Illustrative images
Remote Cable 18 AWG
Circuit Breaker
50mm² (1/0 A
WG)
6mm² (9 AWG)
50mm² (1/0 A
WG)
6mm² (9 AWG)
Head Unit
Other Amplifier
IN
OUT
RCA Cables
Taramps
GND
12V
SPEAKER
IN
OUT
MONITOR
0.2
GAIN
4
BASS BOOST
BOOST
+10
0
dB
FREQ.
55
35
Hz
Hz
Hz
LOW PASS
90
10
CROSSOVER
HIGH PASS
10K
90
V
11
Positive / negative power supply cable ___________________
__Min. 4 AWG / Max.1/0 AWG
Output cables wire gauge_______________________________
_________________9 AWG
Remote cable ___________________
______________________________________ 18 AWG
Protection fuse or circuit breaker
____________________________________________200A
Calculated considering a maximum length of 4m. Distance greater than this, you will need to
increase the cable gauges.
Installation
Recommended wire gauge & fuse
CAUTION: All connections to power supply, input and output connectors must
be carried out only with amplifier off.
CAUTION
Using wire gauges below the recommendation will result in power loss and
overheating of wiring.
Check polarity and never reverse power supply cables due to the risk of damage to the amplifier.
It is compulsory to install a protection fuses or circuit breakers as close as possible from batteries.
CAUTION
This equipment is not suitable
for use in places where children may be present.
CAUTION
Examples of connections in the power supply input.
Note: Required battery bank capacity: At least 200Ah
The entire aluminum surface of
the amplifier serves as a heat
sink. The usually working temperature is 65°C. So,
avoid contact with this surface when the amplifier is
in use.
CAUTION