background image

Tarana Wireless, Inc. Proprietary and ©2021.  All rights reserved.  vG1-RN-2021-01  

G1 RN Manual — 4 

 

 

 

 

 

General Hazards 

Topic 

Explanation 

Chassis Earthing 

The G1 chassis earth must be connected directly to the DC supply system earthing conductor, or to a bonding jumper from an earthing 
terminal bar, or bus to which the DC supply system earthing is connected. 

Protection from RF 
Exposure 

When installing, servicing or inspecting an antenna always comply with the following: 

 

Locate the antenna such that it does not infringe the RF Exposure Limit Distance, relating to the Compliance Boundary General Public. 

 

Stay aware of the potential risk of RF exposure and take appropriate precautions. 

 

Do not stand in front of or look into an antenna without first ensuring the associated transmitter or transmitters are switched off.  

 

At a multi-antenna site ask the site owner or operator for details of other radio services active at the site and for their 
requirements/recommendations for protection against potentially harmful exposure to RF radiation.  

 

When it is not possible to switch transmitters off at a multi-antenna site and there is potential for exposure to harmful levels of RF 
radiation, wear a protective suit. 

Fiber Optic Cables 

 

Handle optical fibers with care. Keep them in a safe and secure location during installation. 

 

Do not attempt to bend them beyond their minimum bending radius. 

 

Protect/cover unconnected optical fiber connectors with dust caps. 

Grounding Connections  Reliable grounding of the G1 chassis must be maintained. 
Mains Power Supply 
Routing 

G1 DC power is not to be routed with any AC mains power lines. They are also to be kept away from any power lines which cross them. 

Maximum Ambient 
Temperature 

The maximum ambient temperature for the G1 product is 55 degrees C. To ensure correct operation and to maximize long term component 

reliability, ambient temperatures must not be exceeded. Operational specification compliance is not guaranteed for higher ambients.  G1 
should be mounted in such a way as to permit the vertical free flow of air through its cooling fins. 

Mechanical Loading 

When installing the G1 on a tower, ensure that the tower is securely anchored. Ensure that the additional loading of devices will not cause any 
reduction in the mechanical stability of the tower. 

Power Supply 
Connection 

G1 operates from a nominal -48 VDC power supply. 

Power Supply 
Disconnect 

An appropriate power supply disconnect device should be provided as part of the installation. 

Rack Mount 
Temperature 
Considerations 

G1 is designed to operate in an outdoor environment with no significant obstructions in front of the radome.  Do not install G1 in a closed or 

multi-unit rack assembly, because such a closed rack would impede the propagation of the RF signals. The maximum ambient temperature 
applies to the immediate operating environment of the G1 product. 

 

Summary of Contents for G1 RN

Page 1: ...TaranaG1RNManual ...

Page 2: ...a Statements 7 Deployment in the European Union CE Mark 8 Preparation 10 Tools Required 10 Tarana Hardware and Peripherals 10 Customer Supplied Equipment 10 Physical Installation 11 Preparing the RN 11 Wall or Surface Mounting the Elevation Bracket 12 Pole Mounting the Elevation Bracket 12 Installing the RN 13 Powering Up the RN 14 Warranty 15 NOTE For the most up to date instructions please downl...

Page 3: ...port when no fiber is connected therefore avoid exposure to laser radiation and do not stare into open apertures FCCInformation The FCC occupational controlled limit for maximum permissible exposure MPE is 5 mW cm2 It is estimated that the maximum power density at the radome is 1 25 mW cm2 which is below the FCC MPE limit Since the power density for an occupational controlled environment is less t...

Page 4: ... to this equipment that are not in accordance with the provisions of this User Guide the Installation Guide or other supplementary documentation may result in personal injury or damage to the equipment and may void the equipment warranty AVERTISSEMENT Tout réglage ou modification faits à cet équipement hors du cadre édicté par ce guide d utilisation ou par toute autre documentation supplémentaire ...

Page 5: ... to bend them beyond their minimum bending radius Protect cover unconnected optical fiber connectors with dust caps Grounding Connections Reliable grounding of the G1 chassis must be maintained Mains Power Supply Routing G1 DC power is not to be routed with any AC mains power lines They are also to be kept away from any power lines which cross them Maximum Ambient Temperature The maximum ambient t...

Page 6: ... 2013 08 IP X7 EN 62368 1 2014 2nd Edition IEC EN 60950 22 Immunity EN61000 4 5 Level 4 AC Surge Immunity EN61000 4 4 Level 4 Electrical Fast Transient Burst Immunity EN61000 4 3 Level 4 EMC Field Immunity EN61000 4 2 Level 2 ESD Immunity Radio Approvals FCC Part 15 Subpart E 15 407 RSS 192 RSS 197 RSS 199 EN 302 326 2 EN 302 502 EMI and susceptibility FCC part 15 207 15 209 ICES 003 RSS Gen CAN I...

Page 7: ...ergy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correc...

Page 8: ...ce including interference that may cause undesired operation of the device Le produit final doit être installé par un professionnel Cet appareil numérique de la classe B est conforme à la norme NMB 003 du Canada IC avertissements d exposition RF Pour satisfaire les exigencies d IC en ce qui a trait aux expositions aux RF pour RF dispositifs de transmission les distances suivantes doit être mainten...

Page 9: ...s Tarana Wireless systems are designed to be operated as to avoid contact with the antennas by the end user It is recommended to install the system in a location where the antennas can remain at least a minimum distance as specified from the user in accordance to the regulatory guidelines which are designed to reduce the overall exposure of the user or operator To meet radiation exposure requireme...

Page 10: ... Ova oprema je u skladu s osnovnim zahtjevima i drugim relevantnim odredbama Direktive 2014 53 EU English This equipment is in compliance with essential requirements and other relevant provisions of Directive 2014 53 EU Български Bulgarian Това оборудване е в съответствие с основните изисквания и съответващите разпоредби на Директива 2014 53 EU Cesky Czech Toto zařízení je v souladu se základními ...

Page 11: ...are and Peripherals RN radio unit RN mounting kit o 1pcs RN chassis bracket o 1pcs RN elevation Bracket o 8pcs M5 flanged head screw with thread lock o 2pcs Wormdrive clamps Single hole ground lug Passive PoE injector with power cord 1 m Ethernet cable Customer Supplied Equipment Ethernet cable shielded CAT5e CAT6 RJ45 connectors Grounding wire 14 AWG Earthing hardware Lightning and surge protecti...

Page 12: ...hat will not damage the plastic radome Step 2 Place the chassis bracket onto the back of the RN and locate it onto the 4 threaded holes Step 3 Using an 8mm hex socket install the four screws and gradually torque them in a crossing pattern to the specified torque value of 6 N m 4 5 ft lb Step 4 Partially install one screw on each of the elevation attachment tabs of the chassis bracket in the locati...

Page 13: ... in diameter can be used with the bracket without issue Do not attempt to use fasteners smaller than 6mm and never modify the elevation bracket by drilling for larger than 8mm fasteners as it will damage the corrosion protection of the finish Step 3 Install the elevation bracket with its elevation tabs facing outward and oriented as shown PoleMountingtheElevationBracket Step 1 Route the opened scr...

Page 14: ...nd around the terminated RJ45 connector and cable Step 5 Carefully plug the RJ45 connector into the RN making sure there is an audible click made by the connector properly seating into RJ45 receptacle on the main PCB inside the RN enclosure If the click is not heard a slight pull on the Ethernet cable is sufficient to check if the cable has been properly seated or not DO NOT FORCIBLY pull on the E...

Page 15: ...rana POE injector apply power to Ethernet cable Step 2 Verify LED operation Step 3 Once the RF link is established optimize alignment using RN local WebUI Step 4 Torque the four screws used on the elevation attachment tabs to 6 N m 4 5 ft lb Step 5 Run final checks a Authentication b Internet connectivity c Internet speed test ...

Page 16: ...r implied conditions representations and warranties including without limitation any implied warranty or condition of merchantability fitness for a particular purpose non infringement satisfactory quality non interference accuracy of informational content or arising from a course of dealing law usage or trade practice are hereby excluded to the extent allowed by applicable law and are expressly di...