4. OPTIONS
IOM manual active pulsation dampeners
20
4.
OPTIONS
4.1.
DTB series
The DTB series equipped with fully pneumatic control system
“Guardian”
is perfect choice
when the diaphragm rupture has to be immediately detected in order to avoid product
leak to the environment. When rupture is detected the pump is automatically stopped
and an alarm can be generated
. For detailed guidelines see „Guardian system” IOM
manual.
Available for sizes:
➢
DTB20, 25, 30
➢
DTB50, 70, 80
➢
DTB100, 120, 125
➢
DTB200, 220, 225
➢
DTB400, 420, 425
4.2.
DTF series
The DTF series pulsation dampeners are special execution used widely with the TF series AODD pumps.
Reinforcement steel plates are used to make the device more robust. Thanks to this, DTF dampeners
can work within higher operating pressures.
The maximum air supply pressure:
➢
DTF50, DTF70, DTF100 and DTF120
–
16 bar,
➢
DTF220 and DTF420
–
14
bar,
➢
DTF200 and DTF400
–
12 bar.
Keep in mind that TF pumps are supplied with air through the pressure booster. As a
result the air directed to the pump can be multiplied up to 2 times. For detailed
information see TF series IOM manual.