7.
MAINTENANCE
Tapflo LPX series
25
7.
MAINTENANCE
7.1.
Important safety information
DANGER!
The pump contains internal moving parts. DO NOT put hands or fingers into
the pump body ports or drive area at any time during operation. To avoid serious injury,
DO NOT install, clean, service, or repair the pump unless all power is off and locked out.
Before detaching port connections to the pump:
Close suction and discharge valves.
Drain pump and clean or rinse, if necessary.
Disconnect or shut off the electrical supply and lock out all power.
7.2.
Lubrication
Fig. 26:
Lubrication points
Tab. 1:
Callout table for figure 26
30
Oil Fill Breather
31
Oil Level Check Plug, Sight Glass
32
Oil Drain Plug
33
Grease Fittings
34
Grease Cleanout Plug
7.2.1.
Drive lubrication
Refer to the manufacturer’s manual shipped with the drive for proper drive lubrication and
frequency.
7.2.2.
Gear oil
CAUTION!
Each pump is shipped from the factory with the gearbox sealed. Prior to
operation, check the oil level and replace the uppermost oil drain plug with the supplied
oil fill breather, at the location of item 30 in Figure 26.
Refer to the table below for the required capacity per pump model as shown.
Change the oil every 1000 hours.
Summary of Contents for LPX Series
Page 59: ...9 PARTS LISTS Tapflo LPX series 59 9 3 Model 25 1 to 50 1 Pump Parts B exploded view ...
Page 61: ...9 PARTS LISTS Tapflo LPX series 61 9 5 Model 50 2 to 100 1 Pump Parts A exploded view ...
Page 63: ...9 PARTS LISTS Tapflo LPX series 63 9 7 Model 50 2 to 100 1 Pump Parts B exploded view ...
Page 69: ...Tapflo LPX series 69 ...