lead to malfunction. 
 

 Adequate fuse protection must be provided on all output contacts  

with capacitive and inductive loads. 

 

 

Summary of Contents for PRSU/2

Page 1: ...lants who are familiar with the safety instructions and safety regulations Skilled personnel who build install maintain and operate safety equipment in plants and machinery Symbol Key These operating...

Page 2: ...regulations for safety at work and accident prevention and who have read this manual s content in full Installation assembly and maintenance of electrical equipment is only permitted by specialized s...

Page 3: ...voltage of 24VDC or 24VAC This model features two normally open safety relays that are triggered by the Sensor Monitoring terminals S11 S12 S21 S22 Terminals Description A1 Power input 24VDC or 24VAC...

Page 4: ...relays that are triggered by the Sensor Monitoring terminals S11 S12 S21 S22 This model also features an additional normally closed auxiliary relay not for safety use Terminals Description A1 Power in...

Page 5: ...ty relays that are triggered by the Sensor Monitoring terminals S11 S12 S21 S22 This model also features an additional normally closed auxiliary relay not for safety use Terminals Description A1 Power...

Page 6: ...or more information After the RESET signal is received and the monitored switch is in the unactuated state the relay contacts 13 14 23 24 will close Device Startup Verification PRSU 4 PRSU 5 Before cr...

Page 7: ...application will require only a single PRSU 2 PRSU 4 or PRSU 5 the following rule of thumb guidelines can be used Recommended Application Limits Product Type Maximum Area Maximum Length ControlMat Arm...

Page 8: ...ch on the rear of the unit for DIN Rail attachment Electrical Connections Wire the device based on which of the following options best suits the target application RESET Mode Control Wiring 1 Automati...

Page 9: ...closure is broken and a RESET signal is manually generated by the operator via a mechanical N O pushbutton or switch 3 Conditional In this operating mode the RESET signal cannot propagate unless all o...

Page 10: ...nergize Warning For this configuration to work as intended the series resistance between each end of the sensor s conductors cannot exceed 10 Additionally the short circuit resistance between both of...

Page 11: ...no terminal of the device is connected to a live voltage before continuing 2 Unscrew terminals A1 and A2 from the device before removing any other connections 3 One at a time free connections from the...

Page 12: ...es In cases where either one or both Channel LEDs is OFF during normal operation please verify that the device is properly wired If the problem persists the device is no longer capable of service Reti...

Page 13: ...47 5 1 AC 15 3 A DC 13 3 A Max Switching Capacity 1500 VA resistive load Mechanical Lifetime 107 switching cycles Creeping Distance and Clearance EN 50178 at pollution grade 2 over voltage category 3...

Page 14: ...rical Lifetime 105 switching cycles DC 24V 2A 105 switching cycles DC 24V 2A Creeping Distance and Clearance EN 50178 at pollution grade 2 over voltage category 3 250V Basis isolation over voltage cat...